Pasar al contenido principal

-

IJCI-2014-22178

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprograma Subprograma Estatal de Incorporación
Convocatoria Juan de la Cierva Incorporación
Año convocatoria 2014
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Secretaría de Estado de Educación, Formación Profesional y Universidades
Centro beneficiario FUNDACION PARA INVESTIGACION BIOMEDICA HOSPITAL G. MARAÑON
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Effects of Geometry in Atrial Fibrillation Markers Obtained With Electrocardiographic Imaging

  • Molero-Alabau, Rubén
  • Hernández-Romero, Ismael
  • Liberos, Alejandro
  • Fernández-Avilés, Francisco
  • Atienza, Felipe
  • Rodrigo, Miguel
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Electrocardiographic imaging (ECGI) can characterise cardiac pathologies such as atrial fibrillation (AF) through specific markers based on frequency or phase analysis. In this study, the effect of the geometry of patients torso and atria in the ECGI resolution is studied. A realistic 3D atrial geometry was located on 30 patient torsos and ECGI signals were calculated for 30 different AF simulations in each torso. Dominant frequency (DF) and reentrant activity analysis were calculated for each scenario. Anatomical and geometrical measurements of each torso (30-80% of variability between patients) and atria were calculated and compared with the errors in the ECGI estimation versus the departing EGM maps. Results show evidences that big chest dimensions worsen the non-invasive calculation of AF markers (p<0.05). Also, higher number of visible electrodes from each atrial region improves ECGI characterization measured as lower DF deviations (0.64±0.26 Hz vs 0.72±0.27 Hz, p<0.05) and higher reentrant activity coincidence (10.1±12.2% vs 3.4±3.4%, p<0.05). Torso and atrial geometry affect the quality of the non-invasive reconstruction of AF markers such as DF or reentrant activity. Knowing the geometrical parameters that worsen non-invasive AF maps may help to measure each detected AF driver reliability., Supported in part by: Instituto de Salud Carlos III FEDER (Fondo Europeo de Desarrollo Regional; IJCI2014-22178, DTS16/00160; PI14/00857, PI16/01123; PI17/01059; PI17/01106), Generalitat Valenciana Grants (APOSTD/2017 and APOSTD/2018) and projects (GVA/2018/103) and EIT-Health 19600 AFFINE.