Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

New characterization methodology for vapor-injection scroll compressors

  • Tello-Oquendo, Fernando M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] This paper presents a characterization methodology for vapor-injection scroll compressors (SCVI). An SCVI was characterized in a modified calorimetric test bench, which is able to control the intermediate pressure and the injection superheat independently. Based on the characterization results, the injection mass flow rate was correlated with the intermediate pressure through a linear expression, and a modified AHRI polynomial was proposed to estimate the compressor power input. The correlations were used in a simple model to predict the intermediate conditions of the SCVI installed in a heat pump prototype with an economizer. The deviations obtained for the evaporator mass flow rate, injection mass flow rate, intermediate pressure, and compressor power input were lower than 5% in all cases. The proposed methodology allows evaluating SCVI in a wide range of operating conditions, being only dependent on compressor characteristics and totally independent of the system in which it is installed., Fernando M. Tello-Oquendo acknowledges the financial support provided by the "CONVOCATORIA ABIERTA 2013-SEGUNDA EASE" program, which was funded by the SENESCYT ("Secretaria Nacional de Educacion Superior, Ciencia, Tecnologia e Innovacion") (Grant No. 2015-AR37665) of Ecuador.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparison of the performance of a vapor-injection scroll compressor and a two-stage scroll compressor working with high pressure ratios

  • Tello-Oquendo, Fernando M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] This paper presents a comparative analysis of the performance of a vapor-injection scroll compressor (SCVI) and a two-stage scroll compressor (TSSC) working with high pressure ratios in heat pump applications. Semi-empirical models of the compressors are implemented. The models are adjusted with experimental data obtained in a calorimetric test bench. The optimum displacement ratio (DR) is analyzed considering two criteria, COP maximization, and discharge temperature minimization. Once defined the optimum DR, a systematic comparison of the compressors is performed in terms of compressor efficiencies, heating capacity, COP, and discharge temperature. Finally, the intermediate pressure is optimized for a high-temperature water heating application, taking into account heat sink of finite capacity. Results show that the optimum DR of TSSC is around 0.58 and the COP is 6% larger than that the SCVI at the nominal point. Considering a wide range of operating conditions, the SCVI presents better efficiency and COP for pressure ratios below 5. For higher-pressure ratios, the TSSC presents better performance and achieves lower discharge temperature. The heating capacity of the TSSC can be improved by 7% by varying the swept volume of the high-stage compressor compared with the SCVI, with a minimum effect on the COP and on the discharge temperature from the optimum conditions., Fernando M. Tello-Oquendo acknowledges the financial support provided by the CONVOCATORIA ABIERTA 2013-SEGUNDA FASE program, which was funded by the SENESCYT (Secretaría de Educación Superior, Ciencia, Tecnología e Innovación) (Grant No. 2015-AR37665) of Ecuador. The authors would like to acknowledge Emerson Commercial and Residential Solutions for the given support to obtain the experimental data of scroll compressors and testing. In addition, the authors acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD , through the project ref-ENE2017-83665-C2-1-P Maximización de la eficiencia y minimización del impacto ambiental de bombas de calor para la descarbonización de la calefacción/ACS en los edificios de consumo casi nulo for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Semi-empirical model of scroll compressors and its extension to describe vapor-injection compressors. Model description and experimental validation, Modélisation semi-empirique de compresseurs à spirale et ses extensions pour décrire les compresseurs à injection de vapeur. Description du modèle et la validation expérimentale

  • Tello-Oquendo, Fernando
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Barceló Ruescas, Francisco|||0000-0002-0577-2662
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] This paper presents a semi-empirical model of scroll compressors and proposes a methodology in order to extend this model to vapor-injection scroll compressors. The model takes into account the ideal evolution of the refrigerant throughout the compressor and considers the main sources of losses in the compression process. The model is able to predict the compressor and volumetric efficiencies in terms of ten empirical parameters, which have a direct physical interpretation. For the model validation, a series of four non-injected scroll compressors of different capacities were tested using R-290 and a scroll compressor with vapor-injection (SCVI) was characterized using R-407C. Results show a correct agreement between the experimental and calculated compressor efficiencies, with a maximum deviation of ±5%. Furthermore, the model estimates accurately the discharge temperature of the refrigerant, compressor power input, and refrigerant mass flow rate in the suction and injection port. Finally, the SCVI model response was evaluated by varying the intermediate pressure and the injection superheat., Fernando M. Tello-Oquendo acknowledges the financial support provided by the CONVOCATORIA ABIERTA 2013-SEGUNDA FASE program, which was funded by the SENESCYT (Secretaría de Educación Superior, Ciencia, Tecnología e Innovación) (Grant No 2015-AR37665) of Ecuador. The authors would like to acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD , through the project ref-ENE2017-83665-C2-1-P Maximización de la eficiencia y minimización del impacto ambiental de bombas de calor para la descarbonización de la calefacción/ACS en los edificios de consumo casi nulo for the given support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A comprehensive study of two-stage vapor compression cycles with vapor-injection for heating applications, taking into account heat sink of finite capacity

  • Tello Oquendo, Fernando M.
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
  • Gonzálvez-Maciá, José|||0000-0001-9422-7756
[EN] This paper presents a comprehensive study of two-stage vapor compression cycles with vapor-injection for several refrigerants considering that the heat sink has a limited capacity. The key parameters of the cycle performance are identified and the influence of these parameters on the heating COP is analyzed. The optimum intermediate conditions of the cycle are evaluated using a general model of the cycle, considering two configurations (flash tank and economizer). Based on the optimization results, a correlation is proposed in order to estimate the optimum intermediate pressure, taking into account the temperature lift in the secondary fluid imposed by the application. The correlation uses cycle subcooling as an input, which is a novelty from the current correlations proposed in the literature. In addition, an optimum subcooling control strategy is proposed and finally, the influence of the size of the system components on the COP is studied., Fernando M. Tello-Oquendo acknowledges the financial support provided by the CONVOCATORIA ABIERTA 2013-SEGUNDA FASE program, which was funded by the SENESCYT (Secretaria de Educacion Superior, Ciencia, Tecnologia e Innovacion) (Grant no. 2015-AR37665) of Ecuador.