Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Silk-Based Enzymatic Biosensor with a superior stability for Long-Term Electrochemical Glucose Monitoring in Cell Cultures

  • Moreno Diaz, Alexander
  • Jiménez-Jorquera, Cecilia
  • Muñoz Berbel, Xavier
  • Vila Flores, Biel
  • Giménez-Gómez, Pablo
  • Requera, Cristina
  • Aznar, Salvador
  • Rodríguez, Rosalía
Partial or total redistribution of the data without written approval by the copyright owners is not permitted. The dataset is provided 'as is' although it has gone through thorough analysis, it is possible to find inconsistencies, if you find it please report it to the authors, Raw data obtained with glucose sensors design, optimization, characterization and validation for implementing the monitoring in cell cultures., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Experimental data → xlsx, txt; Device’s design → png; Set up, devices → jpg, mp4, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Silk Fibroin Functionalized ISFETs with ionophore for Long-Term Cl- Monitoring of Cell Cultures

  • Moreno Diaz, Alexander
  • Jiménez-Jorquera, Cecilia
  • Dominguez Horna, Carlos
  • Muñoz Berbel, Xavier
  • Aznar, Salvador
  • Ríos Gallardo, Juan Manuel
Raw data obtained with Cl- sensors design, optimization and characterization. This sensor aim is monitoring Cl- in high biofouling samples, as in cell culture media., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Experimental data → xlsx, txt; Device’s design → png; Set up, devices → jpg, mp4, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Silk Fibroin Functionalised Isfets with Enhanced Stability for Long-Term Ph Monitoring of Cell Cultures, Moreno Diaz, A.; Urbano-Gámez, J.D.; Pérez-Montero, M.; Rodríguez-Rodríguez, R.; Aznar-Cervantes, S.D.; Perdigones, F.; Quero, J.M.; Horna, C.D.; Jiménez-Jorquera, C.; Muñoz-Berbel, X., Silk Fibroin Functionalised Isfets with Enhanced Stability for Long-Term Ph Monitoring of Cell Cultures, Social Science Research Network, 2023

  • Moreno Diaz, Alexander
  • Urbano-Gámez, Jesus
  • Pérez-Montero, Marta
  • Rodríguez-Rodríguez, Rosalia
  • Aznar-Cervantes, Salvador
  • Perdigones, Francisco
  • Manuel Quero, José
  • Domínguez Horna, Carlos
  • Jiménez-Jorquera, Cecilia
  • Muñoz Berbel, Xavier
Silk-fibroin is a biomaterial with high thermal and chemical stability, mechanical strength, biocompatibility, wettability and filtration capacity. These properties are here exploited in the development of miniaturised long-life pH sensors implemented in microfluidic chambers for long-term cell culture monitoring. Silk fibroin is crystallised on the gate of silicon nitride ion- selective-field-effect-transistors (ISFETs), producing silk films of 30±14 μm. The silk-modified ISFETs exhibit similar responses to pH than bare ISFETs in terms of sensitivity (51±2 mV/pH vs. 51±4 mV/pH) and precision (both >99% vs. glass-membrane pH meters). Main advantages of silk modification reside on the sensor drift and biofouling. Hence, silk ISFETs present smaller signal variations associated to drift and to molecular adsorption, the latter reduced 10 times thanks to the filtering capacity of the film. After implementation in cell culture chambers, silk-modified ISFETs are able to continuously monitor the culture pH for more than 3 days without the need for recalibration steps. Due to their simplicity of operation, durability, excellent analytical performance and small size, these sensors may be a first choice in applications where precise pH determination is required in small sample volumes, e.g. cell culture analysis, clinical diagnostics or sweat monitoring., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Optic sensor for adipose cells monitoring using living photonics

  • Moreno Diaz, Alexander
  • Jiménez-Jorquera, Cecilia
  • Muñoz Berbel, Xavier
  • Vera, Aina
  • Giménez-Gómez, Pablo
  • Requena, Cristina
  • Aznar-Cervantes, Salvador
  • Rodríguez-Rodríguez, Rosalia
Raw data obtained by the optic sensor design, optimization, characterization and validation. This sensor aim is to monitor the adipocyte differentiation from pre-adipocyte to white adipocyte, This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for 3D microelectrode array with alginate/graphite electrodes for monitoring retina cells with light stimulation

  • Moreno Diaz, Alexander
  • Jiménez-Jorquera, Cecilia
  • Domínguez Horna, Carlos
  • Muñoz Berbel, Xavier
  • Aznar-Cervantes, Salvador
  • Merlos Domingo, Ángel
  • Perdigones, Francisco
  • Quero, Jose Manuel
Raw data obtained by the 3D microelectrode array electrodeposition, optimization and characterization. This MEA aim is to monitor retina cells under discontinuous light stimulation., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Replication data for Microelectrode array with heater and temperature sensor for monitoring retina cells with light stimulation

  • Moreno Diaz, Alexander
  • Jiménez-Jorquera, Cecilia
  • Domínguez Horna, Carlos
  • Muñoz Berbel, Xavier
  • Aznar-Cervantes, Salvador
  • Merlos Domingo, Ángel
  • Perdigones, Francisco
  • Quero, Jose Manuel
Raw data obtained by the microelectrode array design, optimization and characterization. This MEA aim is to monitor retina cells under discontinuous light stimulation., This work was funded by the Spanish Ministry of Science and Innovation, MICINN− State Research Agency −AEI− (PID2021-127653NB-C21), the MICINN FPI program (PRE2019−088338) and European Commission ERDF/FEDER Operational Programme of Murcia (2021-2027); Project No. 50463. Project name: Integración de biosensores, matrices de microelectrodos 3D y circuitos fotónicos con tecnología compatible CMOS Project number: PID2021-127653NB-C1, Peer reviewed