Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental study on the flexural behaviour of demountable steel-concrete composite beams at room temperature and under fire exposure

  • Paúl Sebastián
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Odenbreit, C.
[EN] In a context driven by the urgent need to promote sustainability and circularity in the construction sector, the use of demountable shear connectors in steel-concrete composite beams has a potential to make a significant contribution to reducing the carbon footprint, helping in the management of waste generated in the deconstruction stage through the "Design for Disassembly" concept. To ensure the viability of these shear connectors in practice, it is essential to understand their mechanical behaviour under various loading situations. This paper presents the outcomes of an experimental campaign comprising a series of beam tests conducted under both room and elevated temperature conditions. The results of the tests showed that, during a fire - provided that suitable protection is used for the steel beam -, the shear connectors retain their mechanical contribution and composite action between the steel beam and concrete slab is still active along fire exposure, thereby enhancing the flexural capacity of the beam. The findings from this investigation ensure the structural efficiency of demountable steel-concrete composite beams under both fire and ambient conditions, along with their alignment with the circular economy principles. This study sets the ground to facilitate the practical application of demountable steel-concrete composite beams in the construction sector., The authors gratefully acknowledge the Spanish "Agencia Estatal de Investigacion" for the help provided through the Project FIRSTIMB, carried out with a financial grant with reference TED2021-130580B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The authors are also very grateful to the "Association for the Promotion of Research and Technology of Fire Safety" (AFITI) for the facilities used to conduct the tests.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of combined high temperature and tensile load on the post-fire performance of high-strength steel

  • Lapuebla-Ferri, Andrés|||0000-0001-9667-236X
  • Pons Aliaga, David|||0000-0002-9034-9550
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Gardner, L.
[EN] An experimental campaign to evaluate the post-fire performance of grade S700 steel specimens subjected to a range of temperatures between 300 °C and 1000 °C and simultaneous tensile load, followed by natural cooling to room temperature, has been undertaken and is presented herein. The adopted test procedure provides a close representation of real fire and post-fire scenarios, since during a fire a structure is also subjected to a certain load level, an aspect that is usually neglected in research on this topic. The residual values of the key mechanical properties, including the yield strength, ultimate strength, Young¿s modulus, strain at fracture and ultimate strain, were computed. According to the experimental results, the post-fire response was found to be dependent on the production route of the tested material and, under some combinations of temperature and tensile load, the residual values of ultimate strain did not meet the Eurocode 3 ductility requirements, indicating that the residual ductility of a steel structure surviving a fire could be compromised. The present work provides valuable data for the safety assessment of structures after fires, and aids decision-making on whether to re-use, retrofit or demolish., The authors gratefully acknowledge the Spanish "Agencia Estatal de Investigacion" for the help provided through the Project FIRSTIMB, carried out with a financial grant with reference TED2021-130580B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The authors want also to thank Imperial College London for the provision of the high-strength cold-formed hollow sections.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Eurocode-based design method to evaluate the plastic bending moment capacity of demountable steel-concrete composite beams in the fire situation

  • Paúl Sebastián
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
  • Odenbreit, C.
[EN] In a context driven by the need to promote sustainability and circularity in construction, demountable steel-concrete composite beams offer a promising solution to reduce the carbon footprint by enabling the recovery and reuse of structural components during building deconstruction. However, ensuring their practical feasibility requires a thorough understanding of their mechanical behaviour at both room temperature and under fire conditions. This paper presents a novel methodology for the analytical evaluation of the plastic bending moment capacity of steel-concrete composite beams with demountable shear connectors under fire exposure, which is grounded on a thermo-mechanical finite element model presented in detail in this work. The numerical model accounted for the realistic characterization of the demountable shear connectors at elevated temperature, through the input of specific load-slip curves from push-out tests conducted in the framework of this research. Additionally, the numerical model was validated against the results of full-length beam tests, showing a very accurate representation of the flexural behaviour of the demountable steel-concrete composite beams at both ambient and fire conditions. The proposed calculation algorithm, using as a standpoint a previous room temperature design methodology, enables the calculation of the ultimate bending moment of the beams in the fire situation through a plastic design approach, extending the current applicability of the design rules in EN 1994-1-2 to cover demountable shear connections. To verify the developed analytical methodology, it was further tested to evaluate the flexural capacity of the studied steel-concrete composite beams at different standard fire periods, providing accurate and reliable predictions., The authors gratefully acknowledge the Spanish "Agencia Estatal de Investigacion" for the help provided through the Project FIRSTIMB, carried out with a financial grant with reference TED2021-130580B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". Funding for open access charge was provided by CRUE-Universitat Politecnica de Valencia, which is sincerely appreciated.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ambient-temperature and fire performance of steel-timber composite beams with demountable shear connectors

  • Paúl Sebastián
  • Lapuebla-Ferri, Andrés|||0000-0001-9667-236X
  • Espinós Capilla, Ana|||0000-0001-7335-4676
  • Romero, Manuel L.|||0000-0001-5247-4767
[EN] In the construction sector, current trans-national policies promote actions aimed to obtain environmental benefits throughout the whole life cycle of buildings, such as the use of more sustainable materials or the reduction of waste generation. In this context, the use of timber emerges as a technically viable alternative to replace other structural materials with a significantly higher embodied carbon and associated greenhouse gas emissions. When combined with steel in composite flooring systems, benefits at both structural and environmental level can be found. In the case of steel-timber composite (STC) beams, recent technological developments are intended to contribute to the transition toward a circular economy model in construction, for instance by facilitating the disassembly of the different parts by means of the use of demountable connection systems. Nevertheless, current knowledge on the mechanical performance of STC beams incorporating demountable shear connectors remains limited, both under service conditions and in accidental scenarios such as fire exposure. In the present work, an experimental research is presented, in which demountable STC beams were subjected to flexural loading at room temperature and under standard fire conditions until failure. The STC beams consisted of cross-laminated timber (CLT) slabs connected to a steel beam by means of two different types of demountable bolted shear connection systems. According to the results of this investigation, it is shown that this novel structural system performs appropriately under both loading scenarios. At room temperature, the STC beams showed high ductility and a significant load bearing capacity. In the fire situation, owing to the ad-hoc passive fire protection system proposed in this investigation, a fire resistance rating of about 120 min was achieved without losing the partial composite action between the timber slab and the steel beam. The outcomes of this work open new opportunities in fostering material efficient and environmentally friendly solutions of fire-resistant structural members., The authors gratefully acknowledge the Spanish Agencia Estatal de Investigacion for the help provided through the grants TED2021- 130580B-I00 and PID2024-161153OB-I00 along with the first author s pre-doctoral contract PREP2024-002384, funded by MICIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR, FEDER and FSE+ funds. The authors are also very grateful to the Association for the Promotion of Research and Technology of Fire Safety (AFITI) for the facilities used to conduct the tests. Similarly, the authors would like to thank Prof. Christoph Odenbreit from the University of Luxembourg for providing guidance during the development of this research project.