Publication Artículo científico (JournalArticle)

Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons

  • Guadilla Gómez, Víctor
  • Algora, Alejandro
  • Taín, José Luis
  • Agramunt, Jorge
  • Gelletly, W.
  • Jordán Martín, M. Dolores
  • Monserrate, Manuel
  • Montaner-Pizá, A.
  • Nácher, Enrique
  • Orrigo, S. E. A.
  • Rubio, Berta
  • Valencia, Ebhelixes
  • Zakari-Issoufou, A.A.
V. Guadilla et al. -- 5 pags., 8 figs., tab., In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic β-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis., This work has been supported by the Spanish Ministerio de Economía y Competitividad under grants FPA2011-24553, AIC-A-2011-0696, FPA2014-52823-C2-1-P and the program Severo Ochoa (SEV-2014-0398), by the European Commission under the FP7/EURATOM contract 605203, and by the Spanish Ministerio de Educación under the FPU12/01527 grant., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization and performance of the DTAS detector

  • Guadilla Gómez, Víctor
  • Tain, José Luis
  • Algora, Alejandro
  • Agramunt, Jorge
  • Äystö, J.
  • Briz, José Antonio
  • Cucoanes, A.
  • Eronen, T.
  • Estienne, M.
  • Fallot, M.
  • Fraile, Luis M.
  • Ganioglu, Ela
  • Gelletly, W.
  • Gorelov, D.
  • Hakala, J.
  • Jokinen, A.
  • Jordan, D.
  • Kankainen, A.
  • Kolhinen, V.
  • Koponen, J.
  • Lebois, M.
  • Le Meur, L.
  • Martínez, T.
  • Monserrate, Manuel
  • Montaner-Pizá, A.
  • Moore, I.
  • Nácher, Enrique
  • Orrigo, S. E. A.
  • Penttilä, H.
  • Pohjalainen, I.
  • Porta, A.
  • Reinikainen, J.
  • Reponen, M.
  • Rice, S.
  • Rinta-Antila, S.
  • Rubio, Berta
  • Rytkönen, K.
  • Shiba, T.
  • Sonnenschein, V.
  • Sonzogni, A. A.
  • Valencia, Ebhelixes
  • Vedia, V.
  • Voss, A.
  • Wilson, J. N.
  • Zakari-Issoufou, A. A.
11 pags., 16 figs., 3 tabs., DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of β-delayed neutron emitting nuclei., This work has been supported by the Spanish Ministerio de Economia y Competitividad under grants FPA2011-24553, AIC-A-2011-0696, FPA2014-52823-C2-1-P and the program Severo Ochoa (SEV-2014-0398), by the European Commission under the FP7/EURATOM contract 605203, and by the Spanish Ministerio de Educacion Cultura y Deporte under the FPU12/01527 grant. The work was also supported by the UK Science and Technology Facilities Council (STFC) grant 14 ST/P005314/1. E. Ganioglu was supported by the Istanbul University Scientic Research Project Unit under FYO-2017-24144 project., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Commissioning of the BRIKEN detector for the measurement of very exotic β-delayed neutron emitters

  • BRIKEN Collaboration
  • Tolosa-Delgado, A.
  • Agramunt, Jorge
  • Taín, José Luis
  • Algora, Alejandro
  • Domingo Pardo, César
  • Morales, Ana Isabel
  • Rubio, Berta
  • Tarifeño-Saldivia, A.
  • Calviño, F.
  • Cortés, Guillem
  • Brewer, N. T.
  • Rasco, B. C.
  • Rykaczewski, K. P.
  • Rykaczewski, K. P.
  • Stracener, D. W.
  • Allmond, J. M.
  • Grzywacz, R.
  • Yokoyama, R.
  • Singh, M.
  • King, T.
  • Madurga, Miguel
  • Nishimura, S.
  • Phong, V.H.
  • Go, S.
  • Liu, J.
  • Matsui, K.
  • Sakurai, H.
  • Kiss, G.G.
  • Isobe, T.
  • Baba, H.
  • Kubono, S.
  • Fukuda, N.
  • Ahn, D.S.
  • Shimizu, Y.
  • Sumikama, T.
  • Suzuki, H.
  • Takeda, H.
  • Söderström, P. A.
  • Takechi, M.
  • Bruno, C. G.
  • Davinson, T.
  • Griffin, C.J.
  • Hall, O.
  • Kahl, D.
  • Woods, P. J.
  • Woods, P. J.
  • Coleman-Smith, P. J.
  • Labiche, M.
  • Lazarus, I.
  • Morrall, P.
  • Pucknell, V.F.E.
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and γ-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and β-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Cross section measurements of 155,157Gd(n, γ) induced by thermal and epithermal neutrons

  • n_TOF Collaboration
  • Mastromarco, M.
  • Manna, A.
  • Aberle, O.
  • Andrzejewski, Józef
  • Audouin, L.
  • Bacak, M.
  • Balibrea, Javier
  • Barbagallo, M.
  • Be¿vá¿, F.
  • Berthoumieux, Eric
  • Billowes, J.
  • Bosnar, D.
  • Brown, A.
  • Caamaño, M.
  • Calviño, F.
  • Calviani, M.
  • Cano-Ott, D.
  • Cardella, R.
  • Casanovas, A.
  • Castelluccio, D.M.
  • Cerutti, F.
  • Chen, Y.H.
  • Chiaveri, E.
  • Clai, G.
  • Colonna, N.
  • Cortés, Guillem
  • Cortés-Giraldo, Miguel Antonio
  • Cosentino, L.
  • Damone, L.A.
  • Diakaki, Maria
  • Domingo Pardo, César
  • Dressler, R.
  • Dupont, E.
  • Durán, Ignacio
  • Fernández-Domínguez, B.
  • Ferrari, A.
  • Ferreira, P.
  • Finocchiaro, P.
  • Furman, V.
  • Göbel, K.
  • García, A.R.
  • Gawlik, A.
  • Gilardoni, Simone
  • Glodariu, T.
  • Gonçalves, I.F.
  • González-Romero, E.
  • Griesmayer, E.
  • Guerrero, C.
  • Gunsing, F.
  • Guglielmelli, A.
  • Leal-Cidoncha, E.
  • Martínez, T.
  • Mendoza, E.
  • Mengoni, A.
  • Porras, I.
  • Praena, J.
  • Rocchi, F.
  • Tarifeño-Saldivia, A.
  • Taín, José Luis
Neutron capture cross section measurements on Gd and Gd were performed using the time-of-flight technique at the n_TOF facility at CERN on isotopically enriched samples. The measurements were carried out in the n_TOF experimental area EAR1, at 185 m from the neutron source, with an array of 4 CD liquid scintillation detectors. At a neutron kinetic energy of 0.0253 eV, capture cross sections of 62.2(2.2) and 239.8(8.4) kilobarn have been derived for Gd and Gd, respectively, with up to 6% deviation relative to values presently reported in nuclear data libraries, but consistent with those values within 1.6 standard deviations. A resonance shape analysis has been performed in the resolved resonance region up to 181 eV and 307 eV, respectively for Gd and Gd, where on average, resonance parameters have been found in good agreement with evaluations. Above these energies and up to 1 keV, the observed resonance-like structure of the cross section has been analysed and characterised. From a statistical analysis of the observed neutron resonances we deduced: neutron strength function of 2. 01 (28) × 10 and 2. 17 (41) × 10 ; average total radiative width of 106.8(14) meV and 101.1(20) meV and s-wave resonance spacing 1.6(2) eV and 4.8(5) eV for n + Gd and n + Gd systems, respectively.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

gamma-Ray position reconstruction in large monolithic LaCl3(Ce) crystals with SiPM readout

  • Babiano-Suárez, V.
  • Caballero Ontanaya, Luis
  • Calvo, D.
  • Ladarescu, I.
  • Olleros, P.
  • Domingo Pardo, César
We report on the spatial response characterization of large LaCl3(Ce) monolithic crystals optically coupled to 8 x 8 pixel silicon photomultiplier (SiPM) sensors. A systematic study has been carried out for 511 keV gamma-rays using three different crystal thicknesses of 10 mm, 20 mm and 30 mm, all of them with planar geometry and a base size of 50 x 50 mm(2). In this work we investigate and compare two different approaches for the determination of the main gamma-ray hit location. On one hand, methods based on the fit of an analytical model for the scintillation light distribution provide the best results in terms of linearity and field of view, with spatial resolutions close to similar to 1 mm FWHM. On the other hand, position reconstruction techniques based on neural networks provide similar linearity and field-of-view, becoming the attainable spatial resolution similar to 3 mm FWHM. For the third space coordinate z or depth-of-interaction we have implemented an inverse linear calibration approach based on the cross-section of the measured scintillation-light distribution at a certain height. The detectors characterized in this work are intended for the development of so-called Total Energy Detectors with Compton imaging capability (i-TED), aimed at enhanced sensitivity and selectivity measurements of neutron capture cross sections via the time-of-flight (TOF) technique.