Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Persistent Luminescence Analysis in the Frequency domain

  • Romero Aguilar, Manuel
  • Castaing, Victor
  • Rytz, Daniel
  • Lozano, Gabriel
  • Míguez, Hernán
File List: - Fig2_ab.txt : Temperature dependent frequency spectra of SC1 measured for 1.92mW/mm2 excitation density: Frequency in Hz (column 1), Hr (column 2) and Hi (column 3) at 25C; Hr (column 4) and Hi (column 5) at 30C; Hr (column 6) and Hi (column 7) at 35C; Hr (column 8) and Hi (column 9) at 40C. - Fig2_cd.txt : Excitation density dependent frequency spectra of SC1 measured at 25C: Frequency in Hz (column 1), Hr (column 2) and Hi (column 3) for 1.92mW/mm2; Hr (column 4) and Hi (column 5) for 203uW/mm2; Hr (column 6) and Hi (column 7) for 203uW/mm2. - Fig3.txt : Low excitation density frequency spectra for the Powder, SC2 and SC3 at 25C: Frequency in Hz (column 1), Hr (column 2) and Hi (column 3) for the Powder; Hr (column 4) and Hi (column 5) for SC2; Hr (column 6) and Hi (column 7) for SC3., Frequency-domain techniques offer a powerful means to disentangle overlapping physical processes with distinct characteristic timescales—yet remain underexplored in the context of complex photoluminescent materials. Here, we apply frequency-domain analysis to persistent luminescence (PersL) materials, which exhibit long-lasting emission following excitation due to charge trapping and detrapping processes spanning wide temporal ranges. Using SrAl₂O₄:Eu²⁺,Dy³⁺ (SAO:Eu,Dy) as a model system, we develop a general framework for frequency-domain characterization of PersL and report, for the first time, a direct measurement of the trapping rate in such a material. Our approach also enables quantitative assessment of trapping probability, efficiency, and overall PersL performance. This work opens a new pathway for rational optimization of afterglow materials based on mechanistic insights beyond conventional time-domain approaches., This project has received funding from the BBVA Foundation Leonardo Grant for Physics Researchers 2023, and from MCIN/AEI/10.13039/501100011033 by European Union NextGeneration EU/PRTR under grant EUR2023-143467 and PID2024-161708OB-I00. M.R. acknowledges the grant FPU23/01435 funded by MCIN/AEI/10.13039/501100011033. VC acknowledges Junta de Andalucía for financial support through a postdoctoral contract (POSTDOC_21_00694)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Refractive index and strain modulation tailor the afterglow of nanocomposite films [Dataset]

  • Castaing, Victor
  • Romero Aguilar, Manuel
  • Drion, Théophile
  • Fernández-Carrión, Alberto J.
  • Lozano, Gabriel
  • Míguez, Hernán
Tailoring the unique delayed and long-lasting luminescence of persistent phosphors is crucial for their application in anti-counterfeiting, data storage, imaging displays, and AC-driven lighting. We introduce a novel strategy to achieve this by modifying the refractive index of persistent phosphor transparent coatings. Specifically, we developed ZnGa2O4:Cr3+/SiO2 nanocomposite films with tunable refractive indices from 1.45 to 1.7. This tunability allowed us to precisely control the Cr3+ radiative decay rate, resulting in a substantial 1.7-fold increase in both luminescence and afterglow brightness. Furthermore, our approach uniquely influences the intrinsic charging rate of the phosphor, a mechanism attributed to the strain induced on the ZnGa2O4:Cr3+ nanocrystals by the presence of SiO2. This work demonstrates an unprecedent ability to manipulate the afterglow kinetics without altering the material composition, opening new avenues for designing and optimizing persistent luminescence materials., This project has received funding from the BBVA Foundation Leonardo Grant for Physics Researchers 2023, and by the Spanish Ministry of Science, Innovation and Universities under Grant EUR2023-143467 funded by MICIU/AEI/ 10.13039/501100011033 and by the European Union NextGenerationEU/PRTR, and Grant PID2024-161708OB-I00 funded by MICIU/AEI/ 10.13039/501100011033. V.C. acknowledges Junta de Andalucía for financial support (POSTDOC_21_00694). MR acknowledges the grant FPU23/01435 funded by MCIN/AEI/10.13039/501100011033., Peer reviewed, File List: - Fig1b_ParticleDiameter.txt : Number of particles (column 1), ZnGa2O4:Cr3+ particle diameter (column 2) and SiO2 particle diameter (column 3). - Fig1i_XRD.txt : 2 theta (º, column 1), normalized XRD reflection intensity of 100:0 1000 °C (column 2), 100:0 800 °C (column 3), 50:50 1000 °C (column 4), 50:50 800 °C (column 5). - Fig1j_Strain.txt : SiO2 content (%, column 1), Strain 404 of 1000 °C samples (column 2), Strain 404 of 800 °C samples (column 3), cubic lattice parameter relative variation of 1000 °C samples (column 4), cubic lattice parameter relative variation of 800 °C samples (column 5). - Fig2a_RefractiveIndex_GradMZGO.txt : SiO2 content (%, column 1), effective refractive index of 1000 °C sample (column 2), effective refractive index of 800 °C sample (column 3), calculated product of the radiative decay rate and the quantity of ZGO for samples calcined at 1000 °C (column 4), measured product of the radiative decay rate and the quantity of ZGO for samples calcined at 1000 °C (column 5) and calculated product of the radiative decay rate and the quantity of ZGO for samples calcined at 800 °C (column 6). - Fig2c_Lum.txt : Wavelength (nm, column 1), normalized Lum intensity of reference 100:0 1000 °C sample (column 2), normalized Lum intensity of 90:10 1000 °C sample (column 3), normalized Lum intensity of 100:0 800 °C sample (column 4), normalized Lum intensity of 90:10 800 °C sample (column 5). - Fig2d_LumEnhancement.txt : SiO2 content (%, column 1), Lum enhancement of 1000 °C samples (column 2), standard deviation of Lum enhancement of 1000 °C samples (column 3) and Lum enhancement of 800 °C samples (column 4). - Fig3a_PersL.txt : Wavelength (nm, column 1), normalized PersL intensity of reference 100:0 1000 °C sample (column 2), normalized PersL intensity of 90:10 1000 °C sample (column 3), normalized PersL intensity of 100:0 800 °C sample (column 4), normalized PersL intensity of 90:10 800 °C sample (column 5). - Fig3b_PersLEnhancement.txt : SiO2 content (%, column 1), PersL enhancement of 1000 °C samples (column 2), standard deviation of PersL enhancement of 1000 °C samples (column 3), PersL enhancement of 800 °C samples (column 4), standard deviation of PersL enhancement of 800 °C samples (column 5). - Fig4b_Kinetics_800°C.txt : Time (s, column 1), measured normalized PersL intensity of 100:0 800 °C sample (column 2), fitted normalized PersL intensity of 100:0 800 °C sample (column 3), measured normalized PersL intensity of 90:10 800 °C sample (column 4), fitted normalized PersL intensity of 90:10 800 °C sample (column 5), measured normalized PersL intensity of 80:20 800 °C sample (column 6), fitted normalized PersL intensity of 80:20 800 °C sample (column 7), measured normalized PersL intensity of 70:30 800 °C sample (column 8) and fitted normalized PersL intensity of 70:30 800 °C sample (column 9). - Fig4c_Kinetics_1000°C.txt : Time (s, column 1), measured normalized PersL intensity of 100:0 1000 °C sample (column 2), fitted normalized PersL intensity of 100:0 1000 °C sample (column 3), measured normalized PersL intensity of 90:10 1000 °C sample (column 4), fitted normalized PersL intensity of 90:10 1000 °C sample (column 5), measured normalized PersL intensity of 80:20 1000 °C sample (column 6), fitted normalized PersL intensity of 80:20 1000 °C sample (column 7), measured normalized PersL intensity of 70:30 1000 °C sample (column 8) and fitted normalized PersL intensity of 70:30 1000 °C sample (column 9). - Fig4d_BrightnessFactor_TrappingStrength_800°C.txt : SiO2 content (%, column 1), trapping strength parameter omega of 800 °C samples (column 2), brightness factor MZGO*Grad/Gtot of 800 °C samples (column 3) and standard deviation of brightness factor MZGO*Grad/Gtot of 800 °C samples (column 4). - Fig4e_BrightnessFactor_TrappingStrength_1000°C.txt : SiO2 content (%, column 1), trapping strength parameter omega of 1000 °C samples (column 2), standard deviation of trapping strength parameter omega of 1000 °C samples (column 3), brightness factor MZGO*Grad/Gtot of 1000 °C samples (column 4) and standard deviation of brightness factor MZGO*Grad/Gtot of 1000 °C samples (column 5). - Fig_S3a.txt : Ellipsometry spectra and fitting of ZGO:Cr film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_S3b.txt : Ellipsometry spectra and fittings of 90:10 composite film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_S3c.txt : Ellipsometry spectra and fittings of 80:20 composite film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_S3d.txt : Ellipsometry spectra and fittings of 70:30 composite film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_S3e.txt : Ellipsometry spectra and fittings of 60:40 composite film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_S3f.txt : Ellipsometry spectra and fittings of 50:50 composite film annealed at 1000 °C. Measurements were performed for the following incident angles: 50º,55º,60º,65º,70º. Wavelength in nm (column 1), delta in º (columns 2-6), psi in º (columns 7-11), fitted delta in º (columns 12-16), fitted psi in º (columns 17-21). - Fig_4a.txt : Transmission and reflection spectra and fittings of ZGO:Cr film annealed at 800 °C. Measurements were performed for the following incident angles: 6º,30º,50º. Wavelength in nm (column 1), reglectance R (columns 2-4), transmittance (columns 5-7), fitted reflectance (columns 8-10), fitted transmittance (columns 11-13). - Fig_4b.txt : Transmission and reflection spectra and fittings of 80:20 composite film annealed at 800 °C. Measurements were performed for the following incident angles: 6º,30º,50º. Wavelength in nm (column 1), reglectance R (columns 2-4), transmittance (columns 5-7), fitted reflectance (columns 8-10), fitted transmittance (columns 11-13). - Fig_4c.txt : Transmission and reflection spectra and fittings of 50:50 composite film annealed at 800 °C. Measurements were performed for the following incident angles: 6º,30º,50º. Wavelength in nm (column 1), reglectance R (columns 2-4), transmittance (columns 5-7), fitted reflectance (columns 8-10), fitted transmittance (columns 11-13).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Unraveling Thermal Interactions in Lanthanide-Doped Phosphors: A Frequency-Domain Analysis Approach [Dataset]

  • Romero Aguilar, Manuel
  • Castaing, Victor
  • Rytz, Daniel
  • Lozano, Gabriel
  • Míguez, Hernán
Ensuring the thermal reliability of luminescent materials is a key requirement for next-generation lighting, display, and sensing technologies. The intricate interplay of thermal crossover and thermal ionization in lanthanide-doped phosphors often obscures their individual contributions. We present a frequency-domain photoluminescence analysis that disentangles these competing mechanisms. Using single crystals of SrAl₂O₄:Eu²⁺,Dy³⁺ (SAO:Eu,Dy) and (Gd₀.₃₃Y₀.₆₇)₃Al₂.₄Ga₂.₆O₁₂:Ce3+,Cr3+ (GYAGG:Ce,Cr) as model systems, we extract temperature-dependent trapping efficiencies and decay rates by analyzing the phase and amplitude response of luminescence under modulated excitation. Our approach reveals distinct signatures of thermal ionization and enables the direct quantification of ionization barriers and crossover rates. We demonstrate that SAO:Eu,Dy exhibits dominant trapping behavior with high ionization efficiency, while GYAGG:Ce,Cr shows significant competition between ionization and crossover. This method provides a powerful framework for resolving overlapping quenching pathways and offers new insights for the design of thermally robust luminescent materials., This project has received funding from the BBVA Foundation Leonardo Grant for Physics Researchers 2023, and from the Spanish Ministry of Science and Innovation under grant EUR2023-143467 funded by MCIN/AEI/10.13039/501100011033 and by European Union NextGeneration EU/PRTR, and PID2024-161708OB-I00 funded by MCIN/AEI/10.13039/501100011033 and ERDF/EU. MR acknowledges the grant FPU23/01435 funded by MCIN/AEI/10.13039/501100011033. V.C. acknowledges Junta de Andalucía for financial support (POSTDOC_21_00694)., - Fig1b_emi.txt : PL spectra of SAO:Eu,Dy at 200K: Wavelength in nm (column 1), intensity in detector counts (column 2). - Fig1b_exc.txt : Excitation spectra of SAO:Eu,Dy at 200K: Wavelength in nm (column 1), intensity in detector counts (column 2). - Fig1c_emi.txt : PL spectra of GYAGG:Ce,Cr at 200K: Wavelength in nm (column 1), intensity in detector counts (column 2). - Fig1c_exc.txt : Excitation spectra of GYAGG:Ce,Cr at 200K: Wavelength in nm (column 1), intensity in detector counts (column 2). - Fig1d.txt : PL quenching curves of SAO:Eu,Dy: Temperature in K (column 1), intensity in detector counts for an excitation density of 4mW/cm2 (column 2), intensity in detector counts for an excitation density of 0.04mW/cm2 (column 3). - Fig1e.txt : PL quenching curves of GYAGG:Ce,Cr: Temperature in K (column 1), intensity in detector counts for an excitation density of 4mW/cm2 (column 2), intensity in detector counts for an excitation density of 0.04mW/cm2 (column 3). - Fig2a.txt : Real part of the transfer function (Hr) as a function of temperature for SAO:Eu,Dy: Data is given in a matrix form with the first column corresponding to frequency in Hz and the first row corresponding to temperature in K. - Fig2b.txt : Imaginary part of the transfer function (Hi) as a function of temperature for SAO:Eu,Dy: Data is given in a matrix form with the first column corresponding to frequency in Hz and the first row corresponding to temperature in K. - Fig2d.txt : Real part of the transfer function (Hr) as a function of temperature for GYAGG:Ce,Cr: Data is given in a matrix form with the first column corresponding to frequency in Hz and the first row corresponding to temperature in K. - Fig2e.txt : Imaginary part of the transfer function (Hi) as a function of temperature for GYAGG:Ce,Cr: Data is given in a matrix form with the first column corresponding to frequency in Hz and the first row corresponding to temperature in K. - Fig3a_SAO.txt : Trapping efficiency as a function of temperature for SAO:Eu,Dy: Temperature in K (column 1), trapping efficiency (column 2). - Fig3a_GYAGG.txt : Trapping efficiency as a function of temperature for GYAGG:Ce,Cr: Temperature in K (column 1), trapping efficiency (column 2). - Fig3b_SAO.txt : Trapping rate and total decay rate as a function of temperature for SAO:Eu,Dy: Temperature in K (column 1), trapping rate in Hz (column 2), total decay rate in Hz (column 3). - Fig3b_GYAGG.txt : Trapping rate and total decay rate as a function of temperature for GYAGG:Ce,Cr: Temperature in K (column 1), trapping rate in Hz (column 2), total decay rate in Hz (column 3)., Peer reviewed