Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i (R) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain

  • Millan-Lou, M.I.
  • Garcia-Lechuz, J.M.
  • Ruiz-Andres, M.A.
  • Lopez, C.
  • Aldea, M.J.
  • Revillo, M.J.
  • Rezusta, A.
Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an optimal cut-off value to be used in routine practice in our hospital. For the validation of the UF-1000i cytometer, precision, linearity and carry-over were studied in samples with different counts of bacteria, leukocytes and erythrocytes. Between March and June 2016, urine samples were tested in the Clinical Microbiology Laboratory at University Miguel Servet Hospital, in Spain. Samples were analyzed with the Sysmex UF-1000i cytometer, and cultured. Growth of >= 10(5) CFUs/mL was considered positive. The validation study reveals that the precision in all the variables is acceptable; that there is a good linearity in the dilutions performed, obtaining values almost identical to those theoretically expected; and for the carry-over has practically null values. A total of 1, 220 urine specimens were included, of which 213 (17.4%) were culture positive. The optimal cut-off point of the bacteria-leukocyte combination was 138.8 bacteria or 119.8 leukocytes with an S and E of 95.3 and 70.4%, respectively. The UF-1000i cytometer is a valuable method to screen urine samples to effectively rule out UTI and, may contribute to the reduction of unnecessary urine cultures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparing Two Automated Techniques for the Primary Screening-Out of Urine Culture

  • Millán-Lou, M. I.
  • García-Lechuz, J. M.
  • Ruiz-Andrés, M. A.
  • López, C.
  • Aldea, M. J.
  • Egido, P.
  • Revillo, M. J.
  • Rezusta, A.
Urinary tract infection is the most common human infection with a high morbidity. In primary care and hospital services, conventional urine culture is a key part of infection diagnosis but results take at least 24 h. Therefore, a rapid and reliable screening method is still needed to discard negative samples as quickly as possible and to reduce the laboratory workload. In this aspect, this study aims to compare the diagnostic performance between Sysmex OF-1000i and FUS200 systems in comparison to urine culture as the gold standard. From March to June 2016, 1, 220 urine samples collected at the clinical microbiology laboratory of the "Miguel Servet" hospital were studied in parallel with both analysers, and some technical features were evaluated to select the ideal equipment. The most balanced cut-off values taking into account bacteria or leukocyte counts were 138 bacteria/mu L or 119.8 leukocyte/pl for the OF-1000i (95.3% SE and 70.4% SP), and 5.7 bacteria/mu L or 4.3 leukocyte/mu L for the FUS200 (95.8% SE and 44.4% SP). The reduction of cultured plates was 37.4% with the FUS200 and 58.3% with the UF-1000i. This study shows that both techniques improve the workflow in the laboratory, but the OF-1000i has the highest specificity at any sensitivity and the FUS200 needs a shorter processing time.