Pasar al contenido principal

TRIGENERACION CON LA HIBRIDACION DE ENERGIAS RENOVABLES Y DESALACION

ENE2014-59947-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2014
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario FUNDACION CIRCE CENTRO DE INVESTIGACION DE RECURSOS Y CONSUMOS ENERGETICOS
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dynamic simulation of a trigeneration scheme for domestic purposes based on hybrid techniques

  • Acevedo, Luis
  • Uche, Javier
  • Del Almo, Alejandro
  • Círez, Fernando
  • Usón, Sergio
  • Martínez, Amaya
  • Guedea, Isabel
In this paper, the design of a system providing electricity by coupling photovoltaic/thermal (PVT) collectors and a wind turbine (WT), sanitary hot water (SHW) coming from the PVT and evacuated tube collectors (ETCs) and fresh water (FW) produced in two seawater desalting facilities (membrane distillation, MD, and reverse osmosis, RO), has been carefully analyzed by means of a dynamic model developed in TRNSYS®. This analysis is compulsory to operate a lab-scale pilot plant that is being erected at Zaragoza, Spain. A new model-type has been included in TRNSYS® in order to include the MD unit in the scheme. A sensitivity analysis of some free-design variables, such that the ETC surface, PVT and ETC tilt, water storage tank, batteries capacities, and mass flow rates delivered to the SHW service and/or feeding the MD unit has been performed in order to propose the definite design of the scheme. The proposed base case was able to produce up to 15, 311 L per year in the MD system and cover an electric energy demand of 1890 kWh. Coverage of SHW, water (including RO and MD) and power is respectively 99.3%, 100% and 70%. However, daily and yearly assessment of FW, SHW and power produced with the optimized design gave a better coverage of water and energy demands for a typical single family home. The improved and definite design was able to increase its MD production in 35% and the electric energy in 7% compared with base case.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Improving the distillate prediction of a membrane distillation unit in a trigeneration scheme by using artificial neural networks

  • Acevedo, L.
  • Uche, J.
  • Del-Amo, A.
An Artificial Neural Network (ANN) has been developed to predict the distillate produced in a permeate gap membrane distillation (PGMD) module with process operating conditions (temperatures at the condenser and evaporator inlets, and feed seawater flow). Real data obtained from experimental tests were used for the ANN training and further validation and testing. This PGMD module constitutes part of an isolated trigeneration pilot unit fully supplied by solar and wind energy, which also provides power and sanitary hot water (SHW) for a typical single family home. PGMD production was previously estimated with published data from the MD module manufacturer by means of a new type in the framework of Trnsys® simulation within the design of the complete trigeneration scheme. The performance of the ANN model was studied and improved through a parametric study varying the number of neurons in the hidden layer, the number of experimental datasets and by using different activation functions. The ANN obtained can be easily exported to be used in simulation, control or process analysis and optimization. Here, the ANN was finally used to implement a new type to estimate the PGMD production of the unit by using the inlet parameters obtained by the complete simulation model of the trigeneration unit based on Renewable Energy Sources (RES).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Exergy assessment and exergy cost analysis of a renewable-based and hybrid trigeneration scheme for domestic water and energy supply

  • Usón, S.
  • Uche, J.
  • Martínez, A.
  • del Amo, A.
  • Acevedo, L.
  • Bayod, Á.
Exergy and exergy cost analyses are proposed as complementary methods for the assessment and better understanding of the efficiency of a hybrid trigeneration system based on renewable energy sources. The system combines photovoltaic/thermal collectors, an evacuated tube collector and a wind turbine and produces electricity, sanitary hot water and desalted fresh water for a single family house. The system includes two desalination technologies (reverse osmosis and membrane distillation) that consume power and heat respectively, and two kinds of energy storage devices (a hot water tank and two lead-acid batteries). The assessment is based on simulations developed by using TRNSYS software. As a first level of detail, exergy analysis is applied in ten-minute basis to selected plant components. As a second level of detail, it is proposed to apply exergy-based indicators that summarize the system behavior during a longer period of time (monthly basis). By using aggregated values, exergy accumulation terms become negligible, what allows applying symbolic thermoeconomics to calculate exergy cost and to analyze in depth the process of cost formation. The system has an exergy efficiency of 7.76% (6.68 due to electricity, 0.33 due to fresh water and 0.75 due to sanitary hot water).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analysis of a domestic trigeneration scheme with hybrid renewable energy sources and desalting techniques

  • Uche, J.
  • Acevedo, L.
  • Círez, F.
  • Usón, S.
  • Martínez-Gracia, A.
  • Bayod-Rújula, Á.A.
In this paper, experimental tests of a hybrid trigeneration pilot unit based on renewable energy sources are presented and analyzed. The plant provides electricity by coupling four photovoltaic/thermal collectors and a micro-wind turbine, fresh water by means of hybrid desalination (membrane distillation, and reverse osmosis), and sanitary hot water coming from the photovoltaic/thermal collectors and an evacuated tubes collector. Plant design was previously modeled to cover the power, freshwater and sanitary hot water for a typical family home (four residents) isolated from the power and water networks. The hybrid pilot unit has been tested from May 2017 to March 2018 in Zaragoza (Spain). Results from those tests show that daytime assessment of power, freshwater and sanitary hot water produced allowed a good coverage of scheduled energy and water demands. Flexible operation due to the combined production of power and heat was also observed. State of charge of the batteries and the temperature of the sanitary hot water tank are the key control variables, which allow to give priority to power, freshwater or sanitary hot water production according to the ordered demands or economic incentives. Environmental assessment of the pilot unit along its life cycle also has shown very low impacts with respect to the conventional supply of energy and water.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental tests to validate the simulation model of a Domestic Trigeneration Scheme with hybrid RESs and Desalting Techniques

  • Uche, J.
  • Muzás, A.
  • Acevedo, L. E.
  • Usón, S.
  • Martínez, A.
  • Bayod, A. A.
Experimental tests of a small polygeneration plant unit based on hybrid renewable energy and desalination have been used to validate a novel model simulation of this plant. It provides electricity by coupling photovoltaic/thermal collectors and a micro-wind turbine, fresh water by means of hybrid desalination (membrane distillation, and reverse osmosis), and sanitary hot water coming from the photovoltaic/thermal collectors and an evacuated tubes collector. Plant was designed to operate in off-grid conditions and conventional energy storage systems were used (lead acid batteries and hot water tank). Simulation model was performed in TRNSYS environment and it was fully validated by comparing several key plant measurements. The analysis was focused on five typical days of summer, fall and winter. Some differences found in experimental and simulated values were analysed. To reduce those gaps, some modifications have been suggested to the model or the pilot unit respectively. As a result, a validated model in TRNSYS of the plant was obtained. This model can be used for the further scale up of new projects to cover any other scheduled demands of power and water in isolated areas, whenever is based on the combination of the abovementioned technologies.