Skip to main content

DESARROLLO DE INSTRUMENTACION OPTICA AVANZADA PARA APLICACIONES EN POLARIMETRIA DE IMAGEN Y METROLOGIA DE SUPERFICIES POR DEFLECTOMETRIA DE FRANJAS

FIS2015-66328-C3-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre UNIVERSIDAD AUTONOMA DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Misalignment error analysis in polychromatic division of focal plane Stokes polarimeters

  • Lizana Tutusaus, Ángel
  • Campos Coloma, Juan
  • Van Eeckhout, Albert
  • Márquez, Andrés
  • Márquez, Andrés|||/items/124ea25f-0096-4a92-b0d3-28227c2beec0
Snapshot imaging polarimeters are used in many different areas. Recently, division of focal plane (DoFP) polarimeters have proved useful as snapshot polarimeters for dynamic applications. For an optimal performance of polarimeters, different works dealing with the error analysis of such devices are proposed in literature. In terms of noise amplification from intensity measurements to the final polarization calculations, well-established quality metrics, as in the condition number or the equally weighted variance criteria, are used. Other studies analyze systematic errors due to deviations in the construction parameters. However, something not considered so far is the effect produced by misalignment between the various pixelated masks over the pixelated structure of the camera sensor, always occurring in experimental implementations of DoFPs. In this work, we study the effect of such misalignments in DoFP polarimeters and demonstrate how they lead to polarimetric systems composed of partially depolarized analyzers. We calculate the combined degree of polarization related to different amounts of misalignment and analyze the corresponding system performance. From this study, we show how an imaging polarimeter based on partially polarized analyzers can still lead to a robust and accurate polarimetric performance, and we also provide the misalignment limits in which an acceptable performance is obtained. We evaluate both the monochromatic and the polychromatic cases with special focus on the latter.