Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Reverse shoulder arthroplasty: methodology improvement through personalized modelling techniques and FDM technology

  • Piles, Laura
  • Reig-Pérez, Miguel Jorge|||0000-0003-0226-1194
  • Segui Llinares, Vicente Jesús|||0000-0002-4043-2866
  • Pla-Ferrando, R|||0000-0001-6688-9904
[EN] Reverse shoulder arthroplasty (RSA) is a surgical technique that relieves pain and functional incapacity in certain shoulder pathologies. Adequate sizing and positioning parameters are very sensitive to each individual patient's shoulder features, such as: degenerative stage and glenoid morphology among others. The interplay of different shoulder features is often nuanced, nontrivial, and highly nonlinear. Therefore, general guidelines can often fall short at delivering the best possible clinical outcomes. To overcome this, a new trend uses imaging techniques to manufacture bespoke mechanical guiding tools customized to each patient's shoulder features. The application of FDM technologies allows doctors to obtain physical models of the patient's bone geometry in anticipation of surgery and, consequently, the manufacturing of a patient-specific guide to be used to guarantee the correct position of the glenoid base plate during surgery. This paper focuses on the design and further manufacturing process developing a protocol that controls and minimizes the manufacturing deviations, in order to get to the optimal product design using the patient's Computed Tomography (CT) information. The modelling and parametrization of the customized guide is based on the study and optimization of the bone reconstruction as well as the variables of the manufacturing process. In this research both the CAD information analysis and the FDM process are focused on the application of new design techniques and the optimization of bones geometry analysis in order to obtain a specific surgery guiding tool to be manufactured by FDM with limited deviations., The authors wish to acknowledge the support and assistance of Dr. Fernando Martínez, Consultant at the Hospital San Juan (Alicante, Spain) for his assistance in the medical analysis of the arthropathy. This work was funded by the Polisabio Funding (UPV-Fisabio 2017).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Reverse engineering applied to biomodelling and pathological bone manufacturing using FDM technology

  • Laura Piles
  • Fernando Martínez
  • José Miguel Seguí
  • Reig-Pérez, Miguel Jorge|||0000-0003-0226-1194
  • Segui Llinares, Vicente Jesús|||0000-0002-4043-2866
  • Pla-Ferrando, R|||0000-0001-6688-9904
[EN] Reverse engineering and medical image-based modeling technologies allow manufacturing of 3D biomodels of anatomical structures of human body. These techniques are based on anatomical information from scanning data such as CT and MRI, whose scanners are used for scanning data acquisition of the external and internal geometry of anatomical structures. These 3D biomodels have many medical applications such surgical training, preoperative planning, surgical simulation, diagnosis and treatments. 3D virtual models of human body structures based on CT are increasingly being used in clinical practice. A data processing methodology is required to obtain an accurate 3D model suitable for manufacturing using AM, and specially the FDM technologies. This study shows a step-by-step methodology to process the CT information in bounded uncertainty conditions in order to obtain the STL models of the degenerated bone components, and to manufacture the 3D biomodels for surgery analysis with optimal design and details, and with an adequate accuracy to ensure proper results by surgeons analysis., The authors wish to acknowledge the support of Ms. Jerica Risent and Mr. Joan Ortiz of Ford Motor Company for his assistance in the scanning of printed models. This work was supported by the Polisabio Funding (UPV-Fisabio 2017)