Pasar al contenido principal

PLANTAS FOTOVOLTAICAS CON MODULOS BIFACIALES: ANALISIS, CARACTERIZACION Y OPTIMIZADO

PID2019-110816RB-C21

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD PUBLICA DE NAVARRA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

On the calculation of the optimum position of a horizontal single axis tracker under any sky conditions

  • Arrubla Irigoyen, Mikel
  • García Solano, Miguel
  • Marroyo Palomo, Luis
  • García Colomo, Iñigo
Many current PV installations incorporate solar tracking systems that always seek to orient the surface of the modules as perpendicular as possible to the Sun (astronomical tracking). This position of the trackers is easy to calculate and allows to maximize the beam irradiance captured, which is by far the largest component of irradiance on a sunny day. However, under other sky conditions, this positioning strategy does not necessarily maximize the total irradiance captured by the PV modules and other tracking strategies could increase the PV generation at no additional cost. The proper design and evaluation of such strategies requires to know the optimum position of a PV tracker as a function of the sky conditions, but the analytical calculation of that position is still an open question in the state of the art. In this paper, two analytical expressions have been developed to calculate the optimal position of a horizontal single-axis tracker under any sky condition. One of them uses a new isotropic-diffuse transposition factor developed in this paper to consider the influence of adjacent trackers in the diffuse irradiance received by modules. All the expressions proposed here have been experimentally validated in a PV installation specifically designed to measure the optimal position of a horizontal single-axis tracker. The experimental results not only allow to determine which of the proposed expressions better approaches the measured optimal position, but also to properly compare their impact on the total irradiation received by the PV modules., This work has been partially supported by the Spanish State Research Agency (AEI), Spain and the European Regional Development Fund (ERDF), European Union, under grant PID2019-110816RB-C21, and also by the Government of Navarra, Spain, which financed the hiring of the PhD student within the framework of the call for grants “Industrial Doctorates 2022”.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Long-term degradation rate of crystalline silicon PV modules at commercial PV plants: an 82-MWp assessment over 10 years

  • Pascual Miqueleiz, Julio María
  • Martínez Moreno, Francisco
  • García Solano, Miguel
  • Marcos Álvarez, Javier
  • Marroyo Palomo, Luis
  • Lorenzo Pigueiras, Eduardo
Due to high competitiveness in the PV sector, despite the low degradation rate of crystalline silicon PV modules (below 0.5%/year), it is still important for utilities to know its actual value due to its impact on energy yield and hence, profitability, over the lifetime of a PV plant. However, uncertainties related to both the influence of downtime periods due to problems that may appear under normal operation of a commercial PV plant and to the measurement of degradation rates at PV plant level make this a challenging task. In order to obtain a significant value, in this paper, three measuring methods with different uncertainty sources are used for 82 MWp of PV modules on different locations in Spain and Portugal over 10 years. According to the different methods used and PV plants analyzed, excluding PV plants with problems, a range of degradation rates between 0.01 and 0.47%/year has been found. The overall average value observed is 0.27%/year. The findings of this work have also revealed the great importance of good operation and maintenance practices in order to keep overall low degradation rates., This work has been supported by the Spanish State Research Agency (Agencia Estatal de Investigación, AEI) under grant PID2019‐110816RB‐C21/AEI/10.13039/501100011033.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Energy management for an electro-thermal renewable based residential microgrid with energy balance forecasting and demand side management

  • Pascual Miqueleiz, Julio María
  • Arcos Avilés, Diego
  • Ursúa Rubio, Alfredo
  • Sanchis Gúrpide, Pablo
  • Marroyo Palomo, Luis
This paper proposes an energy management strategy for a residential microgrid comprising photovoltaic (PV) panels, a small wind turbine and solar thermal collectors. The microgrid can control the power exchanged with the grid thanks to a battery and a controllable electric water heater, which provide two degrees of freedom to the control strategy. As input data, the proposed control strategy uses the battery state of charge (SOC), the temperature of the hot water tank, the power of each microgrid element as well as the demand and renewable generation forecasts. By using forecasted data and by controlling the electric water heater, the strategy is able to achieve a better grid power profile while using a smaller battery than previous works, hence reducing the overall cost of the system. The strategy is tested by means of simulation with real data for one year and it is also experimentally validated in the microgrid built at the Renewable Energy Laboratory at the UPNA., The authors would like to acknowledge that this work has been partially funded under grants PID2019-110816RB-C21 and PID2019–111262RB–I00 by the Spanish State Research Agency (AEI/ 10.13039/501100011033). And also by VLIR-UOS and the Belgian Development Cooperation (DGD) under the project EC2020SIN322A101 (2020-EXT-007).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

A PV ramp-rate control strategy to extend battery lifespan using forecasting

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This study analyses and presents a new ramp-rate control algorithm for smoothing PV power fluctuations, designed to address three fundamental objectives: to reduce battery cycling, to meet minimum storage requirements and to be able to operate, without ramp-rate violations, with real publicly-available forecasting. The algorithm was compared to three benchmark methods and, as a performance limit, also to a hypothetical perfect prediction. Different performance variables were analyzed for all the strategies within a restricted ramp-rate constraint (2%/min): minimum storage requirement, battery power distributions, throughput energy, state of charge (SOC) distributions, degradation (calendar and cycling), expected battery lifespan and levelized cost of energy (LCOE). The proposal proves to be the most cost-effective smoothing technique and the simulation results show that its performance is comparable to the obtained with the use of an assumed perfect prediction., Support of the Spanish State Research Agency (AEI) under grants PID2019111262RB-I00 and PID2019-110816RB-C21. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

An energy management system design using fuzzy logic control: smoothing the grid power profile of a residential electro-thermal microgrid

  • Arcos Avilés, Diego
  • Pascual Miqueleiz, Julio María
  • Guinjoan Gispert, Francesc
  • Marroyo Palomo, Luis
  • García Gutiérrez, Gabriel
  • Gordillo, Rodolfo
  • Llanos, Jacqueline
  • Sanchis Gúrpide, Pablo
  • Motoasca, Emilia
This work deals with the design of a Fuzzy Logic Control (FLC) based Energy Management System (EMS) for smoothing the grid power prole of a grid-connected electro-thermal microgrid. The case study aims to design an Energy Management System (EMS) to reduce the impact on the grid power when renewable energy sources are incorporated to pre-existing grid-connected household appliances. The scenario considers a residential microgrid comprising photovoltaic and wind generators, at-plate collectors, electric and thermal loads and electrical and thermal energy storage systems and assumes that neither renewable generation nor the electrical and thermal load demands are controllable. The EMS is built through two low-complexity FLC blocks of only 25 rules each. The first one is in charge of smoothing the power prfile exchanged with the grid, whereas the second FLC block drives the power of the Electrical Water Heater (EWH). The EMS uses the forecast of the electrical and thermal power balance between generation and consumption to predict the microgrid behavior, for each 15-minute interval, over the next 12 hours. Simulations results, using real one-year measured data show that the proposed EMS design achieves 11.4% reduction of the maximum power absorbed from the grid and an outstanding reduction of the grid power profile ramp-rates when compared with other state-of-the-art studies., This work was supported in part by the projects 2019-PIC-003-CTE and 2020-EXT-007 from the Research Group of Propagation, Electronic Control, and Networking (PROCONET) of Universidad de las Fuerzas Armadas ESPE, in part by the Belgian Development Cooperation (DGD) and the VLIR-UOS under the project EC2020SIN322A101, in part by the Spanish Ministry of Industry and Competitiveness under Grant DPI2017-85404 and Grant PID2019-111443RB-100, and in part by the Spanish State Research Agency (AEI/10.13039/501100011033) under Grant PID2019-110816RB-C21 and Grant PID2019-111262RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

In-field energy performance of solar PV module made of UMG silicon

  • Guerra Menjívar, Moisés Roberto
  • Parra Laita, Íñigo de la
  • García Solano, Miguel
  • Pascual Miqueleiz, Julio María
Upgraded metallurgical grade silicon (UMG-Si) PV modules have failed to make their space in the PV market, which was partly to the uncertainty on their in-field performance that brings the wide disparity of results published over the years. The most-recently developed UMG-Si PV modules have demonstrated similar initial degradation and efficiencies under standard test conditions (STC) to those obtained with conventional solar grade silicon (SoG-Si). Nevertheless, their performance under operating conditions other than STC and its impact on the energy production are key aspects that have not yet been properly characterized in the literature. This article analyzes the in-field performance of a PV generator comprised of recently developed UMG-Si modules. This performance was compared to that of another PV generator comprising standard polysilicon modules. The cells and modules of both types of generators were made by the same manufacturer in the same period and on the same production lines, which guarantees that performance differences encountered are exclusively due to the silicon employed. Contrary to the previous experience, this article reveals that UMG-Si modules do not necessarily present a better temperature performance than today's conventional modules. The analyzed UMG-Si modules presented 1.6% less efficiency under low irradiance conditions, but this different irradiance performance led to an insignificant difference (less than 0.5%) in their energy production. No significant degradation was measured in both UMG-Si and SoG-Si modules during the two-year analyzed period, being the final energy performance of both types of modules essentially the same. These results can be considered as highly representative of the current state-of-the-art of UMG-Si technology., This work was supported by the Spanish State Research Agency and the ERDFEU under Grant PID2019-110816RB-C21 and Grant PID2019-111262RB-I00.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Control method to coordinate inverters and batteries for power ramp-rate control in large PV plants: minimizing energy losses and battery charging stress

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This work presents a novel control method for multi-megawatt photovoltaic (PV) plants that is able to regulate each plant inverter and the battery system to mitigate PV power fluctuations. The proposed control method makes it possible to implement different PV ramp-rate control strategies based on the use of batteries and the limitation of inverters during positive fluctuations, which have been conceptually proposed in the specialized bibliography, but have omitted how to perform the coordination between PV generators. The dynamic model and the tuning of the control parameters are presented and the method is used to correctly implement different inverter-limitation strategies using 5-second data from a real 45 MWp PV plant. Furthermore, a new control strategy is proposed. This strategy reduces curtailment losses to negligible values and takes into account and addresses the intrinsic asymmetry in the battery charging and discharging capability, an issue that has been overlooked in the specialized bibliography. The results show that the proposed control method can effectively control each of the multiple inverters in order to obtain the desired PV plant operation to regulate the battery charging power, even during highly fluctuating scenarios., The authors to acknowledge the support of the Spanish State Research Agency (AEI) under grants PID2019111262RB-I00 and PID2019-110816RB-C21. Alejandro González-Moreno would like to thank the Universidad Pública de Navarra (UPNA) for its financial support. Open access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Influence of control in cycling degradation when batteries perform PV ramp-rate control

  • González Moreno, Alejandro
  • Marcos Álvarez, Javier
  • Parra Laita, Íñigo de la
  • Marroyo Palomo, Luis
This work studies the importance of the correct selection of control parameters in order to avoid unnecessary cycling in batteries when they perform PV smoothing. The classic ramp-rate control method (CRRC) is studied as smoothing technique and the key role of the state of charge (SOC) control is analyzed for a real 38.5 MW PV plant, particularly the influence of proportional gain (K). Depending on K, battery cycling degradation (CyD), power requirements, SOC limits and throughout energy performance were discussed. According to the results, the correct tuning could prolong battery lifespan by reducing cycling degradation up to 80% (depending on the fluctuation restrictions and K) and avoiding unnecessary energy losses, power requirements and undesirable SOC operation levels. Finally, a simple general rule is proposed to set K value when CRRC is used and its applicability is tested by simulating two additional PV plants with rated power of 1.1 and 75.6 MW., This work was supported in part by the Spanish State Research Agency (AEI) under grants PID2019-111262RBI00 and PID2019-110816RB-C21-I00 as well as the Doctoral Scholarships funded by Public University of Navarra (UPNA).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Performance enhancement of bifacial PV modules on horizontal single-axis trackers in desert environments

  • Parra Laita, Íñigo de la
  • García Solano, Miguel
  • Marcos Álvarez, Javier
  • Marroyo Palomo, Luis
The adoption of bifacial photovoltaic (PV) modules has grown significantly due to their potential for higher energy yield. However, their real-world performance under outdoor conditions remains insufficiently explored. This study analyzes the energy gains of bifacial PV modules in a horizontally tracked power plant in the Atacama Desert, Chile, comparing a conventional single-axis tracker with an optimized tracker designed for bifacial performance. Results show that bifacial modules on conventional trackers achieve ∼5% higher energy production, while those on optimized trackers reach up to 6.1%, emphasizing the role of tracker design in maximizing bifacial PV efficiency., This work was supported in part by the Spanish State Research Agency and ERDF-EU under Grant PID2019-110816RB-C21 and Grant PID2022-142179OB-I00, in part by the Public University of Navarre under Grant PJUPNA2023-11389, and Open Access funding provided by Universidad Pública de Navarra.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Analysis of polyamide and fluoropolymer backsheets: Degradation and insulation failure in field-aged photovoltaic modules

  • Pascual Miqueleiz, Julio María
  • García Solano, Miguel
  • Marcos Álvarez, Javier
  • Marroyo Palomo, Luis
Durability of photovoltaic (PV) modules is of great concern not only from the point of view of cost-effectiveness but also from the point of view of safety and sustainability. The backsheet of a PV module is one of the most critical parts of the PV module from the point of view of protection and also one of the most important sources of PV modules' failure; hence, it is of great importance to understand its different forms of failure. In this paper we analyze the case of an 8-MW PV plant, which had suffered a rapid degradation of their PV modules' backsheets. The case is especially relevant as all the PV modules are from the same model and manufacturer but with different backsheet materials (polyamide and fluoropolymer) and different times of exposure: on one hand, all PV modules originally installed in the plant (i.e., 6 years under operation when tested), and also, extra modules that had been stored indoors for replacement and had been mounted in the plant for less than 1 year when tested, serving as reference modules. In this paper we present the signs of degradation of these PV modules after different times of exposure under real operation using different on-field and laboratory tests. We propose different techniques for rapid diagnosis of backsheet degradation so that the problem can be detected at a very early stage, before it results in major energy losses or in safety issues., This work has been supported by the Spanish State Research Agency(AEI) and ERDF-UE under grant PID2019-110816RB-C21. We would like to thank the Universidad Pública de Navarra for funding the Open Access fee.
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publicación Artículo científico (JournalArticle)

Determining the optimal size of energy storage systems for wind farm ramp-rate control

  • Parra Laita, Íñigo de la
  • Marcos Álvarez, Javier
  • Pascual Miqueleiz, Julio María
  • García Solano, Miguel
  • Marroyo Palomo, Luis
Short-term power fluctuations from grid-connected wind farms pose challenges to grid reliability and stability, particularly in terms of ramp-rate compliance. To address these issues, new regulations require integrating energy storage systems with renewable generators. This paper presents a method for determining the optimal power and energy capacity of storage systems specifically designed to ensure wind farm compliance with ramp-rate constraints. The proposed approach is validated using three strategies originally developed for photovoltaic applications, demonstrating their effectiveness when adapted to wind energy. Validation is based on high-resolution real-world data recorded at 1-second intervals and averaged over 5 s, covering one year at a wind farm in northern Spain with five 3 MW wind turbines. Additionally, the annual cycling degradation of the storage system is analyzed. The effectiveness of the ramp-rate control strategies is further validated through experimental testing on a real system comprising two lithium-ion batteries: a 1 MW/0.39 MWh power battery with a fast response and a 0.7 MW/0.7 MWh energy battery with a slower response but greater autonomy. These batteries are connected to a 3 MW wind turbine, where a commercially available power converter is adapted for use as a battery charger., This work has been supported by the Spanish State Research Agency (AEI) and ERDF-EU under grants PID2019-110816RB-C21 , TED2021-132457B-I00 and PID2022-142179OB-I00 .