Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Comparative assessment of four ballast water compliance monitoring devices with natural UV-treated water using IMO's monitoring approaches

  • Romero Martínez, Leonardo
  • Van Slooten, Cees
  • Van Harten, Michiel
  • Nebot Sanz, Enrique
  • Peperzak, Louis
Compliance Monitoring Devices (CMDs) are instruments indicating if the 10–50 μ m organism abundance in ballast water complies with the International Maritime Organizations' discharge standard. For that, they trade the presumed accuracy of detailed methods for speed and simplicity. In an experiment using UV-treated water, four CMDs were compared, using a Cohen's kappa analysis (ISO 3725), with two detailed methods: Fluorescence Microscopy (FM) and the Most Probable Number (MPN). Of two CMDs, BallastWISE and B-QUA ATP, the standard (non)-compliance limits were adapted. Correlated to FM (non)-compliance results, ranking resulted in: 1) BallastWISE, 2) MPN, 3) Ballast-Check-2 and 4) WALZ-PAM. The ATP method had too few data for this ranking. MPN proved problematic: the abundance of 10–50 μ m organism decreased while that <10 m organisms increased. It is concluded that in case of UV-treatment, the outcome of CMD-validations will depend on the detailed method, the CMD instrument, and the (non)-compliance limits chosen.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Improving the microalgae inactivating efficacy of ultraviolet ballast water treatment in combination with hydrogen peroxide or peroxymonosulfate salt

  • Romero Martínez, Leonardo
  • Rivas Zaballos, Ignacio
  • Moreno Andrés, Javier
  • Moreno-Garrido, Ignacio
  • Acevedo Merino, Asunción
  • Nebot Sanz, Enrique
Due to the increasing number of ecosystem invasions with the introduction of exogenous species via ballast water, the International Maritime Organization adopted the Ballast Water Convention (BWMC). The BWMC establishes standards for the concentration of viable organisms in a ballast water discharge. Ultraviolet (UV) irradiation is commonly used for treating ballast water; however, regrowth after UV irradiation and other drawbacks have been reported. In this study, improvement in UV treatment with the addition of hydrogen peroxide or peroxymonosulfate salt was investigated using the microalgae Tetraselmis suecica as the target organism. Results reported that each of these reagents added in a concentration of 10 ppm reduced the concentration of initial cells by more than 96%, increased the UV inactivation rate, and enabled reaching greater level of inactivation with the treatment. These improvements imply a reduction of the UV doses required for a consistent compliance with the BWMC standards.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Development of a geometrical model for the determination of the average intensity in a flow-through UV-LED reactor and validation with biodosimetry and actinometry

  • Romero Martínez, Leonardo
  • Moreno Andrés, Javier
  • Acevedo Merino, Asunción
  • Nebot Sanz, Enrique
Ultraviolet (UV) treatment is widely used for water disinfection. The recent development and improvement of the light emitting diodes (LEDs) in the UVC range makes them an alternative to the traditional mercury vapor UV lamps in the middle or long term. Determining the UV intensity applied by a reactor is essential for evaluating its efficacy. Although doing so is relatively straightforward in simple laboratory reactors, such as a collimated beam reactor (CBR), its calculation for more complex devices, such as a flow-through reactor (FTR), requires indirect approaches. The objective in this study is determining the UV intensity in FTRs equipped with UV-C LEDs by utilizing indirect approaches such as the geometrical modeling of the intensity distribution, chemical actinom-etry, and biodosimetry using a CBR as a reference. With this method, the inactivation of four bacterial indicators in both the CBR and FTR have also been addressed. The three approaches that were used reported similar values of mean intensity with an average value of 0.86 mW cm-2. Determining the mean intensity enabled calculating the UV doses that were applied to the target water and then determining the inactivation kinetics parameters. The UV dose that was necessary to achieve four-log reductions from the initial bacterial concentration ranged from 5.8 to 17.5 mJ cm-2 depending on the target species. Additionally, the geometrical model developed in this study introduces new possibilities into the optimization of the reactor design.