Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Clinical Decision Support Tool for the Identification of Pathological Structures Associated with Age-Related Macular Degeneration

  • Barrientos Lema, Iván
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
  • Penedo, Manuel
18th International Conference on Computer Aided Systems Theory, EUROCAST 2022, Las Palmas de Gran Canaria, 20 - 25 February 2022, This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature's AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/978-3-031-25312-6_48, [Abstract]: In the field of ophthalmology, different imaging modalities are commonly used to carry out different clinical diagnostic procedures. Currently, both optical coherence tomography (OCT) and optical coherence tomography angiography (OCT-A) have made great advances in the study of the posterior pole of the eye and are essential for the diagnosis and monitoring of the treatment of different ocular and systemic diseases. On the other hand, the development of clinical decision support systems is an emerging field, in which clinical and technological advances are allowing clinical specialists to diagnose various pathologies with greater precision, which translates into more appropriate treatment and, consequently, an improvement in the quality of life of patients. This paper presents a clinical decision support tool for the identification of different pathological structures associated with age-related macular degeneration using OCT and OCT-A images. The system provides a useful tool that facilitates clinical decision-making in the diagnosis and treatment of this relevant disease., This research was funded by Instituto de Salud Carlos III, Government of Spain, DTS18/00136 and PI17/00940 research projects; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24 and postdoctoral grant ref. ED481B 2021/059; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38; CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Con-sellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; ED481B 2021/059, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Transformer-Based Multi-Prototype Approach for Diabetic Macular Edema Analysis in OCT Images

  • Vidal, Plácido
  • Moura, Joaquim de
  • Novo Buján, Jorge
  • Ortega Hortas, Marcos
  • Cardoso, Jaime S.
© 2023 IEEE. This version of the paper has been accepted for publication. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The final published paper is available online at: https://doi.org/10.1109/ICASSP49357.2023.10095039, Presentado en: ICASSP 2023 - 2023 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Rhodes Island, Greece, 04-10 June 2023, [Abstract]: Optical Coherence Tomography (OCT) is the major diagnostic tool for the leading cause of blindness in developed countries: Diabetic Macular Edema (DME). Depending on the type of fluid accumulations, different treatments are needed. In particular, Cystoid Macular Edemas (CMEs) represent the most severe scenario, while Diffuse Retinal Thickening (DRT) is an early indicator of the disease but a challenging scenario to detect. While methodologies exist, their explanatory power is limited to the input sample itself. However, due to the complexity of these accumulations, this may not be enough for a clinician to assess the validity of the classification. Thus, in this work, we propose a novel approach based on multi-prototype networks with vision transformers to obtain an example-based explainable classification. Our proposal achieved robust results in two representative OCT devices, with a mean accuracy of 0.9099 ± 0.0083 and 0.8582 ± 0.0126 for CME and DRT-type fluid accumulations, respectively., This research was funded by Instituto de Salud Carlos III, Government of Spain, PI17/00940 research project; Ministerio de Ciencia e Innovación y Universidades, Government of Spain, RTI2018-095894-B-I00 research project, Ayudas para la formación de profesorado universitario (FPU), grant ref. FPU18/02271 and Ayudas complementarias de movilidad destinadas a beneficiarios del programa de Formación del Profesorado Universitario (FPU) EST22/00696; Ministerio de Ciencia e Innovación, Government of Spain through the research project with reference PID2019-108435RB-I00; Consellería de Cultura, Educación e Universidade, Xunta de Galicia, Grupos de Referencia Competitiva, grant ref. ED431C 2020/24; Axencia Galega de Innovación (GAIN), Xunta de Galicia, grant ref. IN845D 2020/38;CITIC, Centro de Investigación de Galicia ref. ED431G 2019/01, receives financial support from Consellería de Educación, Universidade e Formación Profesional, Xunta de Galicia, through the ERDF (80%) and Secretaría Xeral de Universidades (20%)., Xunta de Galicia; ED431C 2020/24, Xunta de Galicia; IN845D 2020/38, Xunta de Galicia; ED431G 2019/01