Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RUC. Repositorio da Universidade da Coruña
Publicación Artículo científico (JournalArticle)

Circulating miR-181a-5p as a New Biomarker for Acute Cellular Rejection in Heart Transplantation

  • Constanso-Conde, Ignacio
  • Hermida-Prieto, Manuel
  • Barge-Caballero, Eduardo
  • Núñez Fernández, Lucía
  • Pombo-Otero, Jorge
  • Suárez-Fuentetaja, Natalia
  • Paniagua-Martín, María J.
  • Barge-Caballero, Gonzalo
  • Couto-Mallón, David
  • Pan Lizcano, Ricardo Francisco
  • Vázquez Rodríguez, José Manuel
  • Crespo-Leiro, María Generosa
[Abstract] Background: Acute cellular rejection (ACR) is a major complication in heart transplantation (HTx). Endomyocardial biopsy is the reference method for early detection of ACR, but a new non-invasive approach is needed. Tentative candidates could be circulating microRNAs. This study aimed to discover and validate microRNAs in serum for ACR detection after HTx. Methods: This prospective, observational, single-center study included 121 HTx patients. ACR was graded according to International Society of Heart and Lung Transplantation classification (0R−3R). First, in the discovery phase, microRNA expression profile was carried out in serum samples from patients at pre-rejection, during, and post-rejection time (0RS1 → 2RS2 → 0RS3). Relative expression (2-ΔCq) of 179 microRNAs per sample was analyzed by reverse transcription quantitative polymerase chain reaction. Second, a microRNA with a significant rise and fall pattern during ACR was selected for the next validation phase, where it was analyzed (reverse transcription quantitative polymerase chain reaction) in serum samples from 2 groups of patients: the no-ACR group (0R grade) and the ACR group (≥2R grade). Finally, a sensitivity analysis (receiver operating characteristic curve) was done to assess microRNA accuracy for ACR detection in HTx. Results: A total of 21 ACR episodes (0RS1 → 2RS2 → 0RS3) with their respective serum samples (n = 63) were included in the discovery phase. Among the 179 microRNAs analyzed, only miR-181a-5p met the rise and fall criteria. In the validation phase, miR-181a-5p relative expression (2-ΔCq) in the ACR group (n = 45) was significantly overexpressed (p < 0.0001) vs the no-ACR group (n = 45). miR-181a-5p showed an area under the curve of 0.804 (95% confidence interval: 0.707-0.880); sensitivity and specificity of 78% and 76%, respectively; and a negative predicted value of 98%., This study received financial support from Instituto de Salud Carlos III (PI15/02224), is part of the research activities of the Centro de investigación Biomédica en Red Enfermedades Cardiovasculares (CIBERCV), and was cofinanced with FEDER Funds