Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Repisalud
Publicación Artículo de revisión (ReviewArticle)

Diagnostic performance of dried blood spot hepatitis C virus core antigen testing for hepatitis C screening: A systematic review and meta-analysis.

  • Treviño-Nakoura, Ana
  • Sepulveda-Crespo, Daniel
  • Bellon, José M
  • Codina, Helena
  • Amigot-Sánchez, Rafael
  • Quero-Delgado, Marta
  • Ryan, Pablo
  • Martinez, Isidoro
  • Resino, Salvador
Dried blood spot (DBS) sampling is increasingly used for hepatitis C virus (HCV) screening. HCVcAg testing offers a faster and more streamlined approach to diagnosing HCV infection. We conducted a systematic review and meta-analysis to assess the diagnostic performance of the Abbott ARCHITECT HCV Ag assay for screening active HCV infection using DBS samples. Eight studies (n = 1229) were selected among all published studies available up to October 4, 2024, in different databases with a search strategy registered (PROSPERO: CRD42022363975). The gold standard method was the HCV PCR test. Data were analyzed using the MIDAS module in STATA with a random effects model. Combined diagnostic accuracy measures were as follows: sensitivity 85%, specificity 100%, positive likelihood ratio (PLR) 233.1, negative likelihood ratio (NLR) 0.15, and summary receiver operating characteristic (SROC) 0.99. Likelihood ratios and Fagan's nomogram suggested that the HCVcAg assay with DBS samples can confirm or rule out active HCV infection with over 92% accuracy in high-prevalence settings (≥5%). However, in low-prevalence settings (≤1%), a confirmatory test must be required for positive results. The ability of the test to identify people without HCV infection was high regardless of HCV prevalence, with an error rate of less than 3%. This meta-analysis is subject to limitations, particularly due to the number of included studies and significant heterogeneity among them. HCV screening using the Abbott ARCHITECT HCV Ag assay with DBS samples showed excellent diagnostic performance, but its external validity may be limited when HCV prevalence is low (≤1%).
Repisalud
Publicación Artículo de revisión (ReviewArticle)

Advances in Nanotechnology-Enabled Optical Biosensors for Dengue Virus Detection: A Systematic Review.

  • Quero-Delgado, Marta
  • Codina Márquez, Helena
  • Gómez, Rafael
  • Terán, Francisco José
  • Muñoz-Fernández, M A
  • Jiménez, José Luis
  • Resino, Salvador
  • Sepulveda-Crespo, Daniel
  • Martinez, Isidoro
The dramatic surge in dengue cases in early 2024, endangering half the global population, urgently necessitates faster diagnostic methods. Nanotechnology-enabled optical biosensors offer a promising avenue, leveraging nanomaterial properties for highly sensitive detection of dengue virus (DENV), potentially surpassing conventional techniques in terms of simplicity, speed, and cost-effectiveness. This systematic review analyzes recent advancements in these biosensors for DENV diagnosis. Following PRISMA 2020 guidelines, we systematically searched PubMed, Embase, Scopus, Web of Science, and Cochrane Library databases (2010-June 1, 2025; OSF: https://osf.io/3gmey/). The methodological quality of the 98 included studies was assessed using a modified CASP checklist. Diverse nanotechnology-based optical biosensors were identified. SPR (36.7%) was the most common transducer, followed by fluorescence (24.5%), colorimetry (15.3%), and SERS (8.2%). Gold-based nanomaterials (35.7%) were most frequently employed, with silver nanomaterials (15.3%), quantum dots (15.3%), and graphene-based materials (15.3%) also showing promise. DENV NS1 protein was the primary target analyte (21.4%). Importantly, almost half of the studies (44.9%) used clinically relevant human samples. While many optical biosensors show promise, challenges hinder their demonstration of the true potential for point-of-care use in their current format; however, they offer high specificity and faster results, laying a strong foundation for cost-effective clinical diagnostics. Nanotechnology-driven optical biosensors offer a transformative approach for DENV detection. Advances in computational design and green synthesis of novel nanomaterials are key to addressing stability and field-deployment challenges. These innovations are crucial for developing robust, sensitive, and user-friendly tools to manage dengue and improve patient outcomes globally.
Dipòsit Digital de Documents de la UAB
Publicación Artículo de revisión (ReviewArticle)

Recommendations of the Spanish Antibiogram Committee (COESANT) for selecting antimicrobial agents and concentrations for in vitro susceptibility studies using automated systems, Recomendaciones del Comité Español del Antibiograma (COESANT) para la selección de antimicrobianos y sus concentraciones en el estudio in vitro de la sensibilidad con métodos automáticos

  • Cantón, Rafael|||0000-0003-1675-3173
  • Oliver, Antonio|||0000-0001-9327-1894
  • Alós, Juan Ignacio
  • Benito, Natividad|||0000-0001-6410-013X
  • Bou, German|||0000-0001-8837-0062
  • Campos, José
  • Calvo, Jorge
  • Canut-Blasco, Andrés
  • Castillo, Javier
  • Cercenado, Emilia|||0000-0002-5279-3773
  • Domínguez, Maria Ángeles
  • Fernández-Cuenca, Felipe
  • Guinea, Jesús
  • Larrosa, María Nieves|||0000-0001-8808-0233
  • Liñares, Josefina
  • López-Cerero, Lorena
  • López-Navas, Antonio
  • Marco, Francesc|||0000-0002-1863-6379
  • Mirelis, Beatriz
  • Moreno-Romo, Miguel Ángel
  • Morosini, María Isabel
  • Navarro Risueño, Ferran|||0000-0002-4302-2838
  • Oteo-Iglesias, Jesús|||0000-0003-3327-8263
  • Pascual Leone, Álvaro|||0000-0001-8975-0382
  • Pérez Trallero, Emilio
  • Pérez-Vázquez, María
  • Soriano Viladomiu, Alex|||0000-0002-9374-0811
  • Torres, Carmen
  • Vila Estapé, Jordi|||0000-0002-8025-3926
  • Martínez-Martínez, Luis
Automated antimicrobial susceptibility testing devices are widely implemented in clinical microbiology laboratories in Spain, mainly using EUCAST (European Committee on Antimicrobial Susceptibility Testing) breakpoints. In 2007, a group of experts published recommendations for including antimicrobial agents and selecting concentrations in these systems. Under the patronage of the Spanish Antibiogram Committee (Comité Español del Antibiograma, COESANT) and the Study Group on Mechanisms of Action and Resistance to Antimicrobial Agents (GEMARA) from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC), and aligned with the Spanish National Plan against Antimicrobial Resistance (PRAN), a group of experts have updated this document. The main modifications from the previous version comprise the inclusion of new antimicrobial agents, adaptation of the ranges of concentrations to cover the EUCAST breakpoints and epidemiological cut-off values (ECOFFs), and the inference of new resistance mechanisms. This proposal should be considered by different manufacturers and users when designing new panels or cards. In addition, recommendations for selective reporting are also included. With this approach, the implementation of EUCAST breakpoints will be easier, increasing the quality of antimicrobial susceptibility testing data and their microbiological interpretation. It will also benefit epidemiological surveillance studies as well as the clinical use of antimicrobials aligned with antimicrobial stewardship programs., Los sistemas automáticos utilizados en el estudio de la sensibilidad a los antimicrobianos están introducidos en la mayoría de los laboratorios de Microbiología Clínica en España, utilizando principalmente los puntos de corte del European Committee on Antimicrobial Susceptibility Testing (EUCAST). En 2007, un grupo de expertos publicó unas recomendaciones para incluir antimicrobianos y seleccionar concentraciones en estos sistemas. Bajo el auspicio del Comité Español del Antibiograma (COESANT) y del Grupo de Estudio de los Mecanismos de Acción y Resistencia a los Antimicrobianos (GEMARA) de la Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica (SEIMC) y alineado con el Plan Nacional frente a la Resistencia a los Antibióticos (PRAN), un grupo de expertos ha actualizado dicho documento. Las principales modificaciones realizadas sobre la versión anterior comprenden la inclusión de nuevos agentes antimicrobianos, la adaptación de los rangos de concentraciones para cubrir los puntos de corte clínicos y los puntos de corte epidemiológicos (ECOFF) definidos por el EUCAST, y para la inferencia de nuevos mecanismos de resistencia. Esta propuesta debería ser considerada por los diferentes fabricantes y los usuarios cuando se diseñen nuevos paneles o tarjetas. Además, se incluyen recomendaciones para realizar informes selectivos. Con este enfoque, la implementación de los puntos de corte del EUCAST será más fácil, aumentando la calidad de los datos del antibiograma y su interpretación microbiológica. También será de utilidad para los estudios de vigilancia epidemiológica, así como para el uso clínico de los antimicrobianos, de acuerdo con los programas de optimización de uso de antimicrobianos (PROA).