Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

ENERWATER - A standard method for assessing and improving the energy efficiency of wastewater treatment plants

  • Longo, Stefano
  • Mauricio Iglesias, Miguel
  • Soares, Ana
  • Campo, Pablo
  • Fatone, Francesco
  • Eusebi, Anna Laura
  • Akkersdijk, Erik
  • Stefani, Linda
  • Hospido Quintana, Almudena
This paper describes the first methodology specifically tailored to estimate energy efficiency at wastewater treatment plants (WWTPs). Inspired by the cycle of continuous improvement, the method (i) precisely defines the concept of energy efficiency in WWTPs, (ii) proposes systematic and comparable ways to measure it, and (iii) allows benchmarking and diagnosing energy hotspots. The methodology delivers an aggregated measure of the WWTP energy efficiency defined as the Water Treatment Energy Index, a single energy label that uses universally known illustrations enabling wide communication of standardized information on the WWTP energy status. The accuracy, reproducibility and generality of the methodology were validated by a widespread energy benchmarking method, and a case study is presented to show its capabilities. By promoting dialogue towards the creation of a specific European Standard, the actions accomplished by the H2020 Coordination Support Action ENERWATER should positively contribute to improving the exchange of information on energy saving actions and results between wastewater utilities and towards other stakeholders
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Is SCENA a good approach for side-stream integrated treatment from an environmental and economic point of view?

  • Longo, Stefano
  • Frison, Nicola
  • Renzi, Daniele
  • Fatone, Francesco
  • Hospido Quintana, Almudena
The environmental and economic benefits and burdens of including the first Short Cut Enhanced Nutrient Abatement (SCENA) into a real municipal wastewater treatment plant were evaluated using life cycle assessment (LCA) and life cycle cost (LCC). The implications of accomplishing nitrogen (N) removal and phosphorus (P) recovery via nitrite in the side stream were assessed taking into account the actual effluent quality improvement, the changes in the electricity and chemical consumption, N2O, CO2 and CH4 emissions and the effects of land application of biosolids, among others. In addition, a case-specific estimation of the P availability when sludge is applied to land, therefore replacing conventional fertilizer, was performed. Furthermore, to account for the variability in input parameters, and to address the related uncertainties, Monte Carlo simulation was applied. The analysis revealed that SCENA in the side stream is an economic and environmentally friendly solution compared to the traditional plant layout with no side-stream treatment, thanks to the reduction of energy and chemical use for the removal of N and P, respectively. The uncertainty analysis proved the validity of the LCA results for global warming potential and impact categories related to the consumption of fossil-based electricity and chemicals, while robust conclusions could not be drawn on freshwater eutrophication and toxicity-related impact categories. Furthermore, three optimization scenarios were also evaluated proving that the performance of the WWTP can be further improved by, for instance, substituting gravitational for mechanical thickening of the sludge or changing the operational strategy to the chemically enhanced primary treatment, although this second alternative will increase the operational cost by 5%. Finally, the outcomes show that shifting P removal from chemical precipitation in the main line to biologically enhanced uptake in the side stream is key to reducing chemicals use, thus the operational cost, and increasing the environmental benefit of synthetic fertilizers replacement
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Monitoring and diagnosis of energy consumption in wastewater treatment plants. A state of the art and proposals for improvement

  • Longo, Stefano
  • D'Antoni, Benedetto Mirko
  • Bongards, Michael
  • Chaparro, Antonio
  • Cronrath, Andreas
  • Fatone, Francesco
  • Lema Rodicio, Juan Manuel
  • Mauricio Iglesias, Miguel
  • Soares, Ana
  • Hospido Quintana, Almudena
In response to strong growth in energy intensive wastewater treatment, public agencies and industry began to explore and implement measures to ensure achievement of the targets indicated in the 2020 Climate and Energy Package. However, in the absence of fundamental and globally recognized approach evaluating wastewater treatment plant (WWTP) energy performance, these policies could be economically wasteful. This paper gives an overview of the literature of WWTP energy-use performance and of the state of the art methods for energy benchmarking. The literature review revealed three main benchmarking approaches: normalization, statistical techniques and programming techniques, and advantages and disadvantages were identified for each one. While these methods can be used for comparison, the diagnosis of the energy performance remains an unsolved issue. Besides, a large dataset of WWTP energy consumption data, together with the methods for synthesizing the information, are presented and discussed. It was found that no single key performance indicators (KPIs) used to characterize the energy performance could be used universally. The assessment of a large data sample provided some evidence about the effect of the plant size, dilution factor and flowrate. The technology choice, plant layout and country of location were seen as important elements that contributed to the large variability observed
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Transient and Persistent Energy Efficiency in the Wastewater Sector based on Economic Foundations

  • Longo, Stefano
  • Chitnis, Mona
  • Mauricio Iglesias, Miguel
  • Hospido Quintana, Almudena
Given the increasing importance of the wastewater sector in terms of energy usage, the understanding of the level of energy efficiency of wastewater treatment plants (WWTPs) is useful to both the industry itself as well as policy makers. Here, based on economic foundations, we apply a Stochastic Frontier Analysis (SFA) approach for energy demand modelling to estimate energy efficiency in the wastewater sector. Using specific SFA models and panel data from 183 Swiss WWTPs over the period 2001 to 2015, the paper illustrates that distinguishing between persistent and transient inefficiency is essential to deduce appropriate energy efficiency diagnosis in WWTPs. In this respect, persistent energy inefficiency is found to be more severe than transient energy inefficiency. Furthermore, it is shown that the age of the equipment influences the demand for energy and the energy savings due to technological innovation are quantified. Finally, economies of output density and scale are estimated demonstrating that for plants operating below optimal scale significant energy savings can be achieved if plants would be operated at higher size. Instead, our analysis reveals also that for plants larger than 100000 Population Equivalent, at least from an energy efficiency point of view, it would be no more beneficial to increase their scale.
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Energy efficiency in wastewater treatment plants: A framework for benchmarking method selection and application

  • Longo, Stefano
  • Hospido Quintana, Almudena
  • Mauricio Iglesias, Miguel
Utilities produce and store vast amount of data related to urban wastewater management. Not yet fully exploited, proper data analysis would provide relevant process information and represents a great opportunity to improve the process performance. In the last years, several statistical tools and benchmarking methods that can extract useful information from data have been described to analyse wastewater treatment plant (WWTP) energy efficiency. Improving energy efficiency at WWTPs is however a complex task which involves several actors (both internal and external to the water utility), requires an exchange of different types of information which can be analysed by a broad selection of methods. Benchmarking method therefore must not only be selected based on whether they provide a clear identification of inefficient processes; it must also match the available data and the skills of those performing the assessment and objectives of stakeholders interpreting the results. Here, we have identified the requirements of the most common benchmarking methods in terms of data, resources, complexity of use, and information provided. To do that, inefficiency is decomposed so that the analyst, considering the objective of the study and the available data, can link each element to the appropriate method for quantification and benchmarking, and relate inefficiency components with root-causes in wastewater treatment. Finally, a framework for selecting the most suitable benchmarking method to improve energy efficiency in WWTPs is proposed to assist water sector stakeholders. By offering guidelines on how integrates and links data, methods and actors in the water sector, the outcomes of this article are expected to move WWTPs towards increasing energy efficiency
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Designing a robust index for WWTP energy efficiency: the ENERWATER Water Treatment Energy Index

  • Mauricio Iglesias, Miguel
  • Longo, Stefano
  • Hospido Quintana, Almudena
The development and use of composite indexes has exploded in the last 15 years as a tool to summarise the large amount of information available nowadays. To ensure that composite indicators reflect faithfully the purpose of evaluation and are widely accepted and used, the users must understand the relationship between individual sub-indicators and the result (transparency) and the evaluation should not depend on weights, lack of information, etc. (robustness). It is proposed here for the first time a composite index to measure energy efficiency in a wastewater treatment plant, from the definition of the individual sub-indicators to the assignation of an energy label, easy to communicate to a broad public. Using as a demonstration real data from 44 wastewater treatment plants, the index robustness is tested and improved by uncertainty and sensitivity analysis results, finally achieving a robust algorithm which can be used by the large majority of wastewater treatment plants
Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

A systematic methodology for the robust quantification of energy efficiency at wastewater treatment plants featuring Data Envelopment Analysis

  • Longo, Stefano
  • Hospido Quintana, Almudena
  • Lema Rodicio, Juan Manuel
  • Mauricio Iglesias, Miguel
This article examines the potential benefits of using Data Envelopment Analysis (DEA) for conducting energy-efficiency assessment of wastewater treatment plants (WWTPs). WWTPs are characteristically heterogeneous (in size, technology, climate, function ...) which limits the correct application of DEA. This paper proposes and describes the Robust Energy Efficiency DEA (REED) in its various stages, a systematic state-of-the-art methodology aimed at including exogenous variables in nonparametric frontier models and especially designed for WWTP operation. In particular, the methodology systematizes the modelling process by presenting an integrated framework for selecting the correct variables and appropriate models, possibly tackling the effect of exogenous factors. As a result, the application of REED improves the quality of the efficiency estimates and hence the significance of benchmarking. For the reader's convenience, this article is presented as a step-by-step guideline to guide the user in the determination of WWTPs energy efficiency from beginning to end. The application and benefits of the developed methodology are demonstrated by a case study related to the comparison of the energy efficiency of a set of 399 WWTPs operating in different countries and under heterogeneous environmental conditions