Skip to main content

DISEÑO DE UN BIOSENSOR DE ADN BASADO EN TECNOLOGIA HFF-QCM PARA LA DETECCION DE SUSTANCIAS ADULTERANTES EN MIEL

AGL2016-77702-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Monitoring honey adulteration with sugar syrups using an automatic pulse voltammetric electronic tongue

  • Sobrino-Gregorio, Lara
  • Bataller Prats, Román
  • Soto Camino, Juan
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
[EN] The new tendency to detect adulterated honey is the development of affordable analytical equipment that is in-line and manageable, enabling rapid on site screening. Therefore, the aim of this work was to apply an electronic tongue based on potential multistep pulse voltammetry, in combination with multivariate statistical techniques to detect and quantify syrup in honey. Pure monofloral honey (heather, orange blossom and sunflower), syrup (rice, barley and corn), and samples simulating adulterated honey with different percentages of syrup (2.5, 5, 10, 20 and 40) were evaluated. An automatic, electrochemical system for cleaning and polishing the electronic tongue sensors (Ir, Rh, Pt, Au) significantly improved the repeatability and accuracy of the measurements. PCA analysis showed that the proposed methodology is able to distinguish between types of pure honey and syrup, and their different levels of adulterants. A subsequent PLS analysis successfully predicted the level of the adulterants in each honey, achieving good correlations considering the adjusting parameters. The best results being for sunflower honey adulterated with corn syrup and heather honey with barley syrup (r2 ¿ 0.997), and heather with corn (r2 ¿ 0.994) whereas the weakest was found for heather honey adulterated with brown rice syrup (r2 ¿ 0.763) and orange blossom honey with corn syrup (r2 ¿ 0.879). The measurement system here proposed could be a very quick and effective option for the honey packaging sector with the finality of providing information about a characteristic as important as the adulteration of honey., This study forms part of the projects funded by the "Agencia Estatal de Investigacion" (AGL2016-77702-R) and by the "Generalitat Valenciana" (AICO/2015/104) of Spain, for which the authors are grateful.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A fast method for monitoring the shifts in resonance frequency and dissipation of the QCM sensors of a Monolithic array in biosensing applications

  • FERNÁNDEZ DÍAZ, ROMÁN|||0000-0002-8883-4653
  • García Narbón, José Vicente|||0000-0001-6303-8258
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
  • Calero-Alcarria, María Del Señor
  • Reiviakine, Ilya
[EN] Improvement of data acquisition rate remains as an important challenge in applications with Quartz Crystal Microbalance (QCM) technology where high throughput is required. To address this challenge, we developed a fast method capable of measuring the response of a large number of sensors and/or overtones, with a high time resolution. Our method, which can be implemented in a low-cost readout electronic circuit, is based on the estimation of fr (frequency shift) and D (dissipation shift) from measurements of the sensor response obtained at a single driving frequency. By replacing slow fitting procedures with a direct calculation, the time resolution is only limited by the physical characteristics of the sensor (resonance frequency and quality factor), but not by the method itself. Capabilities of the method are demonstrated by monitoring multiple overtones with a single 5 MHz sensor and a Monolithic QCM array comprising 24 50MHz-sensors. Accuracy of the method is validated and compared with the state-of-the-art, as well as with a reference method based on impedance analysis., This work was supported in part by the Ministerio de Economía, Industria y Competitividad de España-Agencia Estatal de Investigación with Fondo Europeo de Desarrollo Regional (FEDER) Funds under Grant AGL2016-77702-R and in part by the European Commission Horizon 2020 Programme (Capturing non-amplified tumor circulating DNA with ultrasound hydrodynamics) under Agreement H2020-FETOPEN-2016-2017/737212-CATCH-UDNA. The work of María Calero was supported by the Spanish Ministry of Economy, Industry and Competitiveness, Madrid, Spain, under Grant BES-2017-080246.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High Fundamental Frequency (HFF) Monolithic Quartz Crystal Microbalance with Dissipation Array for the Simultaneous Detection of Pesticides and Antibiotics in Complex Food

  • Calero-Alcarria, María Del Señor
  • García, María
  • Montoya, Ángel
  • FERNÁNDEZ DÍAZ, ROMÁN|||0000-0002-8883-4653
  • Juan-Borras, María del Sol|||0000-0003-4774-9484
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
[EN] As in the case of the food industry in general, there is a global concern about safety and quality in complex food matrices, such as honey, which is driving the demand for fast, sensitive and affordable analytical techniques across the honey-packaging industry. Although excellent techniques such as liquid chromatography-tandem mass spectrometry (LC-MS/MS) are available, these are located in centralized laboratories and are still lacking in speed, simplicity and cost-effectiveness. Here, a new approach is presented where a competitive immunoassay is combined with a novel High Fundamental Frequency Quartz Crystal Microbalance with Dissipation (HFF-QCMD) array biosensor for the simultaneous detection of antibiotics and pesticides in honey. Concretely, thiabendazole and sulfathiazole residues were monitored in spiked honey samples. Results revealed that HFF-QCMD arrays provide a complementary and reliable tool to LC-MS/MS for the analysis of contaminants in these kinds of complex matrices, while avoiding elaborate sample pre-treatment. The good sensitivity achieved (I50 values in the 70¿720 µg/kg range) and the short analysis time (60 min for 24 individual assays), together with the ability for multiple analyte detection (24 sensor array) and its cost-effectiveness, pave the way for the implementation of a fast on-line, in situ routine control of potentially hazardous chemical residues in honey., This work was supported by Ministerio de Economía, Industria y Competitividad de España-Agencia Estatal de Investigación with FEDER (Fondo Europeo de Desarrollo Regional) funds under Grants AGL2016-77702-R and AGL2013-48646-R. M. Calero is the recipient of the doctoral fellowship BES-2017-080246 from the Ministerio de Economía, Industria y Competitividad de España.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Multichannel Microfluidic Sensing Cartridge for Bioanalytical Applications of Monolithic Quartz Crystal Microbalance

  • Calero-Alcarria, María Del Señor
  • GARCIA MOLLA, PABLO
  • García, María
  • Gamero-Sandemetrio, Esther
  • Reviakine, Ilya
  • FERNÁNDEZ DÍAZ, ROMÁN|||0000-0002-8883-4653
  • García Narbón, José Vicente|||0000-0001-6303-8258
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
[EN] Integrating acoustic wave sensors into lab-on-a-chip (LoC) devices is a well-known challenge. We address this challenge by designing a microfluidic device housing a monolithic array of 24 high-fundamental frequency quartz crystal microbalance with dissipation (HFF-QCMD) sensors. The device features six 6-µL channels of four sensors each for low-volume parallel measurements, a sealing mechanism that provides appropriate pressure control while assuring liquid confinement and maintaining good stability, and provides a mechanical, electrical, and thermal interface with the characterization electronics. We validate the device by measuring the response of the HFF-QCMD sensors to the air-to-liquid transition, for which the robust Kanazawa¿Gordon¿Mason theory exists, and then by studying the adsorption of model bioanalytes (neutravidin and biotinylated albumin). With these experiments, we show how the effects of the protein¿surface interactions propagate within adsorbed protein multilayers, offering essentially new insight into the design of affinity-based bioanalytical sensors, This work was supported in part by Ministerio de Economía, Industria y Competitividad de España Agencia Estatal de Investigación with FEDER (Fondo Europeo de Desarrollo Regional) funds under Project AGL2016-77702-R and in part by the European Commission Horizon 2020 Programme, Capturing non-Amplified Tumor Circulating DA with Ultrasound Hidrodynamics, under Grant H2020-FETOPEN-2016-2017/737212-CATCH-U-DNA. M. Calero is the recipient of the doctoral fellowship BES-2017-080246 from the Ministerio de Economía, Industria y Competitividad de España.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

High Fundamental Frequency (HFF) Monolithic Resonator Arrays for Biosensing Applications: Design, Simulations, Experimental, Characterization

  • FERNÁNDEZ DÍAZ, ROMÁN|||0000-0002-8883-4653
  • García Narbón, José Vicente|||0000-0001-6303-8258
  • ROCHA GASO, MARÍA ISABEL|||0000-0003-2949-4457
  • Arnau Vives, Antonio|||0000-0002-5709-1690
  • Jiménez Jiménez, Yolanda|||0000-0003-4835-9007
  • Calero-Alcarria, María Del Señor
  • Reviakine, Ilya
[EN] Miniaturized, high-throughput, cost-effective sensing devices are needed to advance lab-on-a-chip technologies for healthcare, security, environmental monitoring, food safety, and research applications. Quartz crystal microbalance with dissipation (QCMD) is a promising technology for the design of such sensing devices, but its applications have been limited, until now, by low throughput and significant costs. In this work, we present the design and characterization of 24-element monolithic QCMD arrays for high-throughput and low-volume sensing applications in liquid. Physical properties such as geometry and roughness, and electrical properties such as resonance frequency, quality factor, spurious mode suppression, and interactions between array elements (crosstalk), are investigated in detail. In particular, we show that the scattering parameter, S 21 , commonly measured experimentally to investigate crosstalk, contains contributions from the parasitic grounding effects associated with the acquisition circuitry. Finite element method simulations do not take grounding effects into account explicitly. However, these effects can be effectively modelled with appropriate equivalent circuit models, providing clear physical interpretation of the different contributions. We show that our array design avoids unwanted interactions between elements and discuss in detail aspects of measuring these interactions that are often-overlooked., The authors would also like to thank Jorge Martínez from the Laboratory of High Frequency Circuits (LCAF) of the Universitat Politècnica de València (UPV) for assistance with profilometry, and Manuel Planes, José Luis Moya, Mercedes Tabernero, Alicia Nuez, and Joaquin Fayos from the Electron Microscopy Services of the UPV for helping with the AFM, and SEM measurements. M. Calero is the recipient of the doctoral fellowship BES-2017-080246 from the Spanish Ministry of Economy, Industry and Competitiveness, Madrid, Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Detection of honey adulteration by conventional and real-time PCR

  • Sobrino-Gregorio, Lara
  • Vilanova Navarro, Santiago|||0000-0003-4939-9713
  • Prohens Tomás, Jaime|||0000-0003-1181-9065
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
[EN] This work applies both conventional and real-time PCR DNA amplification techniques for detecting and quantifying rice molasses in honey. Different levels of adulteration were simulated (1, 2, 5, 10, 20, 50%) using commercial rice molasses. Among the different specific genes of rice tested by PCR, the PLD1 primer was the most effective. This allowed the visualization in agarose gel of this type of adulterant up to 5-20%. Moreover, by means of real-time PCR it was possible to distinguish the different levels of rice DNA, and therefore the percentage of adulteration (1-50%). A standard curve built with the DNA serial dilutions of rice genomic DNA concentrations showed that the quantification level was between 2-5%. These results offer compelling evidence that DNA techniques could be useful not only for the detection of adulterations of honey with rice molasses but also for the quantification of levels lower than those of conventional techniques., This study is part of part of the projects funded by the "Agencia Estatal de Investigacion" (AGL2016-77702-R) and by the "Generalitat Valenciana" (AICO/2015/104) of Spain, for which the authors are grateful.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Using an automatic pulse voltammetric electronic tongue to verify the origin of honey from Spain, Honduras, and Mozambique

  • Sobrino-Gregorio, Lara
  • Tanleque-Alberto, Fernando
  • Bataller Prats, Román
  • Soto Camino, Juan
  • Escriche Roberto, Mª Isabel|||0000-0003-0180-0360
[EN] BACKGROUND: The growing need to classify the origin of honey in a simple way is leading to the development of affordable analytical equipment that is in-line and manageable, enabling rapid on-site screening. The aim of this work was therefore to evaluate whether an electronic tongue (made of four metallic electrodes: Ir, Rh, Pt, Au), based on potential multistep pulse voltammetry with electrochemical polishing, is able to differentiate between honey samples from Spain, Honduras, and Mozambique. RESULTS: It was demonstrated, for the first time, that automatic pulse voltammetry, in combination with principal component analysis (PCA) statistical analysis, was able to differentiate honey samples from these three countries. A partial least squares (PLS) analysis predicted the level of certain physicochemical parameters, the best results being for conductivity and moisture with correlation coefficients of 0.948 and 0.879, whereas the weakest correlation was for the sugars. CONCLUSION: The tool proposed in this study could be applied to identify the country origin of the three types of multifloral honey considered here. It also offers promising perspectives for expanding knowledge of the provenance of honey. All of this could be achieved when a comprehensive database with the information generated by this electronic tongue has been created. © 2019 Society of Chemical Industry, This study forms part of the projects funded by the Ministerio de Economía y Competitividad, the Agencia Estatal de Investigación, and the Fondo Europeo de Desarrollo Regional (AGL2016-77702-R) and by the Programa ADSIDEO-cooperación 2016 of the Centro de Cooperación al Desarrollo de la Universitat Politècnica de València, Spain, for which the authors are grateful.