Pasar al contenido principal

APLICACIONES AVANZADAS DE SEPARACION. MODELADO Y VALIDACION EXPERIMENTAL

CTQ2015-66078-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario UNIVERSIDAD DE CANTABRIA
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Modeling the influence of divalent ions on membrane resistance and electric power in reverse electrodialysis

  • Gómez-Coma, Lucía
  • Ortiz-Martínez, Víctor M.
  • Carmona, Javier
  • Palacio, Laura
  • Prádanos, Pedro
  • Fallanza, Marcos
  • Ortiz, Alfredo
  • Ibáñez González, Raquel
  • Ortiz, Inmaculada
The prospects and potential of Reverse Electrodialysis (RED) for energy harvesting from natural streams with salinity gradient demand more in-depth studies to understand and overcome the limitations posed by divalent ions. Power performance is greatly influenced by the ionic resistance displayed by the alternating cation and anion exchange membranes (CEMs and AEMs, respectively) housed in RED stacks, which in turn is determined by the type and concentration of ions and counter-ions in the water streams. The effects of divalent ions on power output have been experimentally approached in several works by using real or synthetic water. However, the development of comprehensive models including the effect of divalent ions on membrane resistance and power performance under different scenarios is still very scarce. Thus, this work investigates experimentally the effect of ion species on membrane resistance, providing for the first time mathematical correlations useful to predict power performance in RED stacks under a wide range of compositions of salinity gradient solutions. To this end, electrochemical impedance spectroscopy (EIS) measurements have been performed for CEM and AEM commercial membranes in contact with different concentration of NaCl solutions and including different mixtures of divalent ions (Ca2+, Mg2+, SO42−). These correlations have been implemented in a previously developed model to determine power outputs as function of ion mixture compositions. Scenarios of general interest for RED practical implementation have been addressed; specifically, solutions with a composition representative of seawater or high salinity brines have been studied as high concentration solutions (HCS) and, on the other hand, typical concentrations of wastewater treatment plant effluents, river water or brackish water from desalination plants were used as low concentration solutions (LCS)., The authors want to acknowledge financial support from the Community of Cantabria - Regional Plan through the project: Gradisal “RM16-XX-046-SODERCAN/FEDER”, the projects funded by the Spanish Ministry of Economy and Competitiveness CTQ2015-66078-R, and CTM2017-87850-R and the project “HYLANTIC”- EAPA_204/2016, which is co-financed by the European Regional Development Fund in the framework of the Interreg Atlantic program. V.M. Ortiz-Martínez is supported by the Spanish Ministry of Science, Innovation and Universities (grant ‘Juan de la Cierva-Formación’ ref. FJCI-2017-32404).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Integrated strategy for the separation of endotoxins from biofluids. LPS capture on newly synthesized protein

  • Basauri, Arantza
  • Fallanza, Marcos
  • Giner Robles, Laura
  • Fernández López, Raúl
  • Moncalián, Gabriel
  • Cruz, Fernando de la
  • Ortiz, Inmaculada
Endotoxin, or lipopolysaccharide (LPS), is recognized as the most powerful microbial mediator implicated in the pathogenesis of sepsis, a life-threatening organ disfunction whose overall prognosis is still poor. Therefore, the need to detect and remove LPS has led some authors to focus their efforts on the design of pathogen cleansing microdevices. Micromagnetophoretic cleansing involves a first step for the selective binding and sequestration of LPS on non-toxic particles followed by the removal of the loaded particles from the fluid medium. While outstanding progress has been made in magnetic separation, the state of the art of the first step still needs to fill important gaps in knowledge to advance towards the development of detection systems. Thus, this work reports an integrated methodology to advance the design of the LPS sequestration stage to promote its separation from biofluids. The methodology combines protein and separation fundamentals and starts with the synthesis of an anti LPS factor protein (LALF), followed by the quantitative determination of its binding strength to LPS. For this analysis LALF was supported on agarose beads and the variables affecting LPS binding, as binding and capture temperature, the optimum bead:protein and protein:LPS ratios, have been experimentally studied. The methodology and results here reported constitute the information needed to advance the knowledge for the correct design of LPS separation devices., Financial assistance from the project RTI2018-093310-B-I00 (MINECO/FEDER, UE) is gratefully acknowledged. Arantza Basauri also thanks the FPI research (BES-2016-077206).