Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Energy optimization of a thermal storage tank for Domestic Hot Water production

  • Masip, X.
  • Hervas-Blasco, Estefanía
  • Corberán, José M.
  • Álvarez-Piñeiro, Lucas|||0000-0002-9450-2479
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] According to the European Commission, the residential sector is responsible at this moment of the 40 % of the energy consumption and 36 % of the associated CO2 emissions in Europe. Regarding the water heating consumption, it is currently responsible for 14.5 % energy consumption of the average European dwelling. This percentage is expected to increase drastically within the concept of Near Zero Energy Building (NZEB) since the associated heating consumption percentage will be decreased largely. In this way, the energy consumption associated for water heating should be reduced, and it only can be done by using highly energy efficient technologies, such as heat pump (HP), and decreasing the energy losses associated to the facilities. In the frame of the European Project NEXTHPG of the 7th framework program, a new prototype of heat pump booster for the production of domestic hot water was developed. The developed prototype uses an innovative subcooling control system, which allows increasing the COP of the system in more than 30% compared to conventional subcritical heat pump systems. Nevertheless, in a real installation apart from the heat pump there are other factors contributing to the final energy consumption of the whole system like system configuration, control algorithm, tank size and the like. Therefore, an estimation of the final energy consumption of the system could be significantly different from the obtained taking into account only the pump performance. The present work is focused on the development of a model in order to optimize the design of the whole system using the prototype of the NEXTHPG project in order to satisfy the domestic hot water demand of a building for 20 people. The integrated system model will include the heat pump, the water tank, a heat exchanger in order to recover part of the waste heat (such as the heat coming from the sewage water in the domestic sector or from condensing loops in tertiary sector) and a random generator of domestic hot water demand profile. From the results of this work, the proper sizing of the heat pump and the water tank, as well as the control algorithm, are obtained and the potential annual energy consumption of this type of system is estimated., Part of the work presented was carried by Estefanía Hervás Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD¿, thorugh the project. MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DE CONSUMO CASI NULO with the reference ENE2017-83665-C2-1-P for the given support and REDUCCIÓN DE LAS EMISIONES DE CO2 EN LA PRODUCCIÓN DE AGUA CALIENTE A ALTA TEMPERATURA A PARTIR DE LA RECUPERACIÓN DE CALOR RESIDUAL MEDIANTE EL USO DE UNA BOMBA DE CALOR with the reference SP20180039.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Heat Pump control comparison of a conventional superheat system over a subcooling control system for Domestic Hot Water production

  • Masip, X.
  • Hervas-Blasco, Estefanía
  • Corberán, José M.
  • Álvarez-Piñeiro, Lucas|||0000-0002-9450-2479
  • Navarro-Peris, Emilio|||0000-0002-0608-2129
[EN] The water heating consumption of the average European dwelling accounts at this moment for 14.5 %, according to the European Commission, whereas heating and cooling percentage account for 64.7 %. The European Union, with the introduction of the Nearly Zero Energy Buildings (NZEB) concept, intends to decrease in a great amount the total energy consumption of the residential sector acting over the percentage associated to heating. This will have an effect on the water heating consumption, increasing its consumption percentage. Therefore, in order to reduce the residential sector consumption and more concretely the percentage associated to water heating consumption, it will be key the use of highly energy efficient technologies since it is not possible to reduce the water heating energy consumption by acting on the demand without the risk of not satisfying the user comfort. In that sense, heat pumps are a technology of increasing interest. It is considered as renewable when its SPF is above 2.5, its production does not depend on external factors (as sunlight) and will play a key role in the cities of the future since it has the capability of acting as a booster from heat distribution networks. At this moment, the heat pumps available in the market for domestic hot water production using subcritical cycles are cost-effective but its design does not differ significantly from the used for heating applications. In the frame of the European project NEXTHPG, a heat pump system specifically designed for domestic hot water production with a variable subcooling control was developed. In this work, a comparison between the energy consumption at the system level of this prototype with a commercial water-to-water heat pump for domestic hot water production is performed. The results show a big difference in terms of energy efficiency between both cases. The variable subcooling case results in a 26.68 % positive energy efficiency difference regarding the conventional case when compared in their maximum efficiency point. The sizing of the heat pump-storage tank duality plays an important role since it could lead to an energy efficiency loss of almost 17 %. These results show clearly the advantages of the innovative heat pump model in front of the conventional heat pumps used for domestic hot water production., Part of the work presented was carried by Estefanía Hervás Blasco with the financial support of a PhD scholarship from the Spanish government SFPI1500 x 074478XV0. The authors would like also to acknowledge the Spanish MINISTERIO DE ECONOMIA Y COMPETITIVIDAD, through the project. MAXIMIZACION DE LA EFICIENCIA Y MINIMIZACION DEL IMPACTO AMBIENTAL DE BOMBAS DE CALOR PARA LA DESCARBONIZACION DE LA CALEFACCION/ACS EN LOS EDIFICIOS DE CONSUMO CASI NULO with the reference ENE2017-83665-C2-1-P for the given support and REDUCCIÓN DE LAS EMISIONES DE CO2 EN LA PRODUCCIÓN DE AGUA CALIENTE A ALTA TEMPERATURA A PARTIR DE LA RECUPERACIÓN DE CALOR RESIDUAL MEDIANTE EL USO DE UNA BOMBA DE CALOR with the reference SP20180039.