Detector block performance based on a monolithic LYSO crystal using a novel signal multiplexing method

  • González, A.
  • Martí, Rosana
  • Hernández Hernández, Liczandro
  • Aguilar-Talens, Albert
  • BARBERA BALLESTER, JULIO
  • CATRET MASCARELL, JUAN VICENTE
  • Cañizares-Ledo, Gabriel
  • Conde-Castellanos, Pablo Eloy
  • Lamprou, Efthymios
  • Martos Pedrosa, Francisco
  • Sánchez-Góez, Sebastián
  • F Sánchez
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • González Martínez, Antonio Javier
[EN] Organ dedicated PET devices provide improved imaging performance when compared to whole body systems. The present study summarizes the test carried out to study a new detector block designed for an organ dedicated PET system. This block includes three novel components namely the scintillator geometry and a retroreflector layer coupled to the entrance face, the photosensor and the readout electronics. We used arrays of 12 x 12 SiPM photosensors with 3 x 3 mm(2) active area each and a pitch of 4.2 mm. We are proposing a new readout electronics that permits to reduce the 12 row and columns signals to only 8 without significant detector performance degradation. This approach also allows for resolving radioactive sources in the whole volume of the proposed crystal, significantly reducing the edge effect that typically rejects these events. An overall spatial resolution of about 1.8 mm FWHM is obtained for the whole scintillation volume, with an average energy resolution of 13% FWHM and a photon depth of interaction resolution (FWHM) of 3.7 mm. (C) 2018 Elsevier B.V. All rights reserved., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under Grant Nos. FIS2014-62341-EXP and TEC2016-79884-C2-1-R. This project has also received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement No. 711323. This project has received funding from the European Research Council (ERC) under the European Union s Horizon 2020 research and innovation programme (grant agreement No. 695536).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

PET detector block with accurate 4D capabilities

  • Lamprou, Efthymios
  • Aguilar -Talens, Albert
  • Gonzalez-Montoro, Andrea
  • Cañizares-Ledo, Gabriel
  • Iranzo-Egea, Sofía
  • Hernández Hernández, Liczandro
  • Conde-Castellanos, Pablo Eloy
  • Sánchez-Góez, Sebastián
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • F Sánchez
  • González Martínez, Antonio Javier
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this contribution, large SiPM arrays (8 x 8 elements of 6 x 6 mm(2) each) are processed with an ASIC-based readout and coupled to a monolithic LYSO crystal to explore their potential use for TOF-PET applications. The aim of this work is to study the integration of this technology in the development of clinical PET systems reaching sub-300 ps coincidence resolving time (CRT). The SiPM and readout electronics have been evaluated first, using a small size 1.6 mm (6 mm height) crystal array (32 x 32 elements). All pixels were well resolved and they exhibited an energy resolution of about 20% (using Time-over-Threshold methods) for the 511 keV photons. Several parameters have been scanned to achieve the optimum readout system performance, obtaining a CRT as good as 330 +/- 5 ps FWHM. When using a black-painted monolithic block, the spatial resolution was measured to be on average 2.6 +/- 0.5 mm, without correcting for the source size. Energy resolution appears to be slightly above 20%. CRT measurements with the monolithic crystal detector were also carried out. Preliminary results as well as calibration methods specifically designed to improve timing performance, are being analyzed in the present manuscript., This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation program (grant agreement No 695536). It has also been supported by the Spanish Ministerio de Economia, Industria y Competitividad under Grants No. FIS2014-62341-EXP and TEC2016-79884-C2-1-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A scintillator geometry suitable for very small PET gantries

  • González Martínez, Antonio Javier
  • F Sánchez
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Gonzalez-Montoro, A.
  • Aguilar, A.
  • Cañizares, G.
  • Martí, R.
  • Iranzo, S.
  • Lamprou, E.
  • Sánchez, S.
This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under Grants No. FIS2014-62341-EXP and TEC2016-79884-C2-1-R. This project has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (grant agreement No 695536).