Skip to main content

TRANSDUCTORES AVANZADOS, BIOCHIPS Y PLATAFORMAS DE LECTURA PARA BIOSENSORES DE ALTO RENDIMIENTO, DETECCION DE LIQUIDOS Y MONITORIZACION DE CELULAS

TEC2017-84846-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD POLITECNICA DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Phosphorylcholine-based hydrogel for immobilization of biomolecules. Application to fluorometric microarrays for use in hybridization assays and immunoassays, and nanophotonic biosensing

  • Díaz-Betancor, Zeneida
  • Sanza, Francisco Javier
  • Casquel, Rafael
  • Laguna, María Fé
  • Holgado, Miguel
  • Bañuls Polo, María-José|||0000-0002-2422-7731
  • Puchades, Rosa|||0000-0002-9329-1593
  • Maquieira, Angel|||0000-0003-4641-4957
[EN] An approach is presented for covalent immobilization of biomolecules on an acrylate phosphorylcholine hydrogel. The immobilization and the hydrogel formation take place simultaneously by a thiol-acrylate coupling reaction, induced by UV-light (254nm). The hydrogel is prepared on two polymeric surfaces (the HardCoat protective layer of Blu-Ray discs, and SU-8) and applied to fluorescence microarray and label-free interferometric detection. For the first, Cy5 labeled analytes are used (lambda(em) 635nm) and, for the second, a periodic array of high-aspect ratio nanopillars detects unlabeled analytes by interferometry. Bioavailability of the immobilized probes is demonstrated in labeled assays; for the case of oligonucleotides by discriminating single nucleotide polymorphisms, and, for the case of antibodies, by BSA immunorecognition. The raw hydrogel is employed to detect human C-reactive protein, in both labeled and non-labeled assay formats, with sensitivities of 30ngmL(-1) and 2pgmL(-1), respectively., This research was funded by FEDER and the MINECO projects CTQ/2016/75749-R and TEC/2017/84846-R. The authors acknowledge the contribution of the Bc's D students Alejandra Vargas and Ismael Guerrero for the time spent at our lab and for their enthusiastic ideas on the possibilities of MPC hydrogel.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and Characterization of ITO-Covered Resonant Nanopillars for Dual Optical and Electrochemical Sensing

  • Tramarin, Luca
  • Casquel, Rafael
  • Gil-Rostra, Jorge
  • Herrero-Labrador, Raquel
  • Murillo, Ana María M.
  • Laguna, María Fé
  • González-Elipe, Agustín R.
  • Holgado, Miguel
  • González Martínez, Miguel Ángel|||0000-0002-5104-1262
  • Bañuls Polo, María-José|||0000-0002-2422-7731
[EN] In this work we present a dual optical and electrochemical sensor based on SiO2/Si3N4 resonant nanopillars covered with an indium tin oxide (ITO) thin film. A 25-30 nm thick ITO layer deposited by magnetron sputtering acts as an electrode when incorporated onto the nanostructured array, without compromising the optical sensing capability of the nanopillars. Bulk sensing performances before and after ITO deposition have been measured and compared in accordance with theoretical calculations. The electrochemical activity has been determined by the ferri/ferrocyanide redox reaction, showing a remarkably higher activity than that of flat thin films of similar ITO nominal thickness, and proving that the nanopillar system covered by ITO presents electrical continuity. A label-free optical biological detection has been performed, where the presence of amyloid-beta has been detected through an immunoassay enhanced with gold nanoparticles. Again, the experimental results have been corroborated by theoretical simulations. We have demonstrated that ITO can be a beneficial component for resonant nanopillars sensors by adding potential electrochemical sensing capabilities, without significantly altering their optical properties. We foresee that resonant nanopillars coated with a continuous ITO film could be used for simultaneous optical and electrochemical biosensing, improving the robustness of biomolecular identification., This research was funded by the Spanish Ministry (Ministerio de Economia y Competitividad) under project HERON (Grant TEC2017-84846-R). Moreover, the work of L. Tramarin was supported by the predoctoral contract of the Universidad Politecnica de Madrid.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Alternative Brain Slice-on-a-Chip for Organotypic Culture and Effective Fluorescence Injection Testing

  • Herreros, P.
  • Tapia-González, Silvia
  • Sánchez-Olivares, L.
  • Heras, M.F.L.
  • Holgado, M.
Mouse brain slices are one of the most common models to study brain development and functioning, increasing the number of study models that integrate microfluidic systems for hippocampal slice cultures. This report presents an alternative brain slice-on-a-chip, integrating an injection system inside the chip to dispense a fluorescent dye for long-term monitoring. Hippocampal slices have been cultured inside these chips, observing fluorescence signals from living cells, maintaining the cytoarchitecture of the slices. Having fluorescence images of biological samples inside the chip demonstrates the effectiveness of the staining process using the injection method avoiding leaks or biological contamination. The technology developed in this study presents a significant improvement in the local administration of reagents within a brain slice-on-a-chip system, which could be a suitable option for organotypic cultures in a microfluidic chip acting as a highly effective bioreactor., The research was funded by the Ministerio de Economía y Competitividad of Spain (grant TEC2017-84846-R); Comunidad de Madrid, grant (P2018/BAA-4480); Spanish “Ministerio de Ciencia e Innovación” (grant PGC2018-094307-B-I00); and Cajal Blue Brain Project (the Spanish partner of the Blue Brain Project initiative from EPFL (Switzerland))
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

HEPA filters of portable air cleaners as a tool for the surveillance of SARS-CoV-2

  • Fernández de Mera, Isabel G.
  • Granda, Carmen
  • Villanueva, Florentina
  • Sánchez-Sánchez, Marta
  • Moraga‑Fernández, Alberto
  • Gortázar, Christian
  • Fuente, José de la
Studies about the identification of SARS-CoV-2 in indoor aerosols have been conducted in hospital patient rooms and to a lesser extent in nonhealthcare environments. In these studies, people were already infected with SARS-CoV-2. However, in the present study, we investigated the presence of SARS-CoV-2 in HEPA filters housed in portable air cleaners (PACs) located in places with apparently healthy people to prevent possible outbreaks. A method for detecting the presence of SARS-CoV-2 RNA in HEPA filters was developed and validated. The study was conducted for 13 weeks in three indoor environments: school, nursery, and a household of a social health center, all in Ciudad Real, Spain. The environmental monitoring of the presence of SARS-CoV-2 was conducted in HEPA filters and other surfaces of these indoor spaces for a selective screening in asymptomatic population groups. The objective was to limit outbreaks at an early stage. One HEPA filter tested positive in the social health center. After analysis by RT-PCR of SARS-CoV-2 in residents and healthcare workers, one worker tested positive. Therefore, this study provides direct evidence of virus-containing aerosols trapped in HEPA filters and the possibility of using these PACs for environmental monitoring of SARS-CoV-2 while they remove airborne aerosols and trap the virus., This work was supported by the Research and Innovation program of Universidad Politécnica de Madrid (https://www.upm.es/Investigacion/Programa_Propio_UPM) under the project with reference: VIMPACTO20MHB, the project HERON with reference TEC2017-84846-R supported by the Spanish Ministry of economy and competitiveness, and within the framework of the project COVIDTECH-CM of the regional government of Madrid (Spain)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Phosphorylated Tau at T181 accumulates in the serum of hibernating Syrian hamsters and rapidly disappears after arousal

  • León-Espinosa, G.
  • Murillo, A.M.M.
  • Turegano-Lopez, M.
  • DeFelipe, Javier
  • Holgado, M.
The search for biomarkers for the early diagnosis of neurodegenerative diseases is a growing area. Numerous investigations are exploring minimally invasive and cost-effective biomarkers, with the detection of phosphorylated Tau (pTau) protein emerging as one of the most promising fields. pTau is the main component of the paired helical filaments found in the brains of Alzheimer’s disease cases and serves as a precursor in the formation of neurofibrillary tangles (NFTs). Recent research has revealed that analysis of p-Tau181, p-Tau217 and p-Tau231 in blood may be an option for detecting the preclinical stage of Alzheimer’s disease. In this study, we have analyzed the values of pTau 181 in the serum of Syrian hamsters during hibernation. Naturally, over the course of hibernation, these animals exhibit a reversible accumulation of pTau in the brain tissue, which rapidly disappears upon awakening. A biosensing system based on the interferometric optical detection method was used to measure the concentration of pTau181 protein in serum samples from Syrian hamsters. This method eliminates the matrix effect and amplifies the signal obtained by using silicon dioxide nanoparticles (SiO NPs) biofunctionalized with the αpTau181 antibody. Our results indicate a substantial increase in the serum concentration of pTau in threonine-181 during hibernation, which disappears completely 2–3 h after awakening. Investigating the mechanism by which pTau protein appears in the blood non-pathologically may enhance current diagnostic techniques. Furthermore, since this process is reversible, and no tangles are detected in the brains of hibernating hamsters, additional analysis may contribute to the discovery of improved biomarkers. Additionally, exploring drugs targeting pTau to prevent the formation of tangles or studying the outcomes of any pTau-targeted treatment could be valuable., FUSP-PPC-19-264E8B2F/Universidad San Pablo - CEU PID2021-127924NB-I00/MCIN/AEI/10.13039/501100011033; CSIC Interdisciplinary Thematic Platform - Cajal Blue Brain (PTI-BLUEBRAIN; Spain) CB06/05/0066/CIBERNED, ISCIII SOL-00116599/Center for the Development of Industrial Technology (CDTI) IND2019/IND-17207/Spanish Ministry of Economy and Competitiveness project TEC2017-84846-R, Madrid Regional
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

The uncertainty and limit of detection in biosensors from immunoassays

  • Vicente Oliva, Jesús de|||0000-0001-5746-1543
  • Lavín Hueros, Álvaro|||0000-0001-9981-2372
  • Holgado Bolaños, Miguel|||0000-0001-9299-1371
  • Laguna Heras, Maria Fe|||0000-0002-1580-4509
  • Casquel del Campo, Rafael|||0000-0003-2433-9159
  • Santamaría Fernández, Beatriz|||0000-0003-3714-7922
  • Quintero Moreno, Sergio Andrés|||0000-0002-4545-7819
  • López Hernandez, Ana|||0000-0002-4415-1826
  • Ramírez, Yolanda|||0000-0003-0468-5871