Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

EDM-GNSS distance comparison at the EURO5000 calibration baseline: preliminary results

  • Wezka, Kinga
  • Próchniewicz, Dominik
  • Szpunar, Ryszard
  • Garrigues, Pascual
  • Walo, Janusz
  • Luján, Raquel
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
[EN] At the Pieniny Kippen Belt in Poland, the novel primary reference baseline EURO5000 is required as part of the European Research project GeoMetre to both validate refractivity-compensated EDM prototypes and investigate the metrological traceability of GNSS-based distances. Since the aimed uncertainty is 1 mm at 5 km (k=2), the design, construction, and validation must be carefully prepared to fulfil the high standards of the GeoMetre field campaigns which are planned to be carried out in May 2022. This contribution describes the main features of the EURO5000 and presents the results of the preliminary validation which includes a first comparison between the results obtained by using precise currently available EDMs as well as GNSS techniques following the standard GNSS geodetic processing algorithms, on the one hand, and the improved GNSS-Based Distance Meter (GBDM+) approach developed at UPV, on the other hand. The preliminary validation presented in this contribution also permits (1) to detect potential problems in the use of the baseline such as potential geodynamic problems, atmospheric refraction or multipath limitations, (2) to produce a set of reliable results, and (3) to pave the way for the final field comparisons between the novel EDMs and the GBDM+ approach. The result of this metrological experiment may significantly contribute to overcome the limitations of current high-precision deformation monitoring applications that require their scale to be consistent with the SI-metre within 0.1 ppm in several km., The project 18SIB01 GeoMetre has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme, funder ID: 10.13039/100014132. Raquel Luján acknowledges the funding from the Programa de Ayudas de Investigación y Desarrollo (PAID-01-20) de la Universitat Politècnica de València.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Capítulo o parte de un libro (BookPart)

Two multi-wavelength interferometers for large-scale surveying

  • Sauthoff, Anni
  • Köchert, Paul
  • Prellinger, Günther
  • Meyer, Tobias
  • Pilarski, Frank
  • Weinrich, Stephanie
  • Schmaljohann, Frank
  • Guillory, Joffray
  • Truong, Daniel
  • Silbermann, Jakob
  • Kallio, Ulla
  • Jokela, Jorma
  • Pollinger, Florian
[EN] Deformation monitoring requires the detection of smallest changes, always at the limits of technical feasibility. Trying to push these limits further, we have realised two terrestrial ranging instruments: a long-range 1D electro-optic distance meter and a 3D multilateration-capable sensor system of 50 m range. The former one is intended as primary standard for the calibration of geodetic instrumentation with low uncertainty to the SI definition of the metre. The latter one is intended for monitoring larger monuments like VLBI antennas. In this contribution, we describe the technical challenges and our solutions for such instrumentation. We use the two-colour method for inline refractive index compensation. As common optical source, we developed a versatile multi-wavelength generator based on two Nd:YAG lasers stabilised by a phase-locked loop realised by Field Programmable Gate Arrays (FPGA). The 1D interferometer uses custom-designed achromatic optics and a mechanical frame optimised for form stability under field conditions. The phase demodulation system allows for maximum range flexibility from several meters up to several kilometres. The base ranging unit of the 3D multilateration system adheres to a different demodulation technique, which allows a relatively simple interferometer head design. This approach requires a sophisticated source modulation scheme limiting the applicability to distances over 15 m up to approximately 50 m in our case., This project 18SIB01 GeoMetre has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme. We would like to thank P. Knigge, D. Fiala, M. Wedde, and M. Peglow for technical assistance.