Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

A Customized Light Sheet Microscope to Measure Spatio-Temporal Protein Dynamics in Small Model Organisms

  • Ripoll Lorenzo, Jorge
  • Rieckher, Matthias
  • Kyparissidis-Kokkinidis, Ilias
  • Zacharopoulos, Athanasios
  • Kourmoulakis, Georgios
  • Zacharakis, Giannis
  • Tavernarakis, Nektarios
We describe a customizable and cost-effective light sheet microscopy (LSM) platform for rapid three-dimensional imaging of protein dynamics in small model organisms. The system is designed for high acquisition speeds and enables extended time-lapse in vivo experiments when using fluorescently labeled specimens. We demonstrate the capability of the setup to monitor gene expression and protein localization during ageing and upon starvation stress in longitudinal studies in individual or small groups of adult Caenorhabditis elegans nematodes. The system is equipped to readily perform fluorescence recovery after photobleaching (FRAP), which allows monitoring protein recovery and distribution under low photobleaching conditions. Our imaging platform is designed to easily switch between light sheet microscopy and optical projection tomography (OPT) modalities. The setup permits monitoring of spatio-temporal expression and localization of ageing biomarkers of subcellular size and can be conveniently adapted to image a wide range of small model organisms and tissue samples., MR, GZ and AZ acknowledge funding from the Projects “Skin-DOCTor” Grant No. 1778 and “Neureka!” Grant No. LSF7-341 implemented under the "ARISTEIA" and "Supporting Postdoctoral Researchers" Actions respectively, of the "OPERATIONAL PROGRAMME EDUCATION AND LIFELONG LEARNING", (http://www.espa.gr/en/pages/staticOPEducationandLifelongLearning.aspx), which is co-funded by the European Social Fund and National Resources and from the EU Marie Curie Initial Training Network “OILTEBIA”, Grant No. PITNGA-2012-317526 (http://ec.europa.eu/research/mariecurieactions/, http://gdo.uc3m.es/oiltebia/index. php?option = com_content&view = frontpage). JR acknowledges support from EC FP7 CIG grant HIGHTHROUGHPUT TOMO PICIG12-GA-2012-333632, (http://cordis.europa.eu/projects/333632), and Spanish MINECO grant MESO-IMAGING FIS2013-41802-R, (https://sede.micinn.gob.es/). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Optoacoustic response of gold nanorods in soft phantoms using high-power diode laser assemblies at 870 and 905 nm

  • Leggio, Luca
  • Gawali, Sandeep Babu
  • Gallego Cabo, Daniel
  • Rodríguez Hervás, Sergio
  • Sánchez Rodas, Miguel
  • Carpintero del Barrio, Guillermo
  • Lamela Rivera, Horacio
In the present paper we show the optoacoustic (OA) response of two solutions of gold nanorods dispersed in distilled water (0.8 mg/ml) and hosted in tissue-like phantoms by using small arrays of HPDLs at 870 and 905 nm as excitation sources. The HPDLs are coupled to a 7-to-1 optical fiber bundle with output diameter of 675 mu m. Each solution of gold nanorods exhibits an absorption peak close to the operating wavelength, i.e. similar to 860 nm and similar to 900 nm, respectively, to optimize the generation of OA signals. The phantoms are made of agar, intralipid and hemoglobin to simulate a soft biological tissue with reduced properties of scattering. Three 3-mm diameter tubes done in the phantoms at different depths (0.9 cm, 1.8 cm, and 2.7 cm) have been filled with gold nanorods. In this way, OA signals with appreciable SNR are generated at different depths in the phantoms. The high OA response exhibited by gold nanorods suggests their application in OA spectroscopy as exogenous contrast agents to detect and monitor emerging diseases like metastasis and arteriosclerotic plaques., This research is part of OILTEBIA project (Optical Imaging and Laser TEchniques for BIomedical Applications), whch is an Initial Training Network (ITN) funded by the European Community's Seventh Framework Programme, Grant Agreement Number 317526.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Phase-Retrieved Tomography enables Mesoscopic imaging of Opaque Tumor Spheroids

  • Ancora, Daniele
  • Di Battista, Diego
  • Giasafki, Georgia
  • Psycharakis, Stylianos E.
  • Liapis, Evangelos
  • Ripoll Lorenzo, Jorge
  • Zacharakis, Giannis
We present a new Phase-Retrieved Tomography (PRT) method to radically improve mesoscopic imaging at regimes beyond one transport mean-free-path and achieve high resolution, uniformly throughout the volume of opaque samples. The method exploits multi-view acquisition in a hybrid Selective Plane Illumination Microscope (SPIM) and Optical Projection Tomography (OPT) setup and a three-dimensional Gerchberg-Saxton phase-retrieval algorithm applied in 3D through the autocorrelation sinogram. We have successfully applied this innovative protocol to image optically dense 3D cell cultures in the form of tumor spheroids, highly versatile models to study cancer behavior and response to chemotherapy. We have thus achieved a significant improvement of resolution in depths not yet accessible with the currently used methods in SPIM/OPT, while overcoming all registration and alignment problems inherent to these techniques., This work was supported by the grants "Skin-DOCTor" (1778) implemented under the "ARISTEIA" Action of the "Operational Programme Education and Lifelong Learning" co-funded by the European Social Fund (ESF) and National Resources, the EU Marie Curie ITN "OILTEBIA" PITN-GA-2012-317526 and the H2020 Laserlab Europe (EC-GA 654148). J.R. acknowledges support from the EC-FP7-CIG grant HIGH-THROUGHPUT TOMO and MINECO grant FIS2016-77892-R. The Authors also acknowledge support from the Institute of Molecular Biology and Biotechnology of the Foundation for Research and Technology - Hellas for the use of the cell culture facilities.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Beam Profile Improvement of a High-Power Diode Laser Stack for Optoacoustic Applications

  • Sánchez Rodas, Miguel
  • Rodríguez Hervás, Sergio
  • Leggio, Luca
  • Gawali, Sandeep Babu
  • Gallego Cabo, Daniel
  • Lamela Rivera, Horacio
Selected papers from Third Conference on Photoacoustic and Photothermal Theory and Applications., Recent advances in high-power diode lasers (HPDLs) technology allow their use as potential sources for optoacoustic (OA) applications, due to their high repetition rates (a few kHz), low costs and sizes. However, some OA applications require pulse energies in the order of mJ that cannot be provided by the only HPDLs (several mu J). The employment of diode laser bars (DLBs) and stacks (DLSs) significantly increases the energy per pulse up to several mJ, but they require more optical elements for collimation in fast and slow axes. In this work, we show an 808 nm DLS emitting optical nanosecond pulses with currents of similar to 200 A and supplied by a customized current driver. We only collimate the beam in the fast axis by disposing the core of 200 mu m optical fibers as collimating lenses along each bar of the stack, and we discuss the improvement of the beam profile. The results demonstrate that the beam profile is notably improved with the optical fiber lenses, and a 6.4 mm x 4.3 mm light spot is obtained by using a conventional focusing lens. Measurements report a total energy per pulse of 630 mu J in the spot, considering a pulse width of 850 ns and a repetition rate of 1 kHz. Finally, we focus the light spot into an absorbing inclusion (graphene oxide) hosted in a semi-transparent phantom to generate and detect high OA signals (similar to 355 mV(pp)). The results achieved demonstrate the capability of our DLS system to be applied in multispectral OA systems with final application in OA endoscopy and microscopy., A special acknowledgment has to be addressed to the ESA for the DLS provided. This research is part of OILTEBIA project (Optical Imaging and Laser TEchniques for BIomedical Applications), which is an Initial Training Network (ITN) funded by the European Community Seventh Framework Programme, Grant Agreement Number 317526.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

In vivo, non-invasive characterization of human bone by hybrid broadband (600-1200 nm) diffuse optical and correlation spectroscopies

  • Konugolu Venkata Sekar, Sanathana
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus
  • Farzam, Parisa
  • Pérez Álvarez, Nuria|||0000-0001-6582-1553
  • Puig, Jordi
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

In vivo, non-invasive characterization of human bone by hybrid broadband (600-1200 nm) diffuse optical and correlation spectroscopies

  • Konugolu Venkata Sekar, Sanathana
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus
  • Farzam, Parisa
  • Pérez Álvarez, Nuria
  • Puig, Jordi
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care., Peer Reviewed, Postprint (published version)
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

In Vivo, Non-Invasive Characterization of Human Bone by Hybrid Broadband (600-1200 nm) Diffuse Optical and Correlation Spectroscopies

  • Konugolu Venkata Sekar, Sanathana|||0000-0003-0912-1282
  • Pagliazzi, Marco
  • Negredo Puigmal, Eugènia|||0000-0001-5298-1734
  • Martelli, Fabrizio
  • Farina, Andrea
  • Dalla Mora, Alberto
  • Lindner, Claus|||0000-0002-9878-037X
  • Farzam, Parisa
  • Pérez-Álvarez, Núria|||0000-0001-6582-1553
  • Puig, Jordi|||0000-0002-4075-0346
  • Taroni, Paola
  • Pifferi, Antonio
  • Durduran, Turgut|||0000-0001-5838-1027
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600-1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Blood flow response to orthostatic challenge identifies signatures of the failure of static cerebral autoregulation in patients with cerebrovascular disease

  • Gregori-Pla, Clara|||0000-0002-6623-0031
  • Mesquita, Rickson C.
  • Favilla, Christopher G.
  • Busch, David R.
  • Blanco, Igor|||0000-0001-7636-1177
  • Zirak, Peyman|||0000-0002-0331-6292
  • Frisk, Lisa Kobayashi
  • Avtzi, Stella|||0000-0002-8893-3969
  • Maruccia, Federica|||0000-0002-3774-7875
  • Giacalone, Giacomo
  • Cotta, Gianluca
  • Camps-Renom, Pol|||0000-0001-6587-6271
  • Mullen, Michael T.
  • Martí-Fàbregas, Joan|||0000-0001-9229-8649
  • Prats Sánchez, Luis Antonio|||0000-0002-3192-4631
  • Martínez-Domeño, Alejandro|||0000-0002-9933-3192
  • Kasner, Scott E.
  • Greenberg, Joel H.
  • Zhou, Chao
  • Edlow, Brian L.
  • Putt, Mary E.
  • Detre, John A.
  • Yodh, Arjun G.
  • Durduran, Turgut|||0000-0001-5838-1027
  • Delgado Mederos, Raquel|||0000-0003-3737-7226
The cortical microvascular cerebral blood flow response (CBF) to different changes in head-of-bed (HOB) position has been shown to be altered in acute ischemic stroke (AIS) by diffuse correlation spectroscopy (DCS) technique. However, the relationship between these relative ΔCBF changes and associated systemic blood pressure changes has not been studied, even though blood pressure is a major driver of cerebral blood flow. Transcranial DCS data from four studies measuring bilateral frontal microvascular cerebral blood flow in healthy controls (n = 15), patients with asymptomatic severe internal carotid artery stenosis (ICA, n = 27), and patients with acute ischemic stroke (AIS, n = 72) were aggregated. DCS-measured CBF was measured in response to a short head-of-bed (HOB) position manipulation protocol (supine/elevated/supine, 5 min at each position). In a sub-group (AIS, n = 26; ICA, n = 14; control, n = 15), mean arterial pressure (MAP) was measured dynamically during the protocol. After elevated positioning, DCS CBF returned to baseline supine values in controls (p = 0.890) but not in patients with AIS (9.6% [6.0,13.3], mean 95% CI, p < 0.001) or ICA stenosis (8.6% [3.1,14.0], p = 0.003)). MAP in AIS patients did not return to baseline values (2.6 mmHg [0.5, 4.7], p = 0.018), but in ICA stenosis patients and controls did. Instead ipsilesional but not contralesional CBF was correlated with MAP (AIS 6.0%/mmHg [- 2.4,14.3], p = 0.038; ICA stenosis 11.0%/mmHg [2.4,19.5], p < 0.001). The observed associations between ipsilateral CBF and MAP suggest that short HOB position changes may elicit deficits in cerebral autoregulation in cerebrovascular disorders. Additional research is required to further characterize this phenomenon. The online version contains supplementary material available at 10.1186/s12883-021-02179-8.