Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Docta Complutense
Datos de investigación Set de datos (Dataset)

Data: In vitro corrosion-assisted cracking of AZ31B Mg alloy with a hybrid PEO+MWCNTs/PCL coating

  • Daavari, Morteza
  • Conde, Ana
  • Atapour, Masoud
  • HosseinpourRokni, Mohsen
  • Mora Sánchez, Hugo
  • Mohedano Sánchez, Marta
  • Matykina, Endzhe
  • Arrabal Durán, Raúl
The effects of multi-walled carbon nanotubes (MWCNTs) incorporation and polycaprolactone (PCL) post-treatment on the environmental-assisted cracking behaviour of a plasma electrolytic oxidation (PEO) coated AZ31B Mg alloy were elucidated in this study. Slow strain rate tensile (SSRT) experiments were carried out in simulated body fluid (SBF) for the bare material and different coating systems with and without MWCNTs and PCL overlay. Electrochemical impedance spectroscopy (EIS) and microscopic examinations (SEM and optical) were also conducted to reveal the role of corrosion on the mechanical response. In spite of the significant positive influence of the PEO coatings (with and without MWCNTs) on the bio-electrochemical behaviour of the AZ31B alloy, the environmental-assisted cracking performance was only marginally improved. Furthermore, PEO+MWCNTs/PCL coating system increased the fracture strain of the specimens by 7% compared to the uncoated specimens. Based on the SEM and optical micrographs, hydrogen embrittlement was suggested as the main cause of failure of the coated specimens under the in vitro slow strain rate test conditions.
Docta Complutense
Datos de investigación Set de datos (Dataset)

Data: Flash plasma electrolytic oxidation and electrochemical behaviour in physiological media of additive manufacturing Ti6Al4V alloy

  • Mora Sánchez, Hugo
  • Ramos, Carolina
  • Mohedano Sánchez, Marta
  • Torres, Belén
  • Arrabal Durán, Raúl
  • Matykina, Endzhe
The objective of this work is to understand the plasma electrolytic oxidation (PEO) treatment and electrochemical behaviour of a Ti6Al4V alloy manufactured by a laser powder bed fusion additive manufacturing (AM) technique known as direct metal laser sintering (DMLS). Ca and P-containing coatings were produced with short time (<120 s) PEO treatments (also termed as Flash-PEO) obtaining 3–10 μm-thick coatings on both the AM alloy and a conventional counterpart. Subsequently, the electrochemical behaviour of the bare and treated alloys was assessed in a modified α-MEM solution via potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The fine α-lamellar microstructure of the AM alloy with small β-phase particles at the interlamellar spaces was seen to advance the onset of sparking promoting faster growth of PEO coating in comparison to the conventional alloy. Flash-PEO coatings enhanced the corrosion protection of both conventional and AM alloys, the thinnest (<3 μm) coatings providing up to three times greater protection. AM Ti6Al4V was found to be susceptible to localized crevice corrosion which could be assigned to the high grain boundary density. Flash-PEO treatments, even as short as 35 s, were sufficient to successfully prevent it.
Docta Complutense
Datos de investigación Set de datos (Dataset)

Data: Corrosion of additively manufactured Ti6Al4V alloy in saline and acidic media

  • Mora Sánchez, Hugo
  • Collado Vian, Miguel
  • Mohedano Sánchez, Marta
  • Arrabal Durán, Raúl
  • Matykina, Endzhe
The present work aims to provide corrosion performance data for an additively manufactured Ti6Al4V alloy in saline and polluted environments. The as-received additively manufactured material underwent heat treatment at 850 °C for 3 h to transform the acicular α’ microstructure into a lamellar α microstructure. Comparative corrosion assessments were conducted between the heat-treated substrates, the as-received condition, and a conventionally mill-annealed alloy. Potentiodynamic polarization experiments were carried out in saline (3.5 wt.% NaCl) and acid aqueous media ((NH4)2SO4 containing Harrison’s solution). The corrosion performance of additively manufactured substrates matched or surpassed that of the conventional alloy in Harrison’s solutions while remaining inferior in saline medium, despite forming a thicker passive film. Overall, the XY plane showed better corrosion performance, particularly after the elimination of the acicular α’ martensite by the applied heat treatment. The results also suggested that the presence of the coarse β phase was beneficial in 3.5 wt.% NaCl solution and detrimental in Harrison’s solutions, more so in acidified and fluorinated conditions.
Docta Complutense
Datos de investigación Set de datos (Dataset)

Data: Degradation rate control issues of PEO-coated wrought Mg0.5Zn0.2Ca alloy

  • Moreno Turiegano, Lara
  • Mohedano Sánchez, Marta
  • Arrabal Durán, Raúl
  • Matykina, Endzhe
Bioactive plasma electrolytic oxidation (PEO) coatings were developed on a wrought Mg0.5Zn0.2Ca alloy using a transparent electrolyte for easy maintenance and waste disposal, compared to a conventional suspension-based solution. Treatment times of 300, 600, and 900 s were evaluated for their effects on coating morphology, composition, and corrosion resistance. A short-time electrochemical impedance spectroscopy (EIS) screening was utilized to identify coatings with optimal corrosion protection. To assess the degradation rate and corrosion mechanisms, hydrogen evolution was monitored under pH-controlled quasi-in vivo conditions over extended immersion periods. Coating thickness increased by only 3% from 300 to 900 s of treatment (13 and 18 µm, respectively), with pore bands formed near the barrier layer at 900 s. The short-term EIS screening revealed that the coatings produced at 600 and 900 s were less protective and consistent than those at 300 s due to the presence of pore bands, which increased permeability. Hydrogen evolution measurements during 5 days of immersion at pH 7.4 indicated a tenfold higher degradation rate of the PEO-coated alloy compared to the bare substrate. Therefore, none of the PEO coatings provided effective corrosion protection after 24 h of immersion, which is attributed to crack formation at the PEO/corrosion products interface. This highlights the importance of crevices in the corrosion of Mg-Zn-Ca alloys. The presence of ZnO exacerbates the corrosion of magnesium in crevice areas.
Docta Complutense
Datos de investigación Set de datos (Dataset)

Data: Combination of electron beam surface structuring and plasma electrolytic oxidation for advanced surface modification of Ti6Al4V alloy

  • Mora Sánchez, Hugo
  • Pixner, Florian
  • Buzolin, Ricardo
  • Mohedano Sánchez, Marta
  • Arrabal Durán, Raúl
  • Warchomicka, Fernando
  • Matykina, Endzhe
The objective of this work is to study for the first time the combination of electron beam (EB) surface structuring and plasma electrolytic oxidation (PEO) with the aim of providing a multiscale topography and bioactive surface to the Ti6Al4V alloy for biomedical applications. Ca and P-containing coatings were produced via 45 s PEO treatments over multi-scale EB surface topographies. The coatings morphology and composition were characterized by a means of scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The effect on the previous EB topography was evaluated by means of a 3D optical profilometry and electrochemical response via potentiodynamic polarization tests. In general, the PEO process, morphology, composition and growth rate of the coatings were almost identical, irrespective of the topography treated. Minimal local differences were found in terms of morphology, and the growth rate were related to specific topographical features. Nevertheless, all the PEO-coated substrates presented essentially the same corrosion resistance. Electrochemical tests revealed a localized crevice corrosion susceptibility of all the bare EB topographies, which was successfully prevented after the PEO treatment.