Ability of Swept-Source Optical Coherence Tomography to Detect Retinal and Choroidal Changes in Patients with Multiple Sclerosis

  • Garcia-Martin, E.
  • Jarauta, L.
  • Vilades, E.
  • Ara, J.R.
  • Martin, J.
  • Polo, V.
  • Larrosa, J.M.
  • Pablo, L.E.
  • Satue, M.
Purpose. To evaluate the ability of new swept-source (SS) optical coherence tomography (OCT) technology to detect changes in retinal and choroidal thickness in patients with multiple sclerosis (MS). Methods. A total of 101 healthy and 97 MS eyes underwent retinal and choroidal assessment using SS Triton OCT (Topcon). Macular thickness and peripapillary data (retinal, ganglion cell layer (GCL+, GCL++) and retinal nerve fiber layer (RNFL) thickness) were analyzed, including choroidal thickness evaluation. Results. Significant macular thinning was observed in all ETDRS areas (p<0.001) in MS patients. Peripapillary retinal, RNFL, and GCL ++ thickness showed a significant reduction in patients in all sectors (p<0.001) except in the nasal quadrant/sector (p>0.05). GCL+ measurements were found to be reduced in the nasal (p=0.003), inferonasal (p=0.045), and temporal (p=0.001) sectors and total thickness (p<0.001). Choroidal thickness was reduced in the outer macular ring in MS patients compared with controls (p=0.038). Conclusion. New swept-source technology for OCT devices detects retinal thinning in MS patients, providing increased depth analysis of the choroid in these patients. MS patients present reduced retinal and choroidal thickness in the macular area and reduced peripapillary retinal, RNFL, and GCL thickness.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Functional Evaluation of the Visual Pathway in Patients with Multiple Sclerosis Using a Multifunction Stimulator Monitor

  • Satue, M.
  • Jarauta, L.
  • Obis, J.
  • Cipres, M.
  • Rodrigo, M.J.
  • Almarcegui, C.
  • Dolz, I.
  • Ara, J.R.
  • Martin, J.
  • Pablo, L.E.
  • Garcia-Martin, E.
Objectives. To assess the capability of the vision monitor unit Monpack One of detecting visual function alterations in patients with multiple sclerosis (MS) and to evaluate the correlation between structural retinal parameters and functional measurements obtained with this device. Methods. Forty-eight patients with MS and 46 healthy controls were included in a cross-sectional study. All participants underwent a complete functional evaluation of the visual pathway, which included low-contrast visual acuity (LCVA), contrast sensitivity vision (CSV), automated perimetry, multifocal visual evoked potentials (mfVEPs), and pattern electroretinogram (ERG). All tests were performed using the vision monitor unit Monpack One (Metrovision, France), a multifunction stimulator device. Retinal structural measurements were obtained in all subjects using Triton swept source optical coherence tomography (Topcon, Japan). Results. Patients with MS presented reduced low-contrast VA (p<0.001) and reduced CSV at medium (p=0.001, p=0.013) and low (p=0.001, p=0.002) spatial frequencies. All visual field parameters were found to be altered in MS patients compared with controls (<= 0.001). Patients with MS presented lower amplitude of the P100 waveform of the mfVEP in areas corresponding to central (p<0.001), inferonasal (p=0.001), and inferotemporal (p=0.003) retina. The pattern ERG did not show significant differences. Significant correlations were observed between structural retinal measurements and functional parameters, especially between the inner macular areas and measurements corresponding to contrast sensitivity and perimetry indexes. Conclusions. Patients with MS present visual dysfunction detectable with the vision monitor unit Monpack One. This device may be a fast and useful tool to provide a full evaluation of axonal damage in patients with multiple sclerosis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Evaluation of progressive visual dysfunction and retinal degeneration in patients with parkinson’s disease

  • Satue, M.
  • Rodrigo, M.J.
  • Obis, J.
  • Vilades, E.
  • Gracia, H.
  • Otin, S.
  • Fuertes, M.I.
  • Alarcia, R.
  • Crespo, J.A.
  • Polo, V.
  • Larrosa, J.M.
  • Pablo, L.E.
  • Garcia-Martin, E.
PURPOSE. To quantify changes in visual function parameters and in the retinal nerve fiber layer and macular thickness over a 5-year period in patients with Parkinson’s disease (PD). METHODS. Thirty patients with PD and 30 healthy subjects underwent a complete ophthalmic evaluation, including assessment of visual acuity, contrast sensitivity vision, color vision, and retinal evaluation with spectral-domain optical coherence tomography (SD-OCT). All subjects were reevaluated after 5 years to quantify changes in visual function parameters, the retinal nerve fiber layer, and macular thickness. Association between progressive ophthalmologic changes and disease progression was analyzed. RESULTS. Changes were detected in visual function parameters and retinal nerve fiber layer thickness in patients compared with controls. Greater changes were found during the follow-up in the PD group than healthy subjects in visual acuity, contrast sensitivity, Lanthony color test (P < 0.016), in superotemporal and temporal retinal nerve fiber layer sectors (P < 0.001), and in macular thickness (all sectors except inner superior and inner inferior sectors, P < 0.001). Progressive changes in the retinal nerve fiber layer were associated with disease progression (r = 0.389, P = 0.028). CONCLUSIONS. Progressive visual dysfunction, macular thinning, and axonal loss can be detected in PD. Analysis of the macular thickness and the retinal nerve fiber layer by SD-OCT can be useful for evaluating Parkinson’s disease progression.