Pasar al contenido principal

DESARROLLO DE NUEVAS TECNICAS ULTRASONICAS CUANTITATIVAS PARA IMAGEN MEDICA BASADAS EN ALGORITMOS EN EL DOMINIO DE LA FRECUENCIA .

PID2019-111392RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of the Cell Concentration in Suspensions of Human Leukocytes by Ultrasound Imaging: The Influence of Size Dispersion and Cell Type

  • Elvira Segura, Luis
  • Fernández, Alba
  • León, Lucía
  • Ibáñez Rodríguez, Alberto
  • Parrilla Romero, Montserrat
  • Martínez-Graullera, Óscar
  • Jiménez, Javier
13 páginas, 5 figuras, 1 tabla, This work focuses on the use of ultrasound imaging to evaluate the cell concentration of dilute leukocyte suspensions in the range of 10–3000 cells/µL. First, numerical simulations were used to study the influence of the size dispersion and the leukocyte type on the performance of the concentration estimation algorithms, which were developed in previous works assuming single-sized scatterers. From this analysis, corrections to the mentioned algorithms were proposed and then the performance of these corrections was evaluated from experiments. For this, ultrasound images were captured from suspensions of lymphocytes, granulocytes, and their mixtures. These images were obtained using a 20 MHz single-channel scanning system. Results confirmed that concentration estimates provided by conventional algorithms were affected by the size dispersion of cells, leading to a remarkable underestimation of results. The proposed correction to compensate for cell size dispersion obtained from simulations improved the concentration estimation of these algorithms, for the cell suspensions tested, approaching the results to the reference optical characterization. Moreover, it was shown that these models provided a total leukocyte concentration from the ultrasound images which was independent of the relative populations of different white blood cell types., This work was supported by the project PID2019-111392RB-I00 (Spanish Ministry of Science and Innovation), by the contract GARJUV_CAM_18_00217 from the Youth Employment Program (Madrid Department of Education and Research) and co-financed by the European Social Fund (ESF), as well as by the project RIS 3 2020/NEOSONICS with code STARTUP-2020\L2-571, cofounded by Madrid Community and the European Regional Development’s Fund (FEDER).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tissue Characterization by Ultrasound: Linking Envelope Statistics with Spectral Analysis for Simultaneous Attenuation Coefficient and Scatterer Clustering Quantification

  • Elvira Segura, Luis
  • León, Carla de
  • Durán Gómez, Carmen
  • Ibáñez Rodríguez, Alberto
  • Parrilla Romero, Montserrat
  • Martínez-Graullera, Óscar
This paper proposes the use of quantitative methods for the characterization of tissues by linking, into a single approach, ideas coming from the spectral analysis methods commonly used to determine the attenuation coefficient with the envelope statistics formulation. Initially, the Homodyned K-distribution model used to fit data obtained from ultrasound signal envelopes was reviewed, and the necessary equations to further derive the attenuation coefficient from this model were developed. To test and discuss the performance of these methods, experimental work was conducted in phantoms. To this end, a series of tissue-mimicking materials composed of poly-vinyl alcohol (PVA) loaded with different particles (aluminium, alumina, cellulose) at varying concentrations were manufactured. A single-channel scanning system was employed to analyse these samples. It was verified that quantitative images obtained from the attenuation coefficient and from the scatterer clustering μ parameter (associated with scatterer concentration) effectively discriminate materials exhibiting similar echo envelope patterns, enhancing the information obtained in comparison with the conventional analysis based on B-scans. Additionally, the implementation of quantitative bi-parametric imaging mappings based on both the μ parameter and the attenuation coefficient, as a means to rapidly visualize results and identify areas characterized by specific acoustic features, was also proposed., This work was supported by the projects PID2019-111392RB-I00 and PID2022-138013OB-I00 from the Spanish Ministry of Science and Innovation. This work has been funded with EUR 1.026 million by the Comunidad de Madrid through the LUNABRAIN-CM R&D activities program (TEC-2024/TEC-43), granted by Order 5696/2024., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Design of Ultrasonic Synthetic Aperture Imaging Systems Based on a Non-Grid 2D Sparse Array

  • de Souza, Júlio Cesar Eduardo
  • Parrilla Romero, Montserrat
  • Higuti, Ricardo Tokio
  • Martínez Graullera, Óscar
This article belongs to the Special Issue Ultrasonic Imaging and Sensors., This work provides a guide to design ultrasonic synthetic aperture systems for non-grid two-dimensional sparse arrays such as spirals or annular segmented arrays. It presents an algorithm that identifies which elements have a more significant impact on the beampattern characteristics and uses this information to reduce the number of signals, the number of emitters and the number of parallel receiver channels involved in the beamforming process. Consequently, we can optimise the 3D synthetic aperture ultrasonic imaging system for a specific sparse array, reducing the computational cost, the hardware requirements and the system complexity. Simulations using a Fermat spiral array and experimental data based on an annular segmented array with 64 elements are used to assess this algorithm., The Spanish Government supported this research under grant number DPI 2016-80239-R (AEI/FEDER, UE) and PID 2019-111392RB-I00. This study was financed in part by the Coordination of Superior Level Staff Improvement—Brazil (CAPES)—Finance Code 001 and the Brazilian National Council for Scientific and Technological Development (CNPq)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Design of 2D Planar Sparse Binned Arrays Based on the Coarray Analysis

  • Martínez-Graullera, Óscar
  • de Souza, Júlio Cesar Eduardo
  • Parrilla Romero, Montserrat
  • Higuti, Ricardo Tokio
This article belongs to the Special Issue Ultrasonic Imaging and Sensors., The analysis of the beampattern is the base of sparse arrays design process. However, in the case of bidimensional arrays, this analysis has a high computational cost, turning the design process into a long and complex task. If the imaging system development is considered a holistic process, the aperture is a sampling grid that must be considered in the spatial domain through the coarray structure. Here, we propose to guide the aperture design process using statistical parameters of the distribution of the weights in the coarray. We have studied three designs of sparse matrix binned arrays with different sparseness degrees. Our results prove that there is a relationship between these parameters and the beampattern, which is valuable and improves the array design process. The proposed methodology reduces the computational cost up to 58 times with respect to the conventional fitness function based on the beampattern analysis., The Spanish Govermment supported this research under grant number DPI 2016-80239-R (AEI/FEDER, UE) and, PID 2019-111392RB-I00. This study was financed in part by the Coordination of Superior Level Staff Improvement—Brazil (CAPES)—Finance Code 001 and the Brazilian National Council for Scientific and Technological Development (CNPq)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Estimation of the concentration of particles in suspension based on envelope statistics of ultrasound backscattering

  • Fernández, Alba
  • Ibáñez Rodríguez, Alberto
  • Parrilla Romero, Montserrat
  • Elvira Segura, Luis
  • Bassat, Quique
  • Jiménez, Javier
13 páginas, 17 figuras, 2 tablas, This work deals with the development of a methodology to evaluate the concentration in cell or particle sus- pensions from ultrasound images. The novelty of the method is based on two goals: first, it should be valid when the energy reaching the scatterers is unknown and cannot be measured or calibrated. In addition, it should be robust against echo overlap which may occur due to high scatterer concentration. Both characteristics are especially valuable in quantitative ultrasound analysis in the clinical context. In this regard, the present work considers the ability of envelope statistics models to characterize ultrasound images. Envelope statistical analysis are based on the examination of the physical properties of a medium through the study of the statistical dis- tribution of the backscattered signal envelop. A review of the statistical distributions typically used to charac- terize scattering mediums was conducted. The main parameters of the distribution were estimated from simulations of signals backscattered by particle suspensions. Then, the ability of these parameters to characterize the suspension concentration was analyzed and the μ parameter from the Homodyned-K distribution resulted as the most suitable parameter for the task. Simulations were also used to study the impact of noise, signal amplitude variability and dispersion of particle sizes on the estimation method. The efficiency of the algorithm on experimental measurements was also evaluated. To this end, two sets of ultrasound images were obtained from suspensions of 7 μm and 12 μm polystyrene particles in water, using a 20 MHz focused transducer. The methodology proved to be efficient to quantify the concentration of particle suspensions in the range between 5 and 3000 particles/μl, achieving similar results for both particle sizes and for different signal-to-noise ratios., This work was supported by the Instituto de Salud Carlos III, projects PI16/00738 and PI16/01822, and co-financed by FEDER resources, by the project PID2019-111392RB-I00 (Spanish Ministry of Science and Innovation) and by the contract GARJUV_CAM_18_00217 from the Youth Employment Program (Madrid Department of Education and Research), co-financed by the European Social Fund (ESF). ISGlobal also receives support from the Spanish Ministry of Science and Innovation through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S), and support from the Generalitat de Catalunya through the CERCA Program. CISM is supported by the Government of Mozambique and the Spanish Agency for International Development (AECID), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A New Methodology for the Assessment of Very Low Concentrations of Cells in Serous Body Fluids Based on the Count of Ultrasound Echoes Backscattered From Cells

  • Elvira Segura, Luis
  • Ibáñez Rodríguez, Alberto
  • Fernández, Alba
  • Durán Gómez, Carmen
  • Parrilla Romero, Montserrat
  • Pose Díez de la Lastra, Alicia
  • Bassat, Quique
  • Jiménez, Javier
13 páginas, 10 figuras, Amethodology for the assessmentof cell concentration, in the range 5–100 cells/μL, suitable for in vivo analysis of serous body fluids is presented in this work. This methodology is based on the quantitative analysis of ultrasound images obtained fromcell suspensionsand considers applicability criteria, such as short analysis times, moderate frequency, and absolute concentration estimation, all necessary to deal with the variability of tissues among different patients. Numerical simulations provided the framework to analyze the impact of echo overlapping and the polydispersion of scatterer sizes on the cell concentration estimation. The cell concentration range that can be analyzed as a function of the transducer and emitted waveformused was also discussed. Experimentswere conducted to evaluate the performance of the method using 7-μmand 12-μmpolystyreneparticles inwater suspensions in the 5–100 particles/μL range. A single scanning focused transducer working at a central frequency of 20 MHz was used to obtain ultrasound images. The method proposed to estimate the concentration proved to be robust for different particle sizes and variations of gain acquisition settings. The effect of tissues placed in the ultrasound path between the probe and the sample was also investigated using 3-mm-thick tissuemimics. Under this situation, the algorithm was robust for the concentration analysis of 12 μm particle suspensions, yet significant deviations were obtained for the smallest particles., This work was supported in part by the Instituto de Salud Carlos III under Project PI16/00738 and PI16/01822, in part by FEDER (European Regional Development Fund) resources, and in part by the Spanish Ministry of Science and Innovation under Project PID2019-111392RB-I00. The work of Alba Fernández was supported in part by the Comunidad de Madrid and Alicia Pose through the JAEINTRO Programme under Contract PEJD-2018-PRE/IND-9090 and in part by the Consejo Superior de Investigaciones Científicas (CSIC) under Grant JAEINT_18_01152. The work of Quique Bassat was supported in part by the Spanish Ministry of Science and Innovation through the Centro de Excelencia Severo Ochoa 2019-2023 Program under Grant CEX2018-000806-S, in part by the Generalitat de Catalunya through the CERCA Program, in part by the Government of Mozambique, and in part by the Spanish Agency for International Development (AECID)., Peer reviewed