Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Study on Relevant Features in COVID-19 PCR Tests

  • Vidal, Plácido
  • Moura, Joaquim de
  • Ramos, Lucía
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
[Abstract] In the year 2020, the world suffered the effects of a global pandemic. COVID-19 is a disease that mainly affects the respiratory system of patients, even causing a disproportionate response of the immune system and further spreading the damage to other vital organs. The main means by which health care services detected this viral disease was through the use of Polymerase Chain Reactions (PCRs). These PCRs allow the detection of known chains of the genetic code of the virus in samples of sputum. In this work, we study PCR signal features that allow to automatize the analysis of hundreds of PCRs. The findings obtained from the study have shown these features to be capable of obtaining successful results in the detection of COVID-19 in PCR samples, with only a small fraction of the information extracted by the clinicians for that purpose., Xunta de Galicia; ED431G 2019/01, Instituto de Salud Carlos III, Government of Spain, DTS18/00136 research project; Ministerio de Ciencia, Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271; CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%).
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Analysis of Separability of COVID-19 and Pneumonia in Chest X-ray Images by Means of Convolutional Neural Networks

  • Moura, Joaquim de
  • Ramos, Lucía
  • Vidal, Plácido
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
[Abstract] The new coronavirus (COVID-19) is a disease that is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). On 11 March 2020, the coronavirus outbreak has been labelled a global pandemic by the World Health Organization. In this context, chest X-ray imaging has become a remarkably powerful tool for the identification of patients with COVID-19 infections at an early stage when clinical symptoms may be unspecific or sparse. In this work, we propose a complete analysis of separability of COVID-19 and pneumonia in chest X-ray images by means of Convolutional Neural Networks. Satisfactory results were obtained that demonstrated the suitability of the proposed system, improving the efficiency of the medical screening process in the healthcare systems., This work is supported by the Instituto de Salud Carlos III, Government of Spain and FEDER funds of the European Union through the DTS18/00136 research projects and by the Ministerio de Ciencia, Innovación y Universidades, Government of Spain through the RTI2018-095894-B-I00 research projects, as well as through Ayudas para la formación de profesorado universitario (FPU), Ref. FPU18/02271. Also, this work has received financial support from the European Union (European Regional Development Fund—ERDF) and the Xunta de Galicia, Centro de Investigación del Sistema Universitario de Galicia, Ref. ED431G 2019/01., Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

COVID-19 Lung Radiography Segmentation by Means of Multiphase Transfer Learning

  • Vidal, Plácido
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
Presented at the 4th XoveTIC Conference, A Coruña, Spain, 7–8 October 2021., [Abstract] COVID-19 is characterized by its impact on the respiratory system and, during the global outbreak of 2020, specific protocols had to be designed to contain its spread within hospitals. This required the use of portable X-ray devices that allow for a greater flexibility in terms of their arrangement in rooms not specifically designed for such purpose. However, their poor image quality, together with the subjectivity of the expert, can hinder the diagnosis process. Therefore, the use of automatic methodologies is advised. Even so, their development is challenging due to the scarcity of available samples. For this reason, we present a COVID-19-specific methodology able to segment these portable chest radiographs with a reduced number of samples via multiple transfer learning phases. This allows us to extract knowledge from two related fields and obtain a robust methodology with limited data from the target domain. Our proposal aims to help both experts and other computer-aided diagnosis systems to focus their attention on the region of interest, ignoring unrelated information., Instituto de Salud Carlos III, Government of Spain, DTS18/00136 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24 and through the postdoctoral grant contract ref. ED481B 2021/059; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38; CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%), Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED481B 2021/059, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Transformer-Based Multi-Prototype Approach for Diabetic Macular Edema Analysis in OCT Images

  • Vidal, Plácido
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
  • Cardoso, Jaime S.
© 2023 IEEE. This version of the paper has been accepted for publication. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The final published paper is available online at: https://doi.org/10.1109/ICASSP49357.2023.10095039, Presentado en: ICASSP 2023 - 2023 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Rhodes Island, Greece, 04-10 June 2023, [Abstract]: Optical Coherence Tomography (OCT) is the major diagnostic tool for the leading cause of blindness in developed countries: Diabetic Macular Edema (DME). Depending on the type of fluid accumulations, different treatments are needed. In particular, Cystoid Macular Edemas (CMEs) represent the most severe scenario, while Diffuse Retinal Thickening (DRT) is an early indicator of the disease but a challenging scenario to detect. While methodologies exist, their explanatory power is limited to the input sample itself. However, due to the complexity of these accumulations, this may not be enough for a clinician to assess the validity of the classification. Thus, in this work, we propose a novel approach based on multi-prototype networks with vision transformers to obtain an example-based explainable classification. Our proposal achieved robust results in two representative OCT devices, with a mean accuracy of 0.9099 ± 0.0083 and 0.8582 ± 0.0126 for CME and DRT-type fluid accumulations, respectively., This research was funded by Instituto de Salud Carlos III, Government of Spain, PI17/00940 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271 and Ayudas complementarias de movilidad destinadas a beneficiarios del programa de Formación del Profesorado Universitario (FPU) EST22/00696; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38;CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Pulmonary-Restricted COVID-19 Informative Visual Screening Using Chest X-ray Images from Portable Devices

  • Vidal, Plácido
  • Moura, Joaquim de
  • Ortega Hortas, Marcos
This version of the conference paper has been accepted for publication, after peer review and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/978-3-031-06427-2_6., The conference was held during May 23-27, 2022, in Lecce, Italy., [Abstract]: In the recent COVID-19 outbreak, chest X-rays were the main tool for diagnosing and monitoring the pathology. To prevent further spread of this disease, special circuits had to be implemented in the healthcare services. For this reason, these chest X-rays were captured with portable X-ray devices that compensate its lower quality and limitations with more deployment flexibility. However, most of the proposed computer-aided diagnosis methodologies were designed to work with traditional fixed X-ray machines and their performance is diminished when faced with these portable images. Additionally, given that the equipment needed to properly treat the disease (such as for life support and monitoring of vital signs) most of these systems learnt to identify these artifacts in the images instead of real clinically-significant variables. In this work, we present the first methodology forced to extract features exclusively from the pulmonary region of interest that is specially designed to work with these difficult portable images. Additionally, we generate a class activation map so the methodology also provides explainability to the results returned to the clinician. To ensure the robustness of our proposal, we tested the methodology with chest radiographs from patients diagnosed with COVID-19, pathologies similar to COVID-19 (such as other types of viral pneumonias) and healthy patients in different combinations with three convolutional networks from the state of the art (for a total of 9 studied scenarios). The experimentation confirms that our proposal is able to separate COVID-19 cases, reaching a 94.7% ± 1.34% of accuracy., This research was funded by Instituto de Salud Carlos III, Government of Spain, DTS18/00136 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271; Ministerio de Ciencia e Innovación, Government of Spain through the research project PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24 and through the postdoctoral grant contract ref. ED481B 2021/059; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38; CITIC, as Research Center accredited by Galician University System, is funded by “Consellería de Cultura, Educación e Universidade from Xunta de Galicia”, supported in an 80% through ERDF Funds, ERDF Operational Programme Galicia 2014–2020, and the remaining 20% by “Secretaría Xeral de Universidades” (Grant ED431G 2019/01)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED481B 2021/059, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Comparative and Behavioural Analysis of a Diffuse Paradigm for the Evaluation of Diabetic Macular Edema in OCT images

  • Vidal, Plácido
  • Moura, Joaquim de
  • Díaz, Macarena
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
The conference was held during June 7 to 9, 2021 Aveiro, Portugal., This version of the paper has been accepted for publication. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The final published paper is available online at: https://doi.org/10.1109/CBMS52027.2021.00010, [Abstract]: Nowadays, Diabetic Macular Edema (DME) is one of the leading causes of blindness in developed countries, and its characterized by the presence of pathological fluid accumulations inside the retinal layers. Currently, the main way to detect these fluid accumulations (as well as their severity) is through the use of Optical Coherence Tomography (OCT) imaging. In particular, this ophthalmological image modality allows a precise non-invasive analysis of the morphology of the retina and its structures. Due to the complexity of attempting to successfully segment these fluid accumulations, an alternative paradigm for their detection has been recently proposed. This paradigm, based on a diffuse representation of the pathological regions, creates an intuitive representation of the pathological regions based on a confidence map. Currently, there are only two approaches for this paradigm: one based on a predefined library of texture and intensity features with established machine learning algorithms and other based on deep learning methods. Both approaches have proven to offer satisfactory results, but each one of them performs better in different scenarios. In this work, we perform a complete analysis and comparison on the behaviour and performance of both strategies in a clinical screening scenario to evaluate the suitability of both approaches for the clinical practice as well as their performance as computer vision strategies., This research was funded by Instituto de Salud Carlos III, Government of Spain, DTS18/00136 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00 ; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24 ; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38 ; CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Region of interest-bounded COVID-19 lung screening using images from portable X-ray devices

  • Vidal, Plácido
  • Moura, Joaquim de
  • Ramos, Lucía
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
Comunicación presentada al V Congreso XoveTIC, organizado por el Centro de Investigación en TIC da Universidade da Coruña (CITIC), os días 5 y 6 de octubre de 2022, [Abstract]: X-ray analysis of the lungs was the main method to assess the degree of affliction of SARS-COV-2. Due to the high contagiousness of this pathology, this assessment was conducted using portable X-ray devices. Automatic methodologies were proposed to compensate the image quality of said portable X-ray devices. However, these methodologies were shown to be exploiting external information (such as pacemakers or ventilators present in the images) to determine the severity. For this reason, we present a methodology specially designed to reduce the effect on an automatic methodology of these extraneous artifacts. We extract the lung region and we perform a screening of the presence of the pathology using only the pulmonary region. Finally, to ascertain the performance of the system (and provide explainability to the clinical experts), we generate the corresponding activation maps. The presented methodology has achieved a more than satisfactory performance in all the scenarios and the activation maps clearly indicate that the system is successfully using information from the lung region while excluding elements unrelated to the disease., This research was funded by: Instituto de Salud Carlos III - DTS18/00136; Ministerio de Ciencia e Innovación y Universidades, Gov. of Spain - RTI2018-095894-B-I00, Ayudas para la formación de prof. universitario (FPU)- FPU18/02271; Ministerio de Ciencia e Innovación, Gov. of Spain - PID2019-108435RB-I00; Conselleria de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva - ED431C 2020/24; Axencia Galega de Innovación (GAIN), Xunta de Galicia - IN845D 2020/38; CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED431G 2019/01, Xunta de Galicia; IN845D 2020/38