Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Evaluación de restricciones de confort en controlador predictivo para la eficiencia energética, Comfort constraints evaluation in predictive controller for energy efficiency

  • Marchante, G.
  • Acosta, A.
  • González, A.I.
  • Zamarreño, J.M.
  • Álvarez, V.
[EN] This work reflects the results obtained, through simulation, from the study of the comfort constraints of a Model Predictive Controller (MPC), for the energy management of the centralized air conditioning system of a hotel installation. In order to achieve economic efficiency, the proposed controller is based on a prediction model of the behaviour of the energy consumption of the rooms from the hotel historical records. To satisfy the thermal comfort required by the occupants, a more complete comfort zone model is considered than the one used by (Acosta et al., 2016), in one of the constraints of the optimization problem. This allowed greater energy savings, this being the main contribution of this research. The simulations of the presented scenarios were performed with MATLAB®., [ES] En este trabajo se reflejan los resultados obtenidos, vía simulación, del estudio de las restricciones de confort de un controlador predictivo basado en modelo (MPC) no lineal, para la gestión energética del sistema centralizado de climatización de una instalación hotelera. Con el objetivo de lograr eficiencia económica, el controlador empleado utiliza un modelo de predicción del comportamiento del consumo energético de las habitaciones a partir de los registros históricos del hotel. Para satisfacer el confort térmico requerido por los ocupantes, se considera un modelo de zona de confort más completo, que el modelo utilizado por (Acosta et al., 2016), en una de las restricciones del problema de optimización. Esto permitió un mayor ahorro energético, siendo esta la principal contribución de esta investigación. Las simulaciones de los escenarios presentados fueron realizadas con MATLAB®., Este trabajo ha sido realizado gracias al apoyo del personal de la instalación hotelera que facilitó tanto las mediciones en las habitaciones como los registros históricos de consumo energético. El cuarto autor agradece el apoyo del Ministerio de Ciencia, Innovación y Universidades/FEDER a través del proyecto PGC2018-099312-B-C31; asimismo el apoyo de la Junta de Castilla y León y EU-FEDER (CLU 2017-09).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Integrated Process Re-Design with Operation in the Digital Era: Illustration through an Industrial Case Study

  • Marcos, María P.
  • de Prada, César
  • Pitarch, José Luis|||0000-0001-5356-6321
[EN] This work discusses what should be the desirable path and correct tools for the optimal re-design and operation of processes in the Industry 4.0 framework, as illustrated in a challenging case study corresponding to a complex network of evaporation plants in a viscose-fiber factory. The goal is to integrate optimal design, to improve the existing cooling systems, together with the optimal operation of the whole network, balancing the initial investment with the potentially achievable savings. A rigorous mathematical model for such optimization purpose has been built. The model explicitly considers different structural alternatives as a superstructure for the incorporation of new equipment into the network. The uncertainty associated to future operating conditions is also considered by using a two-stage stochastic formulation. Furthermore, the model is also the base from which a deterministic real-time optimization (RTO) builds upon to support the daily management of the future network operation. The RTO tool suggests the allocation of different products to evaporation plants, the distribution of the cooling water and the suitable number of heat pumps to switch on for optimal economic operation. Design and operation problems are formulated and solved via mixed-integer non-linear programming and the results have been tested with historical plant data., These results received funding from the Spanish MICIU with FEDER funds under project InCO4In (PGC2018-099312-B-C31) and by the regional government of Castilla y Leon and the EUFEDER (UIC 223 and CLU 2017-09). The first author thanks the European Social Fund and the "Consejeria de Educacion de la Junta de Castilla y Leon".