Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RUC. Repositorio da Universidade da Coruña
Publicación Capítulo o parte de un libro (BookPart)

Fully automated identification and clinical classification of macular edema using optical coherence tomography images

  • Moura, Joaquim de
  • Samagaio, Gabriela
  • Novo Buján, Jorge
  • Fernández, María Isabel
  • Gómez-Ulla, Francisco
  • Ortega Hortas, Marcos
[Absctract]: Diabetic macular edema is a relevant ocular disease associated with diabetes mellitus that constitutes a concerning global health issue. This disease is one of the main causes of reversible blindness in industrialized countries, despite the availability of effective health interventions. This macular disorder is a consequence of the appearance of abnormal fluid regions within the main tissues of the retina that significantly decrease the patient's visual acuity. These fluid accumulations are also known as macular edemas (MEs). In this chapter, we present a computational methodology for the identification and clinical classification of ME using optical coherence tomography (OCT) scans, following the clinical classification of reference in the ophthalmological field. The presented system was tested with a dataset composed of 170 OCT scans retrieved from different patients that were labeled by a clinical expert. The presented system obtained satisfactory results in the localization of the area affected by each type of ME, even when they are combined in the same region of the retina. This fully automatic tool has demonstrated to be very useful not only for patients (helping in the early diagnosis of diseases that, consequently, improve their quality of life and well-being), but also in clinical systems by reducing costs., This work is supported by the Instituto de Salud Carlos III, Government of Spain and FEDER funds of the European Union through the DTS15/00153 and DTS18/00136 research projects and by the Ministerio de Ciencia, Innovacio´n y Universidades, Government of Spain through the DPI2015-69948-R and RTI2018- 095894-B-I00 research projects. Also, this work has received financial support from the European Union (European Regional Development Fund [ERDF]) and the Xunta de Galicia, Centro singular de investigacio´n de Galicia accreditation 2016–19, Ref. ED431G/01; and Grupos de Referencia Competitiva, Ref. ED431C 2016-047.
RUC. Repositorio da Universidade da Coruña
Publicación Capítulo o parte de un libro (BookPart)

Fully Automatic Epiretinal Membrane Segmentation in OCT Scans Using Convolutional Networks

  • Gende, M.
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
[Absctract]: The epiretinal membrane (ERM) is an ocular pathology that can cause visual distortions. To prevent a loss of vision, symptomatic ERM needs to be removed before it can cause irreversible damage. In order to do this, the ERM needs to be located early, so that it can be peeled from the retina. This chapter explores an automatic methodology for ERM segmentation, as well as its intuitive visualization in the form of colour maps. To do this, visual features that are compatible with ERM presence are extracted from ophthalmologic images by using computer vision algorithms and deep learning models. This methodology achieved satisfactory results, reaching a dice coefficient of 0.826 and a Jaccard index of 0.714, contributing to highlight the applicability of deep learning models for the detection of pathological signs in medical images., This research was funded by Instituto de Salud Carlos III, Government of Spain, [research project DTS18/00136]; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, [research project RTI2018-095894-B-I00]; Ministerio de Ciencia e Innovación, Government of Spain [research project PID2019-108435RB-I00]; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, [grant ref. ED431C 2020/24], predoctoral [grant ref. ED481A 2021/161] and postdoctoral [grant ref. ED481B 113 Fully Automatic Epiretinal Membrane Segmentation 2021/059]; Axencia Galega de Innovación (GAIN), Xunta de Galicia, [grant ref. IN845D 2020/38]; CITIC, Centro de Investigación de Galicia [grant ref. ED431G 2019/01], receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED481A 2021/161, Xunta de Galicia; ED481B 2021/059, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Capítulo o parte de un libro (BookPart)

Generation of Novel Synthetic Portable Chest X-Ray Images for Automatic COVID-19 Screening

  • Iglesias Morís, Daniel
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
in: Rajae El Ouazzani, Mohammed Fattah, Nabil Benamar (eds.) AI Applications for Disease Diagnosis and Treatment, IGI Global, 2022, [Abstract]: The diagnosis and the study of the evolution of COVID-19 is crucial to tackle the challenge that this disease represents for healthcare services. Chest x-ray imaging allows us to visualize the pulmonary regions, where COVID-19 causes its main affectation. In order to reduce the risk of cross-contamination, a crucial aspect in the pandemic, portable chest x-ray devices are advantageous being easier to decontaminate in comparison with the fixed machinery, despite offering a lower image quality. Furthermore, the recent emergence of COVID-19 implies a data scarcity that must be tackled. In this chapter, the authors present the analysis of a strategy that generates novel synthetic portable chest x-ray images using the CycleGAN, an architecture for image translation that is trained with unpaired data. The novel set of images is then added to the original dataset, improving the performance of the classification model., This research was funded by Instituto de Salud Carlos III, Government of Spain, [grant number DTS18/00136]; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, [grant number RTI2018-095894-B-I00]; Ministerio de Ciencia e Innovación, Government of Spain through the research project with [grant number PID2019-108435RB-I00]; Consellería de Cultura, Educación e Universidade, Xunta de Galicia through the predoctoral and postdoctoral grant contracts [grant number ED481A 2021/196] and [grant number ED481B 2021/059], respectively; and Grupos de Referencia Competitiva, [grant number ED431C 2020/24]; Axencia Galega de Innovación (GAIN), Xunta de Galicia, [grant number IN845D 2020/38]; CITIC, Centro de Investigación de Galicia [grant number ED431G 2019/01], receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED481A 2021/196, Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01, Xunta de Galicia; ED481B 2021/059
RUC. Repositorio da Universidade da Coruña
Publicación Capítulo o parte de un libro (BookPart)

Computerized tool for the automatic segmentation of DRT edemas using OCT scans

  • Moura, Joaquim de
  • Vidal, Plácido
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
Part of Photo Acoustic and Optical Coherence Tomography Imaging, Volume 1: Diabetic retinopathy (pp. 1-1). Bristol, UK: IOP Publishing. https://doi.org/10.1088/978-0-7503-2052-8, [Abstract]: This chapter presents a software tool for the automated segmentation of diffuse retinal thickening regions from optical coherence tomography (OCT) images. For this purpose, two retinal regions were defined and extracted: the inner retina and the outer retina. Then, a learning process was used to analyze a comprehensive and heterogeneous subset of relevant patterns in the OCT scans. Finally, two complementary post-processing stages were applied to improve the obtained performance and the overall efficiency of the presented tool. The presented tool achieved satisfactory performance, which demonstrates the suitability of the adopted solution., This research was funded by Instituto de Salud Carlos III, Government of Spain, DTS18/00136 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018–095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant reference FPU18/02271; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant reference ED431C 2020/24 and through the postdoctoral grant contract reference ED481B 2021/059; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant reference IN845D 2020/38; CITIC, Centro de Investigación de Galicia reference ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED481B 2021/059, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01