DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación
Set de datos (Dataset)
[Dataset] Method optimization for a simultaneous determination of neonicotinoid, carbamate/thiocarbamate, triazole, organophosphate and pyrethroid pesticides and their metabolites in urine using UPLC-MS/MS, Data and R scripts for the manuscript on Pesticides Method Validation
Data and R scripts for the manuscript on Pesticides Method Validation
There are 4 folders with the following contents:
LD_Calculations: Contains data and R scripts for the calculation of limits of detection. The R script creates a csv file with the LDs.
Precision: Contains data and R scripts for the calculation of intra-day and inter-day precision. The R script creates two csv files with intra-day and inter-day CVs, and graphical representation. <<<<<<< HEAD
Linearity_Recovery: Contains data and R scripts for the calculation of R2 as a measure of linearity, as well as graphical visualization of the calibration curves, and calculation of recoveries from QCH and QCL preparations.
Matrix_Effects: Contains data, R scripts and graphical representation for the evaluation of matrix effects and recoveries from synthetic/real urine samples. The Figure produced is presented at the manuscript., An accurate and sensitive method for the determination of a total of 23 pesticides and their metabolites in human urine has been optimised. The methodology is based on a previously published method based on solid-phase extraction with methanol and acetone followed by ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) in the selected reaction mode (SRM) with both positive and negative electrospray ionization (ESI+/-). The detection settings of the previous method, which allowed to determine the metabolites from 6 organophosphate and 2 pyrethroid pesticides, were optimised in order to include further pesticide groups, such as 11 neonicotinoids, 3 carbamates/thiocarbamates and 2 triazoles. The 5-windows method enduring 22 min was optimized with acceptable results in relation to accuracy (recoveries >75 %), precision (coefficients of variation <26 %) and linearity (R2> 0.9915). The limits of detection ranged between 0.012 ng/mL and 0.058 ng/mL. Samples from the German External Quality Assessment Scheme (G-EQUAS) encompassing 2 pyrethroids, 2 organophosphate and one neonicotinoid (6-chloronicotinic acid, a common metabolite of imidacloprid and acetamiprid) were analysed, and the latter, included in this newest optimization, provided good reference results. The method is optimal as a human biomonitoring tool for health risk assessment in large population surveys., This research has receive financial support from the European Union Projects EDCMET (H2020-HEALTH/0490-825762), NEMESIS (H2020-HEALTH/101137405) and PARC (HEALTH-2021-ENVHLTH-3:101057014) and the Spanish Ministry of Science, Innovation and Universities (CNS2023-143649). Mercè Garí acknowledges the support from the office of the Secretary of Universities and Research and the Ministry of Research and Universities of the Government of Catalonia through the Beatriu de Pinós Programme (Grant No. 2021BP00152). Mercè Garí is currently supported by a fellowship from the Fundación General CSIC's ComFuturo programme which has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie grant agreement No. 101034263. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Authors are grateful to R. Chaler and A. García Barrera for their support at the Mass Spectrometry Laboratory of IDAEA-CSIC., Peer reviewed
Proyecto:
EC / H2020 101034263
,
EC / H2020 825762
,
EC / H2020 101137405