e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Micromotors Meet Collective (Bio)sensing: The Asset Behind the Assay

  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
Micromotors are microscale devices with enormous potential for analytical (bio)sensing due to autonomous motion capabilities in extremely small sample volumes or for guided detection in localized hard-to-reach areas. These unique features enable dynamic interactions with the analytes, offering considerable promise in microscale environments and opening new avenues for on-the-fly (bio)sensing strategies. By selecting and discussing the ideas and findings behind pioneering works, we offer our perspective on the current state of the art in the field of in vitro (bio)sensing approaches based on the micromotors classified according to their detection principle: motion-based, optical, and electrochemical sensing. We will also draw attention to current challenges and opportunities that have not yet been fully explored, in a landscape that is as exciting as it is changing., Agencia Estatal de Investigación, Junta de Comunidades de Castilla-La Mancha
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Building HKUST-1 metal organic frameworks on a board of Cu tubular micromotors with adaptive propulsive capabilities

  • Solano Rodríguez, Enrique
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
9 p., Herein we present one step simplified synthesis of tubular Cu micromotors based on Hong Kong University of Science and Technology (HKUST-1) metal organic frameworks (MOFs). Tubular Cu/Pt, Cu/Ni and Cu/Ni/Pt micromotors prepared via template electrodeposition are smartly used as nucleation spots for the synthesis of HKUST-1 MOFs by incubating with the specific ligand, benzene-1,3,5-tricarboxylic acid, without any harsh conditions. The inner engines impart the micromotors with adaptive propulsion mechanisms for future applications: magnetic, catalytic, and hybrid magnetic and catalytic modes, reaching speeds of up to 275 mu m s-1. Furthermore, stability studies reveal a delayed degradation of the HKUST-1 MOFs in the micromotors as compared with the free MOFs. The synthesis rationale and delayed stability of the HKUST-1 MOFs in water has been exploited for compound encapsulation and controlled release, as illustrated using fluorescein as the model molecule. This approach has unlocked a new range of possibilities for future applications, offering a promising platform for the development of functional micromotors with improved capabilities., Ministerio de Ciencia, Innovación y Universidades, Fondos Europeos de Desarrollo Regional, Unión Europea, Comunidad de Madrid, Junta de Comunidades de Castilla-La Mancha, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Dynamic intracatheter antibiotic delivery with ZIF-8 magnetic micromotors for ex vivo biofilms removal

  • Bujalance Fernández, Javier|||0000-0002-4582-296X
  • Gallego Manzano, Luis Manuel|||0009-0001-0955-2595
  • Arribi Vilela, Ana
  • López González, Laura
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
12 p., Herein, we describe the use of macroporous zeolitic imidazole framework-8 (ZIF-8) magnetic micromotors (ZIF-8@Fe3O4 MM) for ex vivo treatment of bacterial biofilms in patients' bladder catheters. Two antibiotics, ciprofloxacin (CIP) and tetracycline (TC), are loaded into the macroporous inner structure of the micromotors, which contain a magnetic core for targeted navigation to Escherichia coli (E. coli) biofilm-containing locations and pH-triggered release. The released antibiotic concentration after 24 h of treatment is 1.8 & micro;g/mL for CIP and 10.6 & micro;g/mL for TC. These values are 18 and 11 times higher than the estimated minimum inhibitory concentration, respectively, ensuring the micromotors' successful operation for biofilm destruction. The strategy was proven both in biofilm cultures emulated in 3D-printed microchannels and in bladder catheters from patients suffering from urinary tract infections. As such, 80% of the biofilm was removed in the catheters, even in the one highly infected after 50 days of treatment. The new strategy holds considerable promise for the treatment of bacterial infections associated with medical devices in the near future., Agencia Estatal de Investigación, Junta de Comunidades de Castilla-La Mancha, Fondo Europeo de Desarrollo Regional, Unión Europea, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Dynamic ACE2-functionalized magnetic micromotors for electrochemical protein S detection from SARS-CoV-2: toward diagnosis after virus mutation

  • Rodríguez Castillo, Alberto
  • Postigo, Tamara
  • Pérez García, Felipe|||0000-0002-4885-4334
  • Bermejo Martín, Jesús Francisco
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
13 p., Inspired by the diagnostic potential of micromotor technology, this study presents a novel magnetic micromotor-based electrochemical biosensing approach for the sensitive detection of spike (S) protein in microliter-scale sample volumes. Tubular MoS2/Ni magnetic micromotors are externally modified with gold nanoparticles (AuNPs) to enable the covalent immobilization of angiotensin-converting enzyme 2 (ACE2) as the capture probe, leveraging its intrinsic recognition capability and resilience to viral mutations for future-proof detection. The inner Ni layer provides biocompatible magnetic propulsion while simplifying washing and handling steps. The resulting ACE2/Au/MoS2/Ni micromotors are actively navigated for 20 min to efficiently capture the S protein/anti-S IgG/HRP-labeled secondary antibody immunocomplex. After capture, the micromotors are deposited onto a screen-printed electrode for chronoamperometric detection at ?0.1 V using 3,3?,5,5?-tetramethylbenzidine (TMB) as a redox mediator. Micromotor motion is shown to be crucial, enhancing the amperometric signal by approximately 50% in confined sample microenvironments. This clearly demonstrates the active role of micromotor propulsion in promoting target?receptor interactions and improving analytical performance. The biosensing platform achieves a low limit of detection (53 pg/mL) and high selectivity, with negligible cross-reactivity toward protein N and influenza A HA1. Importantly, validation in nasopharyngeal and plasma samples demonstrates the reliable classification of positive and negative cases, highlighting the suitability of the method for rapid screening applications. Overall, this micromotor-based strategy provides a robust, mutationresilient, and decentralized approach for precision biosensing of respiratory infections, with strong potential for future point-of-care development., Agencia Estatal de Investigación, Ministerio de Ciencia, Innovación y Universidades, Instituto de Salud Carlos III, Junta de Comunidades de Castilla-La Mancha, Universidad de Alcalá, Fondo Europeo de Desarrollo Regional, NextGenerationEU/PRTR, Unión Europea
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Affinity peptide-based magnetic micromotors for rapid, selective, ultra-sensitive, and reliable quantification of SARS-CoV-2 spike protein in microliter-scale nasopharyngeal and plasma samples from infected patients

  • Rodríguez Castillo, Alberto
  • Postigo, Tamara
  • Pérez García, Felipe|||0000-0002-4885-4334
  • Bermejo, Jesús
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Monitoring respiratory viruses is paramount to reducing the spread of the virus and associated costs, especially during the winter months. Here, we present magnetically propelled MoS2/Ni micromotors modified with a rhodamine B-labelled peptide that binds to the receptor-binding domain (RBD) on the S1 subunit of the spike protein (S). The approach uses an "on-the-fly" OFF-ON fluorescence method to detect the SARS-CoV-2 virus in two types of samples: nasopharyngeal and plasma samples, both types previously tested by molecular methods, and plasma samples additionally analyzed by serological assays. The micromotors move through the sample, inducing enhanced fluid mixing and increasing the number of peptide-spike protein biorecognition events, yielding an efficient operation using just 1 ?L of sample. The adsorbed peptide on MoS2 (OFF state) desorbs from the micromotors, due to interaction rhodamine B-labelled peptide-spike protein resulting in an increase in targetdependent fluorescence intensity in the solution measured using fluorescence microscopy (ON state). The approach takes just 1 min, displaying a linear range of 0.006?50 ng/mL with an excellent limit of detection of 1.8 pg/mL. The good agreement between the main infection indicators from nasopharyngeal and plasma samples, as measured by molecular and serological tests in the hospital, and the protein S concentration, as measured by our micromotor approach, demonstrates the applicability of the method for the rapid diagnosis of respiratory infections, opening new avenues for the diagnosis of respiratory infections. While the potency of the micromotor approach is demonstrated here, novel integration approaches are also envisioned in the near future., Ministerio de Ciencia, Innovación y Universidades, Junta de Comunidades de Castilla-La Mancha, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Cyclo-Octasulfur Crystals as Light-Controlled Molecular Muscles

  • Solano Rodríguez, Enrique
  • Sun, Qi
  • Bredás, Jean-Luc
  • Coropceanu, Veaceslav
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Here, we describe the synthesis and photo-responsive properties of 2D cyclo-octasulfur microcrystals (alpha-S8 MCs), produced using a quick, simple, cost-effective, and environmentally friendly hydrothermal method. Controlled 385-nm irradiation of these crystals induces an immediate, reversible, and sustained bending effect. The time required for the crystals to return to their initial shape is significantly reduced when exposed to 475-nm light, completing the entire excitation-relaxation cycle in less than 2 s. Moreover, this process can be repeated up to 50 times as long as the crystals remain in water. The dependence of recovery time on light wavelength is rationalized qualitatively via highly correlated quantum-chemical calculations of the absorption spectra of S8 chains. The underlying mechanism involves a combination of ring-to-chain and chain-to-ring transformations: the breaking of alpha-S8 rings by 385-nm radiation induces bending in the alpha-S8 MCs, while the excitation of the chains with 475-nm light facilitates an accelerated recovery process, allowing the S8 molecules to swiftly regain their ring shape. Thus, our study demonstrates that alpha-S8 MCs represent intelligent actuators as light-controlled molecular muscles with the simplest inorganic composition reported to date., Ministerio de Ciencia, Innovación y Universidades, European Commision