Advanced Biomedical Optic Systems for Vision Testing and Retinal Imaging

RYC2021-033355-I

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Desarrollar, Atraer y Retener Talento
Subprograma Subprograma Estatal de Incorporación
Convocatoria Ramón y Cajal
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Simulation of daily soft multifocal contact lenses using SimVis Gekko: from in-vitro and computational characterization to clinical validation

  • Esteban-Ibañez, Eduardo
  • Montagud-Martínez, Diego
  • Sawides, Lucie
  • Zaytouny, Amal
  • de Castro, Alberto
  • Sisó-Fuertes, Irene
  • Barcala, Xoana
  • Piñero, David P.
  • Furlan, Walter D.
  • Dorronsoro, Carlos
  • Gambra, Enrique
  • Piñero, David P.|||/items/02d2ffcc-a108-4e8d-ad21-df3b3fc92a22
Multifocal contact lenses (MCLs) are one of the solutions to correct presbyopia, but their adoption is not widespread. To address this situation, visual simulators can be used to refine the adaptation process. This study aims to obtain accurate simulations for a visual simulator (SimVis Gekko; 2EyesVision) of daily soft MCL designs from four manufacturers. In-vitro characterization of these MCLs—several powers and additions- was obtained using NIMO TR-1504. From the averaged relative power profiles across powers, phase maps were reconstructed and the Through-Focus Visual Strehl metric was calculated for each MCL design. The SimVis Gekko simulation corresponding to each MCL design was obtained computationally and bench-validated. Finally, the MCL simulations were clinically validated involving presbyopic patients. The clinical validation results show a good agreement between the SimVis Gekko simulations and the real MCLs for through-focus visual acuity (TF-VA) curves and VA at three real distances. All MCL designs showed a partial correlation higher than 0.90 and a Root Mean Square Error below 0.07 logMAR between the TF-VA of simulations and Real MCLs across subjects. The validity of the simulation approach using SimVis Gekko and in-vitro measurements was confirmed in this study, opening the possibility to accelerate the adaptation of MCLs.