DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación
Contribución de congreso (ConferenceOutput)
Design of a compact rotating magnetic refrigerator
Trabajo presentado al Danish Days on Caloric Materials and Devices, celebrado en Roskilde (Dinamarca) del 2 al 3 de octubre de 2017., The design of a magnetocaloric effect (MCE) refrigerator is a challenging problem. The task turns out a lot more demanding if the target includes a wide temperature span, a compact design and including a modular graded active magnetic regenerator (AMR) that allows using different magnetocaloric material (MCM) combinations. A modular, graded AMR has been designed to allow the use of shorter AMR stacks, lowering in thisway the pressure loss. The AMR consists of eight beds covering 45º each, with alternative activation in groups of four. The magnet is rotated by means of a slewing ring gear and the core, the AMR and, therefore, the fluid distribution system arestatic; no fluid rotaryvalvesare
needed. Fluid flow is controlled by means of high speed solenoid valves, which allow the control of the fluid flow sequence by means of software. These valves have a response time of about 20 ms and allow flows of 0.2 l/s at a pressure of 8 bar. The working cycle includes four steps: magnetization with blow, static heat balancing, demagnetization with opposite blow, and static
heat balancing. The fluid flow is unidirectional, with no dead volumes. The global flow is constant, but the alternative use of half of the beds, allows the static heat balancing steps. The eight AMR beds work in parallel pairs connected in series with another pair, with the cold spot in between. The cold spot consists of a block of four soldered copper circuits that allow good thermal contact but no fluid mix. Most of the fluid circuit’s elements remain on the hot side to further reduce thermal losses in the cold side. The magnet design follows the general configuration described in. It has been optimized in angular width and direction of each NdFeB sector’s magnetization, resulting in Bmax=1.86 T, Bmin=0.003 T and, for each 45º sector of the AMR, <Bmax>=1.71 T and <Bmin>=0.015 T. Small spheres of MCM with first and second order transitions are used and they have been modelled to carry out simulations using a modified version of the procedure described in., The authors acknowledge BSH Electrodomésticos España contract 2013/0011, the Spanish MINECO project MAT2013-44063R and DGA Consolidated Group E100., Peer Reviewed