ANALISIS HEMATOLOGICO Y TISULAR DE RESTOS DE DESGASTE DURANTE EL USO DE COCR FUNCIONALIZADO CON OXIDO DE GRAFENO REDUCIDO PARA APLICACIONES DE PROTESIS ARTICULARES. RESPUESTA

RTI2018-101506-B-C32

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Dataset for the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with gra-phene oxide and hyaluronic acid for joint prostheses"

  • Escudero Rincón, , María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, Rosa María
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
The dataset includes data on particle characterization of debris collected from wear-corrosion tests and blood analysis from rats after 30 days of inoculation. Particle size distribution of the debris was measured using a MasterSizer 3000 with laser diffraction technology. This device features a red He-Ne laser (wavelength: 632.8 nm), a blue LED laser (wavelength: 470 nm), and a Hydro SV small volume dispersion unit with stirring. Measurements were taken with laser obscuration set between 3% and 15%, and sample dispersion was achieved at 1200 rpm. Two debris samples were analyzed, each with three measurements. The dataset contains six files, each with two columns labeled "size" and "volume."Blood analysis was conducted prior to euthanizing the animals in a CO2 chamber, with 1.5 mL of intracardiac blood extracted. Serum samples were prepared by centrifugation at 3,000 x g for 15 minutes, then separated and stored in 1.5 mL Eppendorf tubes in a cold chamber for transport to a laboratory. Hematological analysis was performed by UNILABS (Madrid, Spain) using a Sysmex Kx-21n hematology autoanalyzer (Sysmex Corporation, Kobe, Japan). The dataset file consists of 21 columns, detailing results by treatment group (Serum control, Hyaluronic acid, and Graphene) and particle concentrations (0.63 mg/ml, 1.83 mg/ml, 1.65 mg/ml, and 2.35 mg/ml). Hematological parameters in the dataset include hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count. Biochemical parameters measured in serum samples are creatinine (Crea), aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LDH), total protein (TP), triglycerides (TG), and cholesterol (CHO). Coagulation parameters include prothrombin time (PT), thromboplastin time (TT), and fibrinogen (F)., [EN] This is the experimental dataset used in the paper "Hematological response to particle debris generated during wear–corrosion processes of CoCr surfaces modified with graphene oxide and hyaluronic acid for joint prostheses". The paper includes the results of the potential biological responses and consequences of wear-corrosion processes associated with CoCr surfaces modified with graphene oxide and hyaluronic acid (CoCr-GO-HA), through in vitro (macrophage cultures) and in vivo (rat models) assays. Once the graphene oxide functionalized with hyaluronic acid was deposited on CoCr surfaces, wear-corrosion tests were performed by applying a 5N load at a rotational speed of 120 rpm over 30,000 m (682,000 cycles) in an aqueous solution of 3 g/L hyaluronic acid (HA), continuously recirculated during the experiment. The generated particles were collected and redispersed in 0.9% NaCl at concentrations of 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL, and 2.35 mg/mL. The particles were intra-articularly injected into the knees of rats. This dataset includes the results of the wear particle characterization and the hematological analysis and biochemical parameters, 30 days after intra-articular knee injection in rats. Whole-blood hematological parameters included hemoglobin (Hgb), hematocrit (Hct), white blood cell (WBC) count, red blood cell (RBC) count, mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), and platelet (PLT) count., [ES] Este es el conjunto de datos experimentales utilizado en el artículo "Respuesta hematológica a los desechos de partículas generados durante los procesos de desgaste-corrosión de superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico para prótesis articulares". El artículo incluye los resultados de las posibles respuestas biológicas y consecuencias de los procesos de desgaste-corrosión asociados con superficies de CoCr modificadas con óxido de grafeno y ácido hialurónico (CoCr-GO-HA), mediante ensayos in vitro (cultivos de macrófagos) e in vivo (modelos de ratas). Una vez depositado el óxido de grafeno funcionalizado con ácido hialurónico sobre superficies de CoCr, se realizaron ensayos de desgaste-corrosión aplicando una carga de 5N a una velocidad de rotación de 120 rpm durante 30,000 m (682,000 ciclos) en una solución acuosa 3 g/L de ácido hialurónico (HA), recirculada continuamente durante el experimento. Las partículas generadas se recogieron y se redispersaron en NaCl al 0.9%, a concentraciones de 0.63 mg/mL, 1.65 mg/mL, 1.83 mg/mL y 2.35 mg/mL. Las partículas fueron inyectadas intra-articularmente en rodilla de ratas. Este conjunto de datos incluye los resultados de la caracterización de partículas generadas durante los experimentos de desgaste-corrosión y los análisis hematológicos y parámetros bioquímicos después de 30 días de la inyección intraarticular en las rodillas de las ratas. Los parámetros hematológicos de sangre completa incluyeron hemoglobina (Hgb), hematocrito (Hct), conteo de glóbulos blancos (WBC), conteo de glóbulos rojos (RBC), volumen corpuscular medio (MCV), concentración media de hemoglobina corpuscular (MCHC) y conteo de plaquetas (PLT)., Ministerio de Ciencia e Innovación (MCIN), No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear–Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero Rincón, María Lorenza
  • García-Alonso, M. C.
  • Chico, Belén
  • Lozano, R.M.
  • Sánchez-López, Luna
  • Flores-Sáenz, Manuel
  • Cristóbal-Aguado, Soledad
  • Moreno-Gómez-Toledano, Rafael
  • Aguado-Henche, Soledad
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., This wok was supported by RTI2018-101506-B-C31, RTI2018-101506-B-C32 and RTI2018-101506-B-C33 projects funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ERDF A way of making Europe”. Grant PRE2019-090122 was funded by MCIN/AEI/10.13039/501100011033/ from Ministerio de Ciencia, Innovación y Universidades and by “ESF Investing in your future”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Intra-Articular Injection in Wistar Rats: Standardization and Experimental Validation of a Precise Protocol for Nanomaterial Administration

  • Flores-Sáenz, Manuel
  • Chico, Belén
  • García Alonso, María
  • Clemente de Arriba, Celia
  • Aguado-Henche, Soledad
This article belongs to the Special Issue The Future of Nanotechnology: Healthcare and Manufacturing., [Background:] Intra-articular injection is a fundamental technique in preclinical research for evaluating therapeutics and inducing joint disease models in rodents. However, the absence of standardized and validated protocols compromises reproducibility and translational validity., [Methods:] This study establishes and experimentally validates a refined protocol for precise intra-articular injection in the knee of adult male Wistar rats. The comprehensive procedure specifies anatomical landmarks (medial border of the patellar tendon), instrumentation (27 G needle, 100 µL Hamilton syringe), a maximum volume of 35 µL, and operative verification criteria based on tactile feedback. Experimental validation was performed by administering a suspension of wear particles (2.35 mg/mL) generated from tribocorrosion tests of CoCr surfaces biofunctionalized with graphene oxide-hyaluronic acid (GO-HA) into the left knee of five rats., [Results:] Histological analysis using the cutting–grinding technique and Toluidine Blue staining confirmed the exclusive intra-articular localization of particles in all injected animals (5/5 success rate). Qualitative assessment revealed abundant particulate distribution within the synovial space, with numerous individual particles and multiple aggregates observed per high-power field, without evidence of extravasation in any case., [Conclusions:] The protocol demonstrated high intra-operator repeatability and provides a reliable, ethically refined tool for precise intra-articular administration of nanomaterials and for generating robust joint disease models, thereby enhancing reproducibility and animal welfare in preclinical research., This research was funded by the Spanish State Research Agency (Agencia Estatal de Investigación, AEI), grant number RTI2018-101506-B-C32, RTI2018-101506-B-C31. The APC was funded by the Department of Surgery, Medical and Social Sciences, Faculty of Medicine and Health Sciences, University of Alcalá., Peer reviewed
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Hematological Response to Particle Debris Generated During Wear-Corrosion Processes of CoCr Surfaces Modified with Graphene Oxide and Hyaluronic Acid for Joint Prostheses

  • Escudero, María L.
  • García Alonso, María C.
  • Chico, Belén
  • Lozano, Rosa M.
  • Sánchez López, Luna
  • Flores Sáenz, Manuel
  • Cristobal Aguado, Soledad|||0009-0006-5199-9557
  • Moreno Gómez-Toledano, Rafael Felipe|||0000-0002-4834-289X
  • Aguado Henche, Salud Soledad|||0000-0003-2188-3618
Various surface modifications to increase the lifespan of cobalt–chromium (CoCr) joint prostheses are being studied to reduce the wear rate in bone joint applications. One recently proposed modification involves depositing graphene oxide functionalized with hyaluronic acid (a compound present in joints) on CoCr surfaces, which can act as a solid lubricant. This paper analyzes the biological alterations caused by wear–corrosion phenomena that occur in joints, both from the perspective of the worn surface (in vitro model) and the particles generated during the wear processes (in vivo model). The analysis of the inflammatory response of macrophage was performed on CoCr surfaces modified with graphene oxide and functionalized with hyaluronic acid (CoCr-GO-HA), before and after wear–corrosion processes. The wear particles released during the wear–corrosion tests of the CoCr-GO-HA/CoCr ball pair immersed in 3 g/L hyaluronic acid were intra-articularly injected into the experimental animals. The hematological analysis in vivo was made considering a murine model of intra-articular injection into the left knee in male adult Wistar rats, at increasing concentrations of the collected wear particles dispersed in 0.9% NaCl. Non-significant differences in the inflammatory response to unworn CoCr-GO-HA surfaces and control (polystyrene) were obtained. The wear–corrosion of the CoCr-GO-HA disk increased the inflammatory response at both 72 and 96 h of material exposure compared to the unworn CoCr-GO-HA surfaces, although the differences were not statistically significant. The pro-inflammatory response of the macrophages was reduced on the worn surfaces of the CoCr modified and functionalized with graphene oxide (GO) and hyaluronic acid (HA), compared to the worn surfaces of the unmodified CoCr. The hematological analysis and tissue reactions after intra-articular injection did not reveal pathological damage, with average hematological values recorded, although slight reductions in creatinine and protein within non-pathological ranges were found. Some traces of biomaterial particles in the knee at the highest concentration of injected particles were only found but without inflammatory signs. The results show the potential benefits of using graphene in intra-articular prostheses, which could improve the quality of life for numerous patients., Agencia Estatal de Investigación, Ministerio de Ciencia e Innovación