Skip to main content

MICROEXTRACION EN FASE SOLIDA EN TUBO ACOPLADA EN LINEA A NANOCROMATOGRAFIA LIQUIDA: NUEVAS OPORTUNIDADES PARA /DESDE LA NANOESCALA Y LA CROMATOGRAFIA LIQUIDA

CTQ2017-90082-P

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

New silica based adsorbent material from rice straw and its in-flow application to nitrate reduction in waters: Process sustainability and scale-up possibilities

  • Robles-Jimarez, H.R.
  • Sanjuan-Navarro, L.
  • Jornet-Martínez, N.
  • Primaz, C.T.
  • Molins-Legua, C.
  • Campins-Falcó, P.
  • Teruel-Juanes, Roberto|||0000-0002-0190-4445
  • Ribes-Greus, A.|||0000-0003-2460-8291
[EN] This paper shows a particular example to move to a sustainable circular economical process from valorization of rice straw ashes by developing a green synthesis for obtaining a useful sub-product. This strategy can palliate negative effects of the agriculture waste practices on the environment and also the obtained silica reduced nitrate content in waters. It is demonstrated that the silica synthesis developed at lab was scalable more than a hundred times with good results. Adsorption studies of nitrate in standards and real well waters at lab scale and scaling-up provided similar results. Adsorption values near to 15 mg/g for nitrate standards and 8.5 mg/g for well water were obtained until achieving the initial nitrate concentration. Experimental breakthrough curves fitted to Thomas model, which gave similar results for adsorption capacities. The adsorption capacity was checked with that obtained by a commercial resin, providing improved results. The method at large scale was compared with industrial traditional methods and green adsorbents., The authors are grateful to EU (EASME LIFE and CIP ECO-Innovation) LIBERNITRATE. LIFE 16 ENV/ES/000419; EU FEDER and the Gobierno de Espana MCIU-AEI (CTQ2017-90082-P) and the Generalitat Valenciana (PROMETEO 2020/078) and EU FEDER-Generalitat Valenciana (ID-FEDER/2018/049) for the financial support received. H. R. Robles-Jimarez expresses his grateful to EU-LIBERNITRATE. L. Sanjuan-Navarro expresses his gratitude for the FPU-grant (MCIU-AEI) .
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Fast Blue B Functionalized Silica-Polymer Composite to Evaluate 3,5-Dihydroxyhydrocinnamic Acid as Biomarker of Gluten Intake

  • Hakobyan, Lusine
  • Prieto-Blanco, M. C.
  • Roca, María
  • Molíns-Legua, Carmen
  • Fuster-García, M.
  • Moliner-Martínez, Yolanda
  • Campíns-Falcó, Pilar
  • Ribes-Koninckx, Carmen
This is an accepted version of the published document., [Abstract] Celiac disease is an immune-mediated systemic disorder elicited by gluten and related prolamines in genetically susceptible individuals. The current treatment is a strict and lifelong gluten-free diet. However, compliance with the gluten-free diet is not always adequate and many food products contain low concentrations of gluten. The determination of dietary transgressions is a challenge for patients, physicians and dietitians. Alkylresorcinols (AR) have been proposed as sensitive and specific biomarkers of gluten consumption. In this work silica–polymer composites doped with fast blue B reagent (FB) have been used to estimate alkylresorcinols in biological samples. The proposed colorimetric device was synthetized by immobilizing FB into polydimethylsiloxane-tetraethylortosilicate composite. The assay was based on the spontaneous release of FB to the solution containing AR (3,5-dihydroxyhydrocinnamic acid, DHCA) and the azocomplexe formation (520 nm). The response was evaluated with UV-vis spectroscopy and chromatography (in-tube SPME-Capillary LC-DAD) to isolate DHCA signal. The spectroscopic analysis can be used as a screening tool to differentiate positive and negative samples. Meanwhile, the chromatographic assay was necessary to isolate DHCA response in positive samples. LOD was 60 ng mL -1 by adding a SPE step. Precision provided adequate results (RSD < 15%). Preliminary studies in urine samples displayed successful results, showing DHCA can be used as biomarker of gluten intake. The here proposed methodology clearly simplifies the dietary transgression evaluation thanks to the development of a pre-screening tool before the chromatographic analysis., The authors are grateful to EU FEDER and the Spanish Government MCIU-AEI (CTQ2017-90082-P), the Generalitat Valenciana (PROMETEO 2020/078) and VLC-BIOMED program (PI2020-7) for the financial support received. L.H. to the University of Valencia for her predoctoral grant, Generalitat Valenciana; PROMETEO 2020/078, Universitat de València; PI2020-7
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Quantifying Both Ammonium and Proline in Wines and Beer by Using a PDMS Composite for Sensoring

  • Prieto-Blanco, M. C.
  • Jornet-Martínez, Neus
  • Verdú-Andrés, Jorge
  • Molíns-Legua, Carmen
  • Campíns-Falcó, Pilar
This is an accepted version of the published document., [Abstract] Two of the reagents involved in the Berthelot's reaction, thymol and nitroprusside, were embedded in a PDMS composite in order to apply this assay to determine ammonium and proline, in wine and beers. Safety, portability, rapidity, cost-effectiveness and simplicity of the assay were improved. For the proline determination, a modified Berthelot's reaction, which included a ring cleavage of proline, was optimized. The accuracy of the assay was tested. The limits of detection for ammonium was 0.12 µg mL−1 and for proline was in the range from 0.7 to 4.1 µg mL−1, depending on the kind of wine (white, red, or sweet), for beer the LOD was 6 µg mL−1. The precision achieved was slower than 10%. The accuracy of the assay was tested by means of a confirmatory validation study. Good results were obtained for real samples., The authors are grateful to the Spanish Ministerio de Economia y Competitividad (EU-FEDER/MINECO-AEI-Gobierno de España (CTQ2017-90082-P), Generalitat Valenciana (PROMETEO program 2012/045 and 2016/109), and the Program of Consolidation and Structuring of Units of Competitive Investigation of the University System of Galicia potentially co-financed by ERDF in the frame of the operative Program of Galicia (Xunta de Galicia, reference: ED431C 2017/28). MCP expresses their gratitude to the PROMETEO program for a grant and a research stay, Generalitat Valenciana; 2012/045, Generalitat Valenciana; 2016/109, Xunta de Galicia; ED431C 2017/28
RUC. Repositorio da Universidade da Coruña
Publication Artículo científico (JournalArticle)

Footprint of Carbonyl Compounds in Hand Scent by In-Tube Solid-Phase Microextraction Coupled to Nano-Liquid Chromatography/Diode Array Detection

  • Prieto-Blanco, M. C.
  • Peñafiel Barba, S.
  • Moliner-Martínez, Yolanda
  • Campíns-Falcó, Pilar
This is an accepted version of the published document., [Abstract] In the present work, the footprint of carbonyl compounds in hand scent was achieved by a miniaturized method consisting of sampling with cotton gauze, extraction and derivatization using 2,4-dinitrophenylhydrazine (DNPH) and preconcentration, separation and detection by in-tube solid-phase microextraction (IT-SPME) coupled to nano-liquid chromatography/Uv–vis diode array detection. The coupling IT-SPME-nanoLC-DAD was solved by using a two-valve system: the first valve for loading the sample and the second one to perform IT-SPME. To this aim, a nanoparticle-based capillary column was employed. Firstly, the transfer time from the load loop to the NP-based capillary column in the IT-SPME system was optimized. Additionally, the conditioning and clean-up steps were also studied. For the chromatographic separation of DNPH derivatives, gradient elution mode (acetonitrile/water) and a C18 nanocolumn were employed. The detection limits achieved were between 0.5 and 1.5 μg/L and % rsd was lower than 5% for quantification limits. The proposed methodology gave rise to different chromatographic profiles of carbonyl compounds in the hand scent of several volunteers. These profiles were obtained by estimating the relative peak area of selected carbonyls in hand scent. Nonanal, decanal and dodecanal and other low polarity carbonyl compounds (unknown hydrazones) were detected in the odor profiles., The authors are grateful to the EU-FEDER/MINECO-AEI-Gobierno de España (CTQ2017-90082-P), Generalitat Valenciana (PROMETEO program 2012/045 and 2016/109), and the Program of Consolidation and Structuring of Units of Competitive Investigation of the University System of Galicia potentially co-financed by European Regional Development Fund (ERDF) in the frame of the operative Program of Galicia (Xunta de Galicia, reference: ED431C 2017/28). MCPB expresses their gratitude to the PROMETEO program for a grant for a research stay, Generalitat Valenciana; 2012/045, Generalitat Valenciana; 2016/109, Xunta de Galicia; ED431C 2017/28