Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

BIRD. BCAM's Institutional Repository Data
Publicación Artículo científico (JournalArticle)

High-order mixed weighted compact and non-compact scheme for shock and small length scale interaction

  • Stipcich, G.
  • Fu, H.
  • Liu, C.
It is critical for a numerical scheme to obtain numerical results as accurate as possible with limited computational resources. Turbulent processes are very sensitive to numerical dissipation, which may dissipate the small length scales. On the other hand, dealing with shock waves, capturing and reproducing of the discontinuity may lead to non-physical oscillations for non-dissipative high-order schemes. In the present work, a new high-order mixed weighted compact and non-compact difference scheme (MWCS hereafter) is proposed for accurate approximation of the derivatives in the governing Euler equations. The basic idea is to recover the non-dissipative high-order weighted compact scheme (WCS) in smooth regions, while linearly combine the WCS with a non-compact scheme, the weighted essentially non-oscillatory (WENO) scheme, for near-shock areas, by using a shock-detecting function. The proposed formulation does not involve any case-dependent adjustable parameter. A detailed Fourier and local truncation error analysis are used for assessing the dispersion and dissipation characteristics of the scheme. Numerical tests are performed for the one- and two-dimensional case and the results are compared with the well-established WENO scheme and the WCS.
BIRD. BCAM's Institutional Repository Data
Publicación Artículo científico (JournalArticle)

A computational model of open-irrigated radiofrequency catheter ablation accounting for mechanical properties of the cardiac tissue

  • Petras, A.
  • Leoni, M.
  • Guerra Ramos, J.M.
  • Jansson, J.
  • Gerardo-Giorda, L.
Radiofrequency catheter ablation (RFCA) is an effective treatment for cardiac arrhythmias. Although generally safe, it is not completely exempt from the risk of complications. The great flexibility of computational models can be a major asset in optimizing interventional strategies, if they can produce sufficiently precise estimations of the generated lesion for a given ablation protocol. This requires an accurate description of the catheter tip and the cardiac tissue. In particular, the deformation of the tissue under the catheter pressure during the ablation is an important aspect that is overlooked in the existing literature, that resorts to a sharp insertion of the catheter into an undeformed geometry. As the lesion size depends on the power dissipated in the tissue, and the latter depends on the percentage of the electrode surface in contact with the tissue itself, the sharp insertion geometry has the tendency to overestimate the lesion obtained, especially when a larger force is applied to the catheter. In this paper we introduce a full 3D computational model that takes into account the tissue elasticity, and is able to capture the tissue deformation and realistic power dissipation in the tissue. Numerical results in FEniCS-HPC are provided to validate the model against experimental data, and to compare the lesions obtained with the new model and with the classical ones featuring a sharp electrode insertion in the tissue., La Caixa 2016 PhD grant to M. Leoni, and Abbott non-conditional grant to J.M. Guerra Ramos