Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Deep Learning-based Approach for the Semantic Segmentation of Bright Retinal Damage

  • Silva, Cristiana
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Regular screening for the development of diabetic retinopathy is imperative for an early diagnosis and a timely treatment, thus preventing further progression of the disease. The conventional screening techniques based on manual observation by qualified physicians can be very time consuming and prone to error. In this paper, a novel automated screening model based on deep learning for the semantic segmentation of exudates in color fundus images is proposed with the implementation of an end-to-end convolutional neural network built upon UNet architecture. This encoder-decoder network is characterized by the combination of a contracting path and a symmetrical expansive path to obtain precise localization with the use of context information. The proposed method was validated on E-OPHTHA and DIARETDB1 public databases achieving promising results compared to current state-of-theart methods., This paper was supported by the European Union’s Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT2016-2017, 732613]. The work of Adri´an Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Towards Automatic Glaucoma Assessment: An Encoder-decoder CNN for Retinal Layer Segmentation in Rodent OCT images

  • del Amor, Rocío
  • Woldbye, David
  • Klemp, Kristian
  • Larsen, Michael
  • Morales, Sandra|||0000-0003-0763-1545
  • Colomer, Adrián|||0000-0002-7616-6029
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Optical coherence tomography (OCT) is an important imaging modality that is used frequently to monitor the state of retinal layers both in humans and animals. Automated OCT analysis in rodents is an important method to study the possible toxic effect of treatments before the test in humans. In this paper, an automatic method to detect the most significant retinal layers in rat OCT images is presented. This algorithm is based on an encoder-decoder fully convolutional network (FCN) architecture combined with a robust method of post-processing. After the validation, it was demonstrated that the proposed method outperforms the commercial Insight image segmentation software. We obtained results (averaged absolute distance error) in the test set for the training database of 2.52±0.80 µm. In the predictions done by the method, in a different database (only used for testing), we also achieve the promising results of 4.45 ± 3.02 µm., This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Retinal Image Synthesis for Glaucoma Assessment using DCGAN and VAE Models

  • Díaz-Pinto, Andrés Yesid
  • Xu, Yanwu
  • Frangi, Alejandro F.
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Morales, Sandra|||0000-0003-0763-1545
The performance of a Glaucoma assessment system is highly affected by the number of labelled images used during the training stage. However, labelled images are often scarce or costly to obtain. In this paper, we address the problem of synthesising retinal fundus images by training a Variational Autoencoder and an adversarial model on 2357 retinal images. The innovation of this approach is in synthesising retinal images without using previous vessel segmentation from a separate method, which makes this system completely independent. The obtained models are image synthesizers capable of generating any amount of cropped retinal images from a simple normal distribution. Furthermore, more images were used for training than any other work in the literature. Synthetic images were qualitatively evaluated by 10 clinical experts and their consistency were estimated by measuring the proportion of pixels corresponding to the anatomical structures around the optic disc. Moreover, we calculated the mean-squared error between the average 2D-histogram of synthetic and real images, obtaining a small difference of 3e-4. Further analysis of the latent space and cup size of the images was performed by measuring the Cup/Disc ratio of synthetic images using a state-of-the-art method. The results obtained from this analysis and the qualitative and quantitative evaluation demonstrate that the synthesised images are anatomically consistent and the system is a promising step towards a model capable of generating labelled images., We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research. This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Deep-Learning-based Classification of Rat OCT images After Intravitreal Injection of ET-1 for Glaucoma Understanding

  • Fuentes-Hurtado, Félix José
  • Fedulov, Vadim
  • Woldbye, David
  • Klemp, Kristian
  • Torm, Marie
  • Larsen, Michael
  • Morales, Sandra|||0000-0003-0763-1545
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Optical coherence tomography (OCT) is a useful technique to monitor retinal damage. We present an automatic method to accurately classify rodent OCT images in healthy and pathological (before and after 14 days of intravitreal injection of Endothelin-1, respectively) making use of the DenseNet-201 architecture fine-tuned and a customized top-model. We validated the performance of the method on 1912 OCT images yielding promising results ( AUC=0.99±0.01 in a P=15 leave-P-out cross-validation). Besides, we also compared the results of the fine-tuned network with those achieved training the network from scratch, obtaining some interesting insights. The presented method poses a step forward in understanding pathological rodent OCT retinal images, as at the moment there is no known discriminating characteristic which allows classifying this type of images accurately. The result of this work is a very accurate and robust automatic method to distinguish between healthy and a rodent model of glaucoma, which is the backbone of future works dealing with human OCT images., Animal experiment permission was granted by the Danish Animal Experimentation Council (license number: 2017-15-0201-01213). We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research. This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Comparison of Local Analysis Strategies for Exudate Detection in Fundus Images

  • Pereira, Joana
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Diabetic Retinopathy (DR) is a severe and widely spread eye disease. Exudates are one of the most prevalent signs during the early stage of DR and an early detection of these lesions is vital to prevent the patient’s blindness. Hence, detection of exudates is an important diagnostic task of DR, in which computer assistance may play a major role. In this paper, a system based on local feature extraction and Support Vector Machine (SVM) classification is used to develop and compare different strategies for automated detection of exudates. The main novelty of this work is allowing the detection of exudates using non-regular regions to perform the local feature extraction. To accomplish this objective, different methods for generating superpixels are applied to the fundus images of E-OPHTA database and texture and morphological features are extracted for each of the resulting regions. An exhaustive comparison among the proposed methods is also carried out., This paper was supported by the European Union’s Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT2016-2017, 732613]. The work of Adri´an Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.