Skip to main content

NUCLEAR STRUCTURE, APPLICATIONS AND ASTROPHYSICS: THE PATH TO FAIR

FPA2011-24553

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2011
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Proyectos de Investigación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons

  • Guadilla Gómez, Víctor
  • Algora, Alejandro
  • Taín, José Luis
  • Agramunt, Jorge
  • Gelletly, W.
  • Jordán Martín, M. Dolores
  • Monserrate, Manuel
  • Montaner-Pizá, A.
  • Nácher, Enrique
  • Orrigo, S. E. A.
  • Rubio, Berta
  • Valencia, Ebhelixes
  • Zakari-Issoufou, A.A.
V. Guadilla et al. -- 5 pags., 8 figs., tab., In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic β-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis., This work has been supported by the Spanish Ministerio de Economía y Competitividad under grants FPA2011-24553, AIC-A-2011-0696, FPA2014-52823-C2-1-P and the program Severo Ochoa (SEV-2014-0398), by the European Commission under the FP7/EURATOM contract 605203, and by the Spanish Ministerio de Educación under the FPU12/01527 grant., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization and performance of the DTAS detector

  • Guadilla Gómez, Víctor
  • Tain, José Luis
  • Algora, Alejandro
  • Agramunt, Jorge
  • Äystö, J.
  • Briz, José Antonio
  • Cucoanes, A.
  • Eronen, T.
  • Estienne, M.
  • Fallot, M.
  • Fraile, Luis M.
  • Ganioglu, Ela
  • Gelletly, W.
  • Gorelov, D.
  • Hakala, J.
  • Jokinen, A.
  • Jordan, D.
  • Kankainen, A.
  • Kolhinen, V.
  • Koponen, J.
  • Lebois, M.
  • Le Meur, L.
  • Martínez, T.
  • Monserrate, Manuel
  • Montaner-Pizá, A.
  • Moore, I.
  • Nácher, Enrique
  • Orrigo, S. E. A.
  • Penttilä, H.
  • Pohjalainen, I.
  • Porta, A.
  • Reinikainen, J.
  • Reponen, M.
  • Rice, S.
  • Rinta-Antila, S.
  • Rubio, Berta
  • Rytkönen, K.
  • Shiba, T.
  • Sonnenschein, V.
  • Sonzogni, A. A.
  • Valencia, Ebhelixes
  • Vedia, V.
  • Voss, A.
  • Wilson, J. N.
  • Zakari-Issoufou, A. A.
11 pags., 16 figs., 3 tabs., DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of β-delayed neutron emitting nuclei., This work has been supported by the Spanish Ministerio de Economia y Competitividad under grants FPA2011-24553, AIC-A-2011-0696, FPA2014-52823-C2-1-P and the program Severo Ochoa (SEV-2014-0398), by the European Commission under the FP7/EURATOM contract 605203, and by the Spanish Ministerio de Educacion Cultura y Deporte under the FPU12/01527 grant. The work was also supported by the UK Science and Technology Facilities Council (STFC) grant 14 ST/P005314/1. E. Ganioglu was supported by the Istanbul University Scientic Research Project Unit under FYO-2017-24144 project., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

First tests of the applicability of γ-ray imaging for background discrimination in time-of-flight neutron capture measurements

  • Pérez Magán, D. L.
  • Caballero Ontanaya, Luis
  • Domingo Pardo, César
  • Agramunt, Jorge
  • Albiol Colomer, Francisco
  • Casanovas, A.
  • González, A.
  • Guerrero, C.
  • Lerendegui-Marco, J.
  • Tarifeño-Saldivia, A.
  • The n_TOF Collaboration
In this work we explore for the first time the applicability of using γ-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr3 scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a 197Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample., This work was partially supported by Spanish Ministerio de Economía y Competitivdad under Grant nos. FPA2011-24553, FPA2013-45083-P and SEV-2014-0398. CDP acknowledges financial support from a grant of the Generalitat Valenciana GV2013 Grupos de Investigación Emergentes and a grant from Universidad de Valencia UV-INV-PRECOMP12-80717., No