WEARABLES Y MOBILIARIO INTELIGENTE
PID2024-158986OB-C21
•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para la Investigación y el Desarrollo Experimental
Subprograma Subprograma Estatal de Generación de Conocimiento Científico-Técnico y Desarrollo Experimental
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2024
Unidad de gestión Plan Estatal de Investigación Científica y Técnica y de Innovación 2024-2027
Centro beneficiario UNIVERSIDAD DE MALAGA
Identificador persistente http://dx.doi.org/10.13039/501100011033
Resultados relacionados
Resultados totales (Incluyendo duplicados): 1Encontrada(s) 1 página(s)
Artículo científico (JournalArticle). 2025
Characterization and Comparison of Piezoresistive Materials and Their Performance on Pressure-Sensitive Mats
Zaguán. Repositorio Digital de la Universidad de Zaragoza
- Martínez-Cesteros, Javier
- Domínguez-Gimeno, Sergio
- Castellanos-Ramos, Julián
- Sánchez-Durán, José A.
- Medrano-Sánchez, Carlos
The response of three readily available low-cost piezoresistive materials (EeonTex, Ex-Static, and Velostat) and their performance on a specific application were studied in this work. First, a series of pressure cycles was applied with a pneumatic platform on piezoresistive sensors based on them. These experiments allowed quantifying several nonidealities: Variability, drift, creep, hysteresis, nonlinearity, and response time. An overview radar chart showed that hysteresis, variability, and response time were quantitatively more relevant and different between the materials. Then, pressure-sensitive mats (PSMs) were manufactured using each of those three materials. They were evaluated by measuring the center of pressure (CoP) in stability tests. A force platform (FP) served as a reference instrument. The best performance in this kind of experiment was obtained by the Velostat-based mat (trajectory distance of 0.021 versus 0.035 and 0.045 cm/sample for Ex-Static-based and EeonTexbased mats, respectively). This material also showed less response time (0.21 versus 0.42 and 0.50 s for Ex-Static and EeonTex, respectively) and hysteresis (0.11 versus 0.21 and 0.23 S/S for EeonTex and Ex-Static, respectively), although its variability was larger (0.137 versus 0.065 and 0.059 S/S for Ex-Static and EeonTex, respectively). These results indicate that response time and hysteresis have a major influence on the determination of the CoP. Further research should focus on compensating for these effects or finding sensor configurations that minimize them.