The provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021)., Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus)., Spanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM., Peer reviewed
DOI: http://hdl.handle.net/10261/248554
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/248554
HANDLE: http://hdl.handle.net/10261/248554
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/248554
Ver en: http://hdl.handle.net/10261/248554
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/248554
No hay resultados en la búsqueda
×
1 Versiones
1 Versiones
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/248554
Dataset. 2021
DATA FOR THE PAPER “OPTICAL AND VISUAL QUALITY OF REAL INTRAOCULAR LENSES PHYSICALLY PROJECTED ON THE PATIENT’S EYE”
Digital.CSIC. Repositorio Institucional del CSIC
- Benedi, Clara
- Viñas, María
- Lago, Carmen M.
- Aissati, Sara
- Castro, Alberto de
- Dorronsoro, Carlos
- Marcos, Susana
The provided Data Set contains an Excel file with the results obtained in the study entitled “Optical and visual quality of the real intraocular lenses physically projected on the patient’s eye”, by C. Benedi-Garcia, M. Vinas, C. M. Lago, S. Aissati, A. de Castro, C. Dorronsoro, S. Marcos, to be published in Biomedical Optics Express (2021)., Visual simulators aim at evaluating vision with ophthalmic corrections prior to prescription or implantation of intraocular lenses (IOLs) in the patient’s eye. In the present study, we present the design, implementation, and validation of a new IOL-in-cuvette channel in an Adaptive Optics visual simulator, which provides an alternative channel for pre-operative simulation of vision with IOLs. IOL-in-cuvette is projected to the pupil’s plane of the subject by using a Rassow system. A second lens, the Rassow lens, compensates for an IOL of 20 D while other powers can be corrected with a Badal system in a 5 D range. The new channel was evaluated by through-focus (TF) optical quality on an artificial eye on bench, and by TF visual acuity in patients, with various IOL designs (monofocal, diffractive trifocal, and refractive extended depth of focus)., Spanish Government FIS2017-84753R. Spanish Government Predoctoral Grant FPU16/01944 to SA. ERC AdG-2018-833106 SILKEYE to SM., Peer reviewed