Pasar al contenido principal

NUEVOS MATERIALES AVANZADOS PARA SENSORES OPTICOS MULTIPARAMETRO

PID2019-106070RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Piezotronic, ZnO overlaid Bragg grating organic vapor sensors

  • López Torres, Diego
  • Elosúa Aguado, César
  • Pappas, Georgios A.
  • Konstantaki, Maria
  • Klini, Argyro
  • Lappas, Alexandros
  • Arregui San Martín, Francisco Javier
  • Pissadakis, Stavros
We present a zinc oxide (ZnO) out-cladding, overlaid optical fiber Bragg grating sensor, for the detection of vapors of common alcohols and acetone at concentrations lower than 25 ppm while operating at room temperature (RT). The optical fiber sensing results indicate a chemostriction effect occurring in the ZnO layer when exposed to volatile organic compounds (VOCs), which in turn induces shifts in the cladding, and most importantly, in the core confined, Bragg mode. The sensor exhibits a maximum sensitivity of ∼1 pm/ppm to ethanol vapors, with exposure to other alcohol vapors (isopropanol and methanol) showing lower sensitivities; also, response to acetone vapors was traced at ∼0.5 pm/ppm. X-ray diffraction (XRD) measurements of the ZnO nanolayer revealed that, in saturated ethanol vapors atmosphere, the polycrystalline ZnO film undergoes a contraction by 0.6% of the interplanar distance corresponding to the (002) crystalline direction, denoting the chemostrictive effect through an underlying piezotronic mechanism. XRD measurements and optical fiber sensing data are further correlated by numerical simulations carried out, so to study the strain interactions of the ZnO layer with the silica glass optical fiber., This work was supported in part by the Accelerating Photonics Deployment through the One Stop Shop Advanced Technology Access for Researchers (ACTPHAST 4R) Project under Grant 825051, in part by the Laserlab-Europe under Grant EU-H2020 871124, in part by the Spanish Government under Project PID2019-106070RB-I00, and in part by the NextGenerationEU - “Margarita Salas Program Grants” by the Public University of Navarre (UPNA).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

In situ synthesis of gold nanoparticles in layer-b y-layer polymeric coatings for the fabrication of optical fiber sensors

  • Martínez Hernández, María Elena
  • Goicoechea Fernández, Javier
  • Rivero Fuente, Pedro J.
  • Arregui San Martín, Francisco Javier
A new method is proposed to tune the interferometric response of wavelength-based optical fiber sensors. Using the nanoparticle in situ synthesis (ISS) technique, it is possible to synthesize gold nanoparticles (AuNPs) within a pre-existing polymeric thin film deposited at the end-face of an optical fiber. This post-process technique allows us to adjust the optical response of the device. The effect of the progressive synthesis of AuNPs upon polymeric film contributed to a remarkable optical contrast enhancement and a very high tuning capability of the reflection spectra in the visible and near-infrared region. The spectral response of the sensor to relative humidity (RH) variations was studied as a proof of concept. These results suggest that the ISS technique can be a useful tool for fiber optic sensor manufacturing., This research was funded by the Spanish Agencia Estatal de Investigación (AEI), grant number PID2019-106070RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Spectral measurements with hybrid LMR and SAW platform for dual parameter sensing

  • Domínguez Rodríguez, Ismel
  • Del Villar, Ignacio
  • Corres Sanz, Jesús María
  • Lachaud, Jean-Luc
  • Yang, Yang
  • Hallil, Hamida
  • Dejous, Corinne
  • Matías Maestro, Ignacio
Lossy mode resonance (LMR)-based optical sensors change their wavelength upon contact with substances or gases. This allows developing applications to detect the refractive index of the surrounding medium and even the thickness of the biolayers deposited on the waveguide. In the same way, when acoustic sensors are in contact with a liquid, it is possible to determine parameters, especially mechanical ones such as shape of the particle or molecule, mass load, elastic constants and viscosity of the liquid. This work reports the development of a system that combines LMR with surface acoustic wave (SAW) technologies to characterize a liquid in terms of its refractive index and viscosity simultaneously. Conveniently prepared glucose solutions are used for sensor calibration. The refractive index of the solutions ranges from 1.33 to 1.41 and its viscosity ranges from 1.005 mPa·s to 9 mPa·s, respectively. A sensitivity of 332 nm per RIU has been achieved with the optical sensor while the acoustic sensor has shown a sensitivity of −1.5 dB/(mPa·s). This new combinational concept could be expanded to the development of more demanding applications such as chemical sensors or biosensors., The authors would like to acknowledge the partial support to the Spanish Ministry of Economy and Competitiveness PID2019-106070RB-I00 and PID2019-106231RB-I00 research funds and the pre-doctoral research grant of the Public University of Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Multichannel refractometer based on lossy mode resonances

  • Fuentes Lorenzo, Omar
  • Corres Sanz, Jesús María
  • Domínguez Rodríguez, Ismel
  • Del Villar, Ignacio
  • Matías Maestro, Ignacio
In this work a new multiparameter sensor platform based on lossy mode resonances is presented. The structure consists of a soda-lime optical slab waveguide butt-coupled to multimode optical fibers. A variable thickness thin-film is deposited to generate multiple independent resonances on the same waveguide, which can be monitored using a single spectrometer. In order to show the potentiality of the structure, a broad resonance was selectively narrowed by etching sections of the LMR producer thin film. The spectral width is progressively reduced, allowing to selectively isolate independent resonances, which opens the path for multiple LMR generation in the same spectra in a multiparameter sensing platform. The experimental results were corroborated with a theoretical analysis based on the finite difference method (FDM). As a proof of concept, two refractometers on the same waveguide were fabricated and tested using PDMS cells. This platform can be easily miniaturized in order to integrate multiple sensors at low cost, what can be of interest for the development of multi-analyte biosensors probes. IEEE, This work was supported in part by the Spanish Ministry of Economy and Competitiveness under Grant PID2019-106070RB-I00 and Grant PID2019-106231RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Self-referenced optical fiber sensor based on LSPR generated by gold and silver nanoparticles embedded in layer-by-layer nanostructured coatings

  • Martínez Hernández, María Elena
  • Goicoechea Fernández, Javier
  • Rivero Fuente, Pedro J.
  • Sandúa Fernández, Xabier
  • Arregui San Martín, Francisco Javier
In this work, an optical fiber sensor based on the localized surface plasmon resonance (LSPR) phenomenon has been designed for the detection of two different chemical species (mercury and hydrogen peroxide) by using Layer-by-Layer Embedding (LbL-E) as a nanofabrication technique. In the first step, silver nanoparticles (AgNPs) and gold nanoparticles (AuNPs) have been synthesized by using a chemical protocol as a function of the strict control of three main parameters, which were polyelectrolyte concentration, a loading agent, and a reducing agent. In the second step, their incorporation into nanometric thin films have been demonstrated as a function of the number of bilayers, which shows two well-located absorption peaks associated to their LSPR in the visible region at 420 nm (AgNPs) and 530 nm (AuNPs). Finally, both plasmonic peaks provide a stable real-time reference measurement, which can be extracted from the spectral response of the optical fiber sensor, which shows a specific sensing mechanism as a function of the analyte of study., This research was funded by the Spanish Agencia Estatal de Investigación (AEI), grant number PID2019-106070RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Lossy mode resonance-based optical immunosensor towards detecting gliadin in aqueous solutions

  • Benítez Pérez, Melanys
  • Zubiate Orzanco, Pablo
  • Socorro Leránoz, Abián Bentor
  • Matías Maestro, Ignacio
The development of accurate, intuitive, and easy-to-handle devices to detect different types of allergens is on the rise, as these are useful tools to guarantee consumer safety, which should be a priority for any food industry. Gliadin, one of the main proteins present in gluten, is the one responsible for triggering the immune system to produce autoantibodies in celiac disease, the most dangerous pathology related to gluten. Lossy Mode Resonance (LMR) based biosensors are lately known as a promising sensing technology and its implementation on planar waveguides has been shown to result in manageable, sustainable and robust structures. In this work, an LMR based microfluidic biosensor for gliadin detection is proposed, by coating a coverslip with Titanium Dioxide (TiO2) by Atomic Layer Deposition (ALD) to generate the resonance phenomena and functionalizing the sensor surface with anti-gliadin antibody (AGA) through covalent bond. The sensor was exposed to different gliadin concentrations in ultrapure water, in the range of 0.1–100 ppm with an accuracy of ±0.14 ppm, for a sensitivity of 1.35 ppm/ml. The calibration curve was obtained from the experimental data corresponding to three repetitions of the assay and a limit of detection (LOD) of 0.05 ppm was achieved. Moreover, the sensor was exposed to commercial flour samples, some of them labeled as gluten free (GF) and the response agreed with the expected results according to product label. Biosensor specificity to gliadin was demonstrated by injecting chicken egg white albumin without obtaining any significant response., Authors would like to thank the partial funding by the Spanish Agencia Estatal de Investigacion (AEI) with references PID2019-106070RB-I00 and also by the Public University of Navarra, with the project BIOFOCEL (ref. PJUPNA2033) and a pre-doctoral research grant.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Simultaneous generation of surface plasmon and lossy mode resonances in the same planar platform

  • Fuentes Lorenzo, Omar
  • Del Villar, Ignacio
  • Domínguez Catena, Iris
  • Corres Sanz, Jesús María
  • Matías Maestro, Ignacio
A planar waveguide consisting of a coverslip for a microscope glass slide was deposited in one of its two faces with two materials: silver and indium tin oxide (ITO). The incidence of light by the edge of the coverslip permitted the generation of both surface plasmon and lossy mode resonances (SPRs and LMRs) in the same transmission spectrum with a single optical source and detector. This proves the ability of this optical platform to be used as a benchmark for comparing different optical phenomena generated by both metal and dielectric materials, which can be used to progress in the assessment of different sensing technologies. Here the SPR and the LMR were compared in terms of sensitivity to refractive index and figure of merit (FoM), at the same time it was demonstrated that both resonances can operate independently when silver and ITO coated regions are surrounded by different refractive index liquids. The results were supported with numerical results that confirm the experimental ones., The authors would like to acknowledge the partial support to the Agencia Estatal de Investigacion (AEI) PID2019-106070RB-I00 and PID2019-106231RB-I00 research funds, and the predoctoral research grants of the Public University of Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

From fundamental materials chemistry to sensing applications: unravelling the water adsorption mechanism of a luminescent optical fibre sensor membrane

  • Cruz Quesada, Guillermo
  • Rosales Reina, María Beatriz
  • López Torres, Diego
  • Reinoso, Santiago
  • López Ramón, María Victoria
  • Arzamendi Manterola, Gurutze
  • Elosúa Aguado, César
  • Espinal Viguri, Maialen
  • Garrido Segovia, Julián José
This work provides insight into the correlation between the luminescent response of a water-vapour optical fibre sensor and the textural properties of its lanthanide-doped silica coating. To this end, a library of 16 silica xerogels derived from combinations between 2 lanthanide dopants (EuIII, TbIII) and 8 antenna ligands was synthesised and characterised by photoluminescence spectroscopy and N2 and CO2 adsorption-desorption isotherms, among others. Based on the best luminescent response and most-suited porous texture, the material doped with TbIII and 2,2′-(4-(2-Ethoxyethoxy)pyridine-2,6-diyl)bis(4,5-dihydrooxazole) was selected to construct the probe. A film of this material was affixed to a commercial silica fibre by dip-coating and the resulting sensor was tested in a climatic chamber with relative humidity ranging from 20 to 90% to obtain normalised time-response and calibration curves at three temperatures. The response was linear up to certain water-vapour concentrations, beyond which abruptly changed to polynomial, acting against the sensor resolution. The adsorption mechanism was elucidated by comparing the isosteric enthalpies of adsorption calculated from the sensor calibration curves to those determined from the monolith water-vapour isotherms, revealing that capillary condensation in the membrane mesopores was the key phenomenon leading to the response deviating from linearity., Spanish Ministerio de Ciencia e Innovación (MICINN) and Agencia Estatal de Investigación (AEI): grant numbers PID2020-113558RB-C42 and PID2019-106070RB-I00. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Wavelength and intensity based lossy mode resonance breathing sensor

  • Bohórquez Navarro, Dina Luz
  • Del Villar, Ignacio
  • Corres Sanz, Jesús María
  • Matías Maestro, Ignacio
Copper oxide (CuO) allows the generation of lossy mode resonance (LMR) in a wide wavelength range of the optical spectrum, both in the visible and the near-infrared (NIR). For this, it is necessary to use a configuration based on the lateral incidence of light on the edge of a planar waveguide structure. On the other hand, the use of additional coatings of tin oxide (SnO2) and agarose allows an increase in the sensitivity of the sensor, in response to the breathing monitoring. The sensors were characterized, both in intensity and wavelength. In both cases their behavior depends on the position of the LMR in the optical spectrum. Therefore, it is convenient to extract the design rules that allow an optimal behavior of the sensor. In this sense, sensors located in the NIR presented a better behavior in terms of sensitivity and quality of the signal. In addition, the devices were tested in different conditions: repetitive tests at different distances, oral and nasal breathing, and breathing after doing physical exercise., The authors would to acknowledge the partial support to the Agencia Estatal de Investigacion (AEI) from the Spanish Ministry of Economy and Competitiveness (PID2019-106231RB-I00 and PID2019-106070RB-I00 research funds) and the predoctoral research grant of the Public University of Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Electrochemical lossy mode resonance for the detection of manganese ions

  • Domínguez Rodríguez, Ismel
  • Corres Sanz, Jesús María
  • Del Villar, Ignacio
  • Mozo, Juan D.
  • Simerova, Radka
  • Sezemsky, Petr
  • Stranak, Vitezslav
  • Smietana, Mateusz
  • Matías Maestro, Ignacio
In this work we propose electrochemical lossy mode resonance (eLMR) as a powerful method for the detection of manganese (Mn) ions. The sensor is based on a simple planar waveguide (sodasingle bondlime glass coverslip) coated with a thin layer of indium tin oxide (ITO) to obtain an optical resonance effect. Simultaneously, the ITO layer served as the working electrode in the cathodic stripping voltammetry (CSV) of Mn. The eLMR sensor is capable of simultaneously performing electrochemical (EC) and optical measurements, specifically lossy mode resonance (LMR), to monitor the growth of the adsorbed Mn layer on the ITO electrode and the electrochemically modulated diffusion layer. For Mn2+ ions, a limit of detection (LoD) of 1.26 ppb has been demonstrated using the EC method, whereas the optical method exhibited a LoD of 67.76 ppb. The results obtained indicate significant potential for application in molecular electrochemistry and studies focused on electrified interfaces., This work was supported in part by the Agencia Estatal de Investigación (AEI) from the Spanish Ministry of Economy and Competitiveness (PID2019-106070RB-I00 and PID2022-137437OB-I00 research funds), by the Government of Navarre through its projects with references: and PC058-059 EleSpray and 0011-1365-2022-000241, and by the pre-doctoral research grant of the Public University of Navarra. The authors also acknowledge financial support received from the National Centre for Research and Development, Poland, grant No. TECHMATSTRATEG- III/0042/2019, as well as the Czech Science Foundation Agency through the project 21-05030K and the National Science Centre (NCN), Poland, as part of the 2020/02/Y/ST8/00030 project. Open access funding provided by Universidad Pública de Navarra.