Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)
DUGiMedia – Universitat de Girona
oai:diobma.udg.edu:10256.1/1107
. 1990

SAMBA KUBALLY. UNA EXPERIÈNCIA D'ALFABETITZACIÓ D'IMMIGRANTS A CATALUNYA

  • Kamara, Amador
  • Krubally, Ibrahim
  • Janngana, Bully
  • Colomer i Ribas, Joan
  • Tort, Josep
  • Parra Noño, Sebastià
  • Ruiz, Antoni
Reportatge sobre la creació de l'Escola africana d'adults Samba Kubally, especialitzada en l'alfabetització d'immigrants africans, 1107.mp4 1107.mp3

Proyecto: //
DOI: http://hdl.handle.net/10256.1/1107
DUGiMedia – Universitat de Girona
oai:diobma.udg.edu:10256.1/1107
HANDLE: http://hdl.handle.net/10256.1/1107
DUGiMedia – Universitat de Girona
oai:diobma.udg.edu:10256.1/1107
PMID: http://hdl.handle.net/10256.1/1107
DUGiMedia – Universitat de Girona
oai:diobma.udg.edu:10256.1/1107
Ver en: http://hdl.handle.net/10256.1/1107
DUGiMedia – Universitat de Girona
oai:diobma.udg.edu:10256.1/1107

Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/125243
Dataset. 2015

CARBON DATA OBTAINED DURING THE R/V SARMIENTO DE GAMBOA CAIBOX-2009 CRUISE IN THE ATLANTIC OCEAN (25 JULY - 13 AUGUST, 2009)

  • Gilcoto, Miguel
  • Pérez, Fiz F.
  • Ríos, Aida F.
  • Pardo, Paula C.
  • Carracedo, L.
  • Vieitez dos Santos, Vanesa
  • Paz, M. de la
The item is made of 2 files, of which 1 is the dataset and the other include a small description of the measured variables.-- Dataset contributed to the Project Carbochange, This dataset gathers discrete measurements of CO2 (pH and alkalinity) and hydrographic variables (salinity, temperature, dissolved oxygen, nitrate, phosphate and silicate) obtained during the cruise CAIBOX 2009 carried out from 25 July to 13 August 2009. pH was measured spectrophotometrically following the Clayton and Byrne (1993). This method consists on adding a dye solution to the seawater sample, so that the ratio between two absorbances at two different wavelengths is proportional to the sample pH. Alkalinity was measured using an automatic potentiometric titrator Titrando 809 Metrohm, with a Metrohm 6.0232.100 combination glass electrode and a Pt-1000 probe for temperature measurement following the methodology given by Pérez and Fraga (1987). Dissolved oxygen was analyzed following the widely applied Winkler method. Determinations of nitrate, phosphate and silicate were carried out following methods described by Hansen and Grassoff (1983) Salinity and Temperature were recorded with a CTD probe, Spanish Project CAIBEX supported by Ministerio de Eduación y Ciencia (CTM2007–66408–C02–01/MAR), CARBOOCEAN (511176GOCE), No

Proyecto: EC/FP7/264879
DOI: http://hdl.handle.net/10261/125243
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/125243
HANDLE: http://hdl.handle.net/10261/125243
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/125243
PMID: http://hdl.handle.net/10261/125243
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/125243
Ver en: http://hdl.handle.net/10261/125243
Digital.CSIC. Repositorio Institucional del CSIC
oai:digital.csic.es:10261/125243

Advanced search