Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

The XGIS imaging system on board the THESEUS mission

  • Gasent-Blesa, José Luis
  • Castro-Tirado, Alberto J.
  • Caballero Garcia, M. D.
Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray; Virtual, Online; United States; 14 December 2020 through 18 December 2020; Code 166330.--Proceedings of SPIE - The International Society for Optical Engineering Volume 11444, 2020, Article number 114448S.--Full list of authors: Gasent-Blesa, J. L.; Reglero, V.; Connell, P.; Pinazo-Herrero, B.; Navarro-González, J.; Rodríguez-Martínez, P.; Castro-Tirado, A. J.; Caballero-García, M. D.; Amati, L.; Labanti, C.; Mereghetti, S.; Frontera, F.; Campana, R.; Orlandini, M.; Stephen, J.; Terenzi, L.; Evangelisti, F.; Squerzanti, S.; Melchiorri, M.; Fuschino, F. De Rosa, A.; Morgante, G., Within the scientific goals of the THESEUS ESA/M5 candidate mission, a critical item is a fast (within a few s) and accurate (<15 arcmin) Gamma-Ray Burst and high-energy transient location from a few keV up to hard X-ray energy band. For that purpose, the signal multiplexing based on coded masks is the selected option to achieve this goal. This contribution is implemented by the XGIS Imaging System, based on that technique. The XGIS Imaging System has the heritage of previous payload developments: LEGRI/Minisat-01, INTEGRAL, UFFO/Lomonosov and ASIM/ISS. In particular the XGIS Imaging System is an upgrade of the ASIM system in operation since 2018 on the International Space Station. The scientific goal is similar: to detect a gamma-ray transient. But while ASIM focuses on Terrestrial Gamma-ray Flashes, THESEUS aims for the GRBs. For each of the two XGIS Cameras, the coded mask is located at 630 mm from the detector layer. The coding pattern is implemented in a Tungsten plate (1 mm thickness) providing a good multiplexing capability up to 150 keV. In that way both XGIS detector layers (based on Si and CsI detectors) have imaging capabilities at the medium - hard X-ray domain. This is an improvement achieved during the current THESEUS Phase-A. The mask is mounted on top of a collimator that provides the mechanical assembly support, as well as good cosmic X-ray background shielding. The XGIS Imaging System preliminary structural and thermal design, and the corresponding analyses, are included in this contribution, as it is a preliminary performance evaluation. © 2020 SPIE, THESEUS/XGIS instrument is supported by: the ASI-INAF Agreement n. 2018-29-HH.0; the OHB Italia/INAF-OASBo Agreement n.2331/2020/01; the European Space Agency ESA through the M5/NPMC Programme; the AHEAD2020 project funded by the UE through H2020-INFRAIA-2018-2020; the Spanish Ministerio de Ciencia e Innovaci?n, PID2019 109269RB-C41; the Polish National Science Centre, Project 2019/35/B/ST9/03944 and Foundation for Polish Science, Project POIR.04.04.00-00-5C65/17-00. The authors thank all the members of the THESEUS team involved in the development of XGIS instrument.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

The X/Gamma-ray Imaging Spectrometer (XGIS) on-board THESEUS: Design, main characteristics, and concept of operation

  • Labanti, C.
  • Castro-Tirado, Alberto J.
Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray; Virtual, Online; United States; 14 December 2020 through 18 December 2020; Code 166330.--Proceedings of SPIE - The International Society for Optical Engineering Volume 11444, 2020, Article number 114442K.--Full list of authors: Labanti, C.; Amati, L.; Frontera, F.; Mereghetti, S.; Gasent-Blesa, J. L.; Tenzer, C.; Orleanski, P.; Kuvvetli, I.; Campana, R.; Fuschino, F.; Terenzi, L.; Virgilli, E.; Morgante, G.; Orlandini, M.; Butler, R. C.; Stephen, J. B.; Auricchio, N.; De Rosa, A.; Da Ronco, V.; Evangelisti, F. Melchiorri, M.; Squerzanti, S.; Fiorini, M.; Bertuccio, G.; Mele, F.; Gandola, M.; Malcovati, P.; Grassi, M.; Bellutti, P.; Borghi, G.; Ficorella, F.; Picciotto, A.; Zanini, V.; Zorzi, N.; Demenev, E.; Rashevskaya, I.; Rachevski, A.; Zampa, G.; Vacchi, A.; Zampa, N.; Baldazzi, G.; La Rosa, G.; Sottile, G.; Volpe, A.; Winkler, M.; Reglero, V.; Connell, P. H.; Pinazo-Herrero, B.; Navarro-González, J.; Rodríguez-Martínez, P.; Castro-Tirado, A. J.; Santangelo, A.; Hedderman, P.; Lorenzi, P.; Sarra, P.; Pedersen, S. M.; Tcherniak, D.; Guidorzi, C.; Rosati, P.; Trois, A.; Piazzolla, R., THESEUS (Transient High Energy Sky and Early Universe Surveyor) is one of the three missions selected by ESA as fifth medium class mission (M5) candidates in its Cosmic Vision science program, currently under assessment in a phase A study with a planned launch date in 2032. THESEUS is designed to carry on-board two wide and deep sky monitoring instruments for X/gamma-ray transients detection: a wide-field soft X-ray monitor with imaging capability (Soft X-ray Imager, SXI, 0.3 - 5 keV), a hard X-ray, partially-imaging spectroscopic instrument (X and Gamma Imaging Spectrometer, XGIS, 2 keV - 10 MeV), and an optical/near-IR telescope with both imaging and spectroscopic capability (InfraRed Telescope, IRT, 0.7 - 1.8 µm). The spacecraft will be capable of performing fast repointing of the IRT to the error region provided by the monitors, thus allowing it to detect and localize the transient sources down to a few arcsec accuracy, for immediate identification and redshift determination. The prime goal of the XGIS will be to detect transient sources, with monitoring timescales down to milliseconds, both independently of, or following up, SXI detections, and identify the sources performing localisation at <15 arcmin and characterize them over a broad energy band, thus providing also unique clues to their emission physics. The XGIS system consists of two independent but identical coded mask cameras, arranged to cover 2 steradians. The XGIS will exploit an innovative technology coupling Silicon Drift Detectors (SDD) with crystal scintillator bars and a very low-noise distributed front-end electronics (ORION ASICs), which will produce a position sensitive detection plane, with a large effective area over a huge energy band (from soft X-rays to soft gamma-rays) with timing resolution down to a few µs. Here is presented an overview of the XGIS instrument design, its configuration, and capabilities. © 2020 SPIE, The Phase A study of the THESEUS/XGIS instrument is supported by ASI-INAF Agreement n. 2018-29-HH.0, OHB Italia/ - INAF-OASBo Agreement n.2331/2020/01, by the European Space Agency ESA through the M5/NPMC Programme and by the AHEAD2020 project funded by UE through H2020-INFRAIA-2018-2020. By the Spanish Ministerio de Ciencia e Innovación, PID2019-109269RB-C41. By Polish National Science Center, Project 2019/35/B/ST9/03944 and Foundation for Polish Science, Project POIR.04.04.00-00-5C65/17-00.
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Recurrent lightning spots with different lightning return period

  • Solà de las Fuentes, Glòria|||0000-0002-0665-6225
  • López Trujillo, Jesús Alberto|||0000-0002-8802-4271
  • Montanya Puig, Joan
  • Pineda Rüegg, Nicolau|||0000-0002-2507-8424
Recurrent lightning spots (RLS) is a recent concept that explores places that experience lightning year after year. This article presents an analysis of the RLS concerning the recurrence interval. We adapt the concept of the return periods to refer to this time interval. The variation in different lightning return period made that new RLS appear. The region of study is centred in Catalonia (Spain, Europe) using LINET lightning data. The methodology is described. Results show that just one RLS fulfills a half-year return period, while the number of RLS significantly increases when the lightning return period is longer than one year. The RLS return period criteria could be used as a reference for maintenance and/or inspection, in particular for sensitive applications such as wind turbines., This work was also supported by research Grant ESP2017-86263-C4-2-R funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”, by the “European Union”; and Grants PID2022-136348NB-C32, PID2019-109269RBC42, EQC2021-006957-P, and ENE2017-91636-EXP funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Small scale simulation of lightning using vertical wires deployed by drones: on the land and sea peak current asymetry

  • Montañá Puig, Juan|||0000-0003-2488-697X
  • Fontanes Molina, Pol|||0000-0001-8185-6350
  • Arcanjo, Marcelo
  • Urbani, Michele|||0000-0002-9148-2740
  • Williams, Earle Rolfe
  • Romero Durán, David|||0000-0002-5571-9069
  • Horta Bernús, Ricard|||0000-0003-3536-4595
  • López Trujillo, Jesús Alberto|||0000-0002-8802-4271
  • Van der Velde, Oscar Arnoud|||0000-0002-1638-6628
  • Pineda Rüegg, Nicolau|||0000-0002-2507-8424
In this work we simulate lightning by means of vertical wires deployed by a multirotor drone under fair weather conditions. These wires, when isolated from ground, acquire an electric potential by virtue of electrostatic induction by the atmospheric potential. When the wires are short circuited to ground or seawater a current is measured sharing some features similar to return strokes in lightning. The results show how currents have higher amplitudes when the wires are short circuited to seawater compared to ground., This work was supported by a research grant from the Spanish Ministry of Economy EXPLORA call with reference ENE2017-91636-EXP and the Grant PID2019-109269RBC42 funded by MCIN/AEI/10.13039/501100011033. This work is also supported by the MIT MISTI Global Seed Funds MIT-Spain ‘La Caixa’ projects “Smart Lightning Protection Systems for Wind Turbines and Aircraft” and “Small Unmanned Airborne Systems for Atmospheric Electricity Research”. Also, the Industrial Doctorate grant of the AGAUR with reference to 2019 DI 039 ., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

New era of lightning detection from space: application to electric power systems

  • Montañá Puig, Juan|||0000-0003-2488-697X
  • López Trujillo, Jesús Alberto|||0000-0002-8802-4271
  • Van der Velde, Oscar Arnoud|||0000-0002-1638-6628
  • Solà de las Fuentes, Glòria|||0000-0002-0665-6225
  • Romero Durán, David|||0000-0002-5571-9069
  • Morales Rodríguez, Carlos Augusto
  • Visacro, Silverio
  • Goodman, Steven J.
  • Williams, Earle Rolfe
  • Peterson, Michael J.
  • Pineda Rüegg, Nicolau|||0000-0002-2507-8424
  • Sousa Arcanjo, Marcelo Augusto|||0000-0002-8620-5079
  • Aranguren Fino, Harby Daniel
Information about lightning activity and its parameters is necessary to design and evaluate the lightning protection of an electrical power system. This information can be obtained from ground-based lightning detection networks that provide information on cloud-to-ground lightning strikes with a location accuracy of few hundred meters. Recently, the first satellite-based lightning optical detectors are operating continuously from geostationary orbits. These imagers observe the luminosity escaping from clouds to detect and locate total lightning activity with a spatial accuracy of several kilometers. This allows delineating the initiation and propagation (sometimes over tens to hundreds of kilometers before striking the ground) not observable by the ground-based networks. In this paper, we explore the use of this new technology for lightning protection in power systems., This work was supported by research grants from the Spanish Ministry of Economy and the European Regional Development Fund (FEDER): ESP2017-86263-C4-2-R and PID2019-109269RB-C42. S. Goodman was in part supported by NASA Grant 80NSSC18K1689., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

New era of lightning detection from space: application to electric power systems

  • Montañá Puig, Juan
  • López Trujillo, Jesús Alberto
  • Van der Velde, Oscar Arnoud
  • Solà de las Fuentes, Glòria
  • Romero Durán, David
  • Morales Rodríguez, Carlos Augusto
  • Visacro, Silverio
  • Goodman, Steven J.
  • Williams, Earle Rolfe
  • Peterson, Michael J.
  • Pineda Rüegg, Nicolau
  • Sousa Arcanjo, Marcelo Augusto
  • Aranguren Fino, Harby Daniel
Information about lightning activity and its parameters is necessary to design and evaluate the lightning protection of an electrical power system. This information can be obtained from ground-based lightning detection networks that provide information on cloud-to-ground lightning strikes with a location accuracy of few hundred meters. Recently, the first satellite-based lightning optical detectors are operating continuously from geostationary orbits. These imagers observe the luminosity escaping from clouds to detect and locate total lightning activity with a spatial accuracy of several kilometers. This allows delineating the initiation and propagation (sometimes over tens to hundreds of kilometers before striking the ground) not observable by the ground-based networks. In this paper, we explore the use of this new technology for lightning protection in power systems., This work was supported by research grants from the Spanish Ministry of Economy and the European Regional Development Fund (FEDER): ESP2017-86263-C4-2-R and PID2019-109269RB-C42. S. Goodman was in part supported by NASA Grant 80NSSC18K1689., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Small scale simulation of lightning using vertical wires deployed by drones: on the land and sea peak current asymetry

  • Montañá Puig, Juan
  • Fontanes Molina, Pol
  • Arcanjo, Marcelo
  • Urbani, Michele
  • Williams, Earle Rolfe
  • Romero Durán, David
  • Horta Bernús, Ricard
  • López Trujillo, Jesús Alberto
  • Van der Velde, Oscar Arnoud
  • Pineda Rüegg, Nicolau
In this work we simulate lightning by means of vertical wires deployed by a multirotor drone under fair weather conditions. These wires, when isolated from ground, acquire an electric potential by virtue of electrostatic induction by the atmospheric potential. When the wires are short circuited to ground or seawater a current is measured sharing some features similar to return strokes in lightning. The results show how currents have higher amplitudes when the wires are short circuited to seawater compared to ground., This work was supported by a research grant from the Spanish Ministry of Economy EXPLORA call with reference ENE2017-91636-EXP and the Grant PID2019-109269RBC42 funded by MCIN/AEI/10.13039/501100011033. This work is also supported by the MIT MISTI Global Seed Funds MIT-Spain ‘La Caixa’ projects “Smart Lightning Protection Systems for Wind Turbines and Aircraft” and “Small Unmanned Airborne Systems for Atmospheric Electricity Research”. Also, the Industrial Doctorate grant of the AGAUR with reference to 2019 DI 039 ., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Recurrent lightning spots with different lightning return period

  • Solà de las Fuentes, Glòria
  • López Trujillo, Jesús Alberto
  • Montanya Puig, Joan
  • Pineda Rüegg, Nicolau
Recurrent lightning spots (RLS) is a recent concept that explores places that experience lightning year after year. This article presents an analysis of the RLS concerning the recurrence interval. We adapt the concept of the return periods to refer to this time interval. The variation in different lightning return period made that new RLS appear. The region of study is centred in Catalonia (Spain, Europe) using LINET lightning data. The methodology is described. Results show that just one RLS fulfills a half-year return period, while the number of RLS significantly increases when the lightning return period is longer than one year. The RLS return period criteria could be used as a reference for maintenance and/or inspection, in particular for sensitive applications such as wind turbines., This work was also supported by research Grant ESP2017-86263-C4-2-R funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”, by the “European Union”; and Grants PID2022-136348NB-C32, PID2019-109269RBC42, EQC2021-006957-P, and ENE2017-91636-EXP funded by MCIN/AEI/10.13039/501100011033., Peer Reviewed, Preprint