UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

ICM system validated on 10MW Kaplan and 25MW Francis prototype turbines

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
The Injection of Continuous Momentum (ICM) systems aims at reducing pressure fluctuations, and associated negative effects on shaft line dynamics, by introducing angular momentum to the flow field. The validation of the ICM took place on two prototype turbines. 1) A Kaplan unit, Porjus U9, at 10MW and 2) A Francis unit, Svorka, at 25MW. The results confirm the potential of the ICM technology to extend the operation of hydraulic turbines.
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

Report of the SHM systems validated on a model turbine

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
This report aims to summarize the different steps carried out to design, implement and test an optimized version of the Structural Health Monitoring (SHM) system for evaluating the turbine model test rig condition and performance during steady and transient operation conditions located at the Vattenfall R&D facility in Älvkarleby (Sweden). Additionally, a description of the results obtained are presented and they are analyzed based on the different measurement campaigns carried out with the Porjus U9 reduced scale Kaplan turbine runner. The document comprises a section outlining the condition monitoring approach used in the measuring campaigns, where the set-up in terms of types and positions of the physical variables measured have been optimized to end up computing the final reliable indicators. These indicators will be used to feed the controller that actuates with the appropriate active flow control techniques. The SHM is implemented in the turbine model in real-time using a CompactRIO (cRIO) hardware, where all the physical variables are measured using different sensors connected to their corresponding acquisition modules. Moreover, this SHM permits to visualize the temporal evolution of the signals and to analyze them in real time by computing the signal frequency content and updating the levels of the computed indicators to track their trends. Moreover, the SHM system has been used to evaluate the validity and effectiveness of the proposed IPM and ICM systems, and of the controller implemented on the model test rig to reduce the induced vibrations by the Rotating Vortex Rope (RVR) and the stochastic flow phenomena for a series of different off-design steady and transient operating conditions such as ramping of load
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

AFC system experimentally investigated on a 10 MW Kaplan prototype turbine and a 200 MW Francis prototype turbine

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
The Active Flow Control (AFC) system is a multifaceted integration of distinct subsystems, including the Injection of Pulsating Momentum (IPM), Injection of Continuous Momentum (ICM), Structural Health Monitoring System (SHM), and the controller. Initially developed independently on smaller scales across diverse institutions, the project progressed through the upscaling of these subsystems and their subsequent integration. This document presents experimental measurements conducted on prototypes specifically focusing on the IPM, ICM, and SHM subsystems. Although the controller developed and tested at smaller scales was ready to be tested at the prototype scale, it was not feasible to run the complete AFC system due to severe time constraints arising from turbine-related issues and safety requirements. Nevertheless, the results obtained from the tested subsystems are encouraging, underscoring the potential of the AFC system despite the aforementioned limitations.
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

Report of the SHM system tested, optimised and coupled with the controller in the simple structure at the laboratory

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
This report aims to summarize the different tasks performed at laboratory level on a simple structure, which can be rotated and submerged in water, in order to design, build and test a Structural Health Monitoring (SHM) system for evaluating the turbine condition and performance during steady and transient conditions. The document starts outlining the condition monitoring approach to be used during the different test campaigns and it describes the corresponding implementation in a real-time cRIO environment. The document continues presenting a summary of the different test campaigns performed to check traditional sensors and new sensors based on fiber-optics technology together with the optimal signal processing tools to assess the structure response. Furthermore, the tasks carried out to develop a controller for vibration reduction are also presented and discussed. And finally, the last section describes the ongoing effort to extend the current methodology towards an actual health monitoring approach based on fatigue studies., This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No 814958
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

AFC system validated on a model turbine

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
The Active Flow Control (AFC) system is composed of various subsystems, encompassing the Injection of Pulsating Momentum (IPM), Injection of Continuous Momentum (ICM), Structural Health Monitoring System (SHM), and the controller. The process of developing these subsystems and integrating them has been executed on a turbine model. The obtained and presented results effectively showcase the capabilities of the developed concept.
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

Report of the SHM system validated on 10 MW Kaplan prototype and 210 MW Francis prototype turbine

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
This report aims to summarize the design, development, testing and evaluation of the Structural Health Monitoring (SHM) system performance in combination with the IPM and ICM systems to reduce the induced damage during operation at steady off-design and transient conditions in actual Kaplan and Francis prototype turbines of different sizes. With the experience gathered from the measurement campaign at the reduced scale model turbine and the characterization of the structures dynamic responses based on the numerical simulations and experimental modal tests, a complete SHM system has firstly been tested and optimized in the 10 MW Porjus Kaplan turbine and then a series of more compact, reliable and affordable versions have been designed for their use in prototypes under actual exploitation conditions such as the 210 MW Oksla Francis turbine and the 25 MW Svorka Francis turbine. The document starts with a section outlining the software used for the implementation of the data acquisition, together with a description of the instrumentation and hardware used in the measuring campaigns at the three different prototypes (Porjus, Oksla and Svorka) to obtain the most reliable indicators of the turbines’ structural health. Then, the measuring campaigns at each turbine prototype are explained in detail and the main results are summarized which demonstrate the capability of the SHM systems to assess in real-time the effects of the Rotating Vortex Rope in their structure response and the capacity of the IPM and ICM combined with a control strategy to achieve the optimal conditions for the maximum damage reduction.
UPCommons. Portal del coneixement obert de la UPC
Publicación Estudio, informe, memoria (Report)

Report of the dynamic responses of the model and prototype turbines

  • Escaler Puigoriol, Francesc Xavier|||0000-0002-9374-7749
This report aims to present the different numerical simulations of the model and prototype turbines which were selected to install the AFC4Hydro system, as well as the experimental modal analysis performed to validate those numerical models. In the first section of the document, the geometry of the Porjus U9 reduced scale turbine model is presented. Secondly, the results of a numerical modal analysis of the entire runner and of a single blade are described considering the surrounding water as an infinite domain. Furthermore, the whole shaft line up to the generator has been simulated and validated experimentally in the test rig of Älvkarleby, quantifying the frequencies and damping ratios of the first 4 modes in air and water. Finally, modal analyses of the modified draft tube cone to accommodate the IPM and ICM systems have been performed to avoid the risk of resonances. The following section is devoted to present the numerical results of the Porjus U9 prototype model, which incorporates the different structural elements of the prototype geometry. Firstly, modal analyses of different subcomponents of the turbine have been simulated individually, such as a runner blade or the entire runner. For the shaft line, the periodic rotating forces acting on the runner and the orbits on the generator have also been calculated through a harmonic analysis. Additionally, a validation of the numerical modal analysis of the shaft line has been performed comparing the obtained results with the ones from the experimental modal analysis performed in the full-scale Porjus prototype using the rowing hammer technique. With the validated model, the dynamic response of the shaft line has been computed considering the oscillating forces induced in the runner blades by the hydrodynamic loads of the rotating vortex rope excitation. Finally, modal analyses of the new draft tube cone to accommodate the IPM and ICM systems have also been performed to ensure there is no risk of resonances. Considering the forces and moments induced by the AFC systems on the draft tube cone holes, a structural analysis has also been performed to ensure the integrity of the proposed modifications to allocate the control mechanisms. The electrical, electromagnetic and mechanical performance of the synchronous generator of the Porjus U9 prototype have also been assessed using the ANSYS Maxwell tool RMxprt. The generator has been studied in its flawless operation and compared with the rotor’s non-ideal movement. With these studies, the consequences of the rotor eccentricities have been analyzed to assess if the irregularities in the rotor movement could be observed through any sensor located in a particular position of the generator. With these simulations it has been found that, even though the electrical variables are not significantly altered by the eccentricity, other variables such as the air gap flux density, stator tooth forces and torque waveforms are affected by the eccentricity. In the last section of the document, a numerical model with a geometry similar to the Oksla prototype is presented. With that similar but not exactly equal runner, a numerical modal analysis has been performed and compared with an experimental modal analysis of the real Oksla runner in air.