Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Cadmium zinc telluride solid-state detector characterization for its use as a spectro-dosemeter

  • Kržanovic, Nikola
  • Röttger, Annette
  • Morosh, Viacheslav
  • Luchkov, Maksym
  • Neumaier, Stefan
Concerning ionising radiation monitoring in the environment in areas which, by normal means, are inaccessible, e.g. in contaminated areas after a nuclear or radiological incident, the use of highly mobile systems, comprising of unmanned airborne vehicles equipped with ionising radiation detector, is advised in order to protect the health and the life of first responders. As a promising candidate, the compact solid-state spectrometer based on CdZnTe is characterised by performing irradiations in the reference radionuclide radiation fields of PTB. The energydependent conversion coefficients are derived from recorded pulse-height spectra, and they enable calculation of the operational radiation protection quantity, ambient dose equivalent rate, directly from the spectrum without deconvolution. The validity of the conversion coefficients was evaluated by determining the deviation of the calculated dose rate from the reference ambient dose equivalent rate for the 226Ra radionuclide, available at the Underground Dosimetry Laboratory (UDO II) of PTB. By employing the derived conversion coefficients, the detector “linearity” (dose rate dependence of the response) was checked in the 137Cs reference fields of different ambient dose equivalent rates ranging from 25 nSv/h up to 1 µSv/h. The deviation of the calculated 226Ra dose rate from the achieved reference value was +2%, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Unmanned aircraft based gamma spectrometry system for radiological surveillance

  • Luchkov, Maksym
  • Neumaier, Stefan
  • Vargas Drechsler, Arturo
In the framework of the European “Preparedness” project, PTB is developing a spectrometer based dosimetric system that can be operated while being attached to an unmanned aerial vehicle (UAV). Built around 1.5" CeBr3 scintillation detector, the radiation monitoring system records spectra alongside with temperature and flight telemetry at 0.5 Hz acquisition rate and transmits these data to a ground station where an algorithm calculates dose rates and activities. The presented aerial test results illustrate system’s ability to precisely target a source and provide a good estimation of its activity., Peer Reviewed, Postprint (author's final draft)