Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 17
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gold nanocluster fluorescence as an indicator for optical enzymatic nanobiosensors: choline and acetylcholine determination

  • Martín-Barreiro, Alba
  • Marcos, Susana de
  • Fuente, Jesús M. de la
  • Grazú, Valeria
  • Galbán, Javier
Gold nanoclusters (AuNCs) have been covalently linked to a FAD-dependent enzyme, choline oxidase (AuNCs@ChOx), with the objective of using the AuNCs fluorescence at 700 nm for monitoring the enzymatic reaction. The linking methodology has been optimized to obtain oriented binding and as a result the structure of the enzyme changes leading to an enhancement of the intrinsic FAD fluorescence of the enzyme (at 525 nm). During the enzymatic reaction with choline, the AuNCs@ChOx fluorescence intensity at both wavelengths (700 nm and 525 nm) changes proportionally to the choline concentration and can be simultaneously monitored. The mechanism of the analytical signal has been studied and a combination of FRET and O2 quenching was found to be responsible for the changes. A mathematical equation is proposed for modelling the signal. The combination of AuNCs@ChOx with acetylcholinesterase permitted the determination of acetylcholine in a concentration range from 1·10−6 to 1·10-5 M and RSD = 4%. This new approach can potentially be applied to any other flavo-enzyme in order to both increase their FAD fluorescence properties and to move the fluorescence measurement to the NIR region. The biosensor is reversible and avoids the use of conventional fluorophores, which are prone to chemical degradation and present worse biocompatibility., This work was supported by the MINECO of Spain (project CTQ2016-76846R) and research funding from DGA (Fondo Social Europeo) (E25_17R)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Use of tectomers for the immobilization of a biosensor to detect biogenic amines towards the development of smart food packaging

  • Oliver, Sofía
  • Navarro, Jesús
  • Marcos, Susana de
  • Garriga, Rosa
  • Muñoz, Edgar
  • Cebolla, Vicente L.
  • Sanz Vicente, Isabel
  • Jarne, Carmen
  • Galbán, Javier
2 Figures.-- Talk delivered in IX NYNA 2019 International Congress on Analytical Nanoscience and Nanotechnology in Zaragoza, Spain, 2-4 July 2019., Biogenic amines (BAs) are low molecular weight nitrogenous compounds that mainly result from the decarboxylation of free amino acids in food by microorganisms. At high concentrations, they cannot be metabolized by the body and pass to the blood stream, triggering intoxication processes.Because of the growing concern in food security, the quality control in food requires the development of fast and economic methods for the detection of BAs. Most methods are based on HPLC-MS techniques, and usually require a previous derivatization, so that they are expensive and tedious.The purpose of this work is the development of an optical sensor for the detection of BAs, as shown in Figure 1, where the enzymes amine oxidase (AO) and peroxidase (HRP), and a dye (ABTS) are immobilized on mica supports, so that the dye turns blue in presence of BAs., This work has been carried out under the Project CTQ2016-76846R (MINECO) and the aid to the research groups DGA-FEDER (E25_17R)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Colorimetric-enzymatic determination of tyramine by generation of gold nanoparticles

  • Navarro, Jesús
  • Marcos, Susana de
  • Galbán, Javier
In this paper, it has been demonstrated that Au(III) is able to act instead of O2 in the oxidase enzymatic reaction, so that it becomes reduced to purple gold nanoparticles (AuNPs). The plasmon band (at 540 nm) can be used as the analytical signal. Tyramine has been determined using its enzymatic reaction with tyramine oxidase (TAO). The kinetic of the AuNP formation has been studied in the light of both the Avrami equation for crystallization and the Finke-Watsy mechanism for AuNP nucleation and growth. The effects of the Au(III), TAO and tyramine concentrations on the corresponding kinetic constants have been investigated. Working at room temperature, under optimal conditions (phosphate buffer pH 7.0, TAO 0.5 U.mL−1 Au(III) 1 mM), the linear response ranges from 2.5 × 10−5 M to 3.3 × 10−4 M Tyramine (5.6% RSD) and the LOD is 2.9 × 10−6 M. Under these conditions, the signal is measured after 30 min reaction (to obtain the highest sensitivity), but this time can be significantly reduced by increasing the temperature (the reaction is finished after 4 min when working at 50 °C). The method has been applied to tyramine determination in a cheese sample with good results. The new scheme proposed in this paper can be extended, in principle, to other enzymatic methods based on oxidase enzymes., The authors thank the Ministry of Economy and Finance (MINECO) of Spain (CTQ2016-76846R) and the Research Groups funding of the Government of Aragón (group E25_17R), for financial support. J Navarro thanks the Government of Aragón (DGA) for a grant., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Scanning densitometry and mass spectrometry for HPTLC analysis of lipids: The last 10 years

  • Cebolla, Vicente L.
  • Jarne, Carmen
  • Vela, Jesús
  • Garriga, Rosa
  • Membrado, Luis
6 figures, 4 tables., This work is a review on HPTLC contribution to lipid analysis in complex matrices, in the period from 2010 to now, lapse of time where hyphenation with other techniques, especially Mass Spectrometry, has experienced an important growth. Scanning densitometry (SD)-UV/FL of separated lipids, as the core of detection and centerpiece for hyphenation, and its coupling with MS using soft ionization techniques (ESI, APCI, MALDI, DESI and others), are the central axis of this work. The occasional intercalation in this coupling of an on-plate biological assay for effect-direct analysis (EDA) of lipids, as well as the combination of SD with radio-densitometry (RD) using isotopically labeled-lipids are also covered topics. The described techniques make possible to develop strategies for obtaining qualitative and different levels of quantitative information, including untargeted lipids species. HPTLC of lipids has been used for: comparative purposes; fingerprinting; semi-quantitative determination, identification of species; or quantitative determination of a given individual lipid. Goals in molecular biology and biochemistry-related samples have been: preparative isolations; control of purity; verification of metabolic products; on-plate biological assays; profiles in cells; analysis of products from the cellular metabolism; measurement of enzymatic activities; monitoring lipid transport across membranes or at biological interfaces; or monitoring lipid dynamics., One of us (J.G.) thanks to Spanish Plan Nacional I + D+i (CTQ2016-76846R project). This work was supported by DGA-ESF [project 25_20R]., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Globotriaosylceramide-related biomarkers of fabry disease identified in plasma by high-performance thin-layer chromatography - densitometry - mass spectrometry

  • Jarne, Carmen
  • Membrado, Luis
  • Savirón, María
  • Vela, Jesús
  • Orduna, Jesús
  • Garriga, Rosa
  • Galbán, Javier
  • Cebolla, Vicente L.
6 figures, 2 tables.-- Supplementary information available.-- © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/, Identification of 19 molecular species of globotriaosylceramides (Gb3) in extracts from a Fabry's plasma patient and a healthy control was performed by High-Performance Thin-Layer Chromatography (HPTLC)-densitometry and online coupling to Mass Spectrometry (MS). Separation was carried out on LiChrospher plates using Automated Multiple Development (AMD). Densitometry was performed on twin plates by combining detection in the visible at 550 nm, through previous on-plate orcinol derivatization, and by Ultraviolet 190 nm, using a non-impregnated plate. The latter was directly coupled to an ion-trap mass spectrometer through an automated elution-based interface. Gb3 molecular species, which were identified by HPTLC- Electrospray Mass Spectrometry (+)-MS and confirmed by MS/MS or HPTLC-Atmospheric Pressure Chemical Ionization Mass Spectrometry (+)-MS, are: five isoforms of saturated Gb3; seven isoforms of methylated Gb3; and seven species with two additional double bonds. Twelve of these species were previously reported as biomarkers of Fabry's lysosomal disorder using a Liquid Chromatography-MS-based method, and the other seven are structurally similar, closely related to them. Saturated Gb3 isoforms migrated on LiChrospher plate in one of the separated peaks corresponding to the migration zone of ceramide trihexosides standard. Instead, methylated and unsaturated Gb3 species co-migrated with sphingomyelin species. Ion intensity ESI-MS profiles show that saturated Gb3 species in Fabry's plasma were in higher concentration than in control sample. Before applying the Thin-Layer Chromatography (TLC)-MS interface on HPTLC separated peaks, its positioning precision was first studied using ceramide tri-hexosides as model compound. This provided information on Gb3 peak broadening and splitting during its migration., This work was supported by DGA-FEDER (E25_17R, N&SB). One of us (J.G.) thanks to Spanish Plan Nacional I+D+i (CTQ2016-76846-R project)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Direct minimally invasive enzymatic determination of tyramine in cheese using digital imaging

  • Oliver, Sofía
  • Marcos, Susana de
  • Sanz Vicente, Isabel
  • Cebolla, Vicente L.
  • Galbán, Javier
9 figures, 2 multimedia components.-- © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/, An enzymatic method for the direct (without pretreatment) minimally invasive tyramine determination in cheese is proposed. Colorimetric test strips containing tyramine oxidase (TAO), peroxidase and 3,3′,5,5′-tetramethylbenzidine (Q-TAO), allow tyramine determination through the RGB chromatic coordinates of the observed blue colour (LOD = 2.6·10−6 M, LOQ = 8.7·10−6 M, RSD% (n = 5; 1.8·10−4 M) = 3.2%). The strips are inserted in the sample for 2 min and then the RGB coordinates are measured using a smartphone. Previously, these Q-TAO strips have been also optimized for tyramine determination in cheese extract. To do that, a spectrophotometric method in solution for tyramine determination in cheese extracts has been developed, which included an in-depth study of the indicating reaction; this study has allowed to gain new information about the spectroscopic properties of different TMB species and, which it is more important, to detect cross-reactions between TAO and TMB species. A mathematical model has also been developed which relate the RGB signals obtained with the tyramine concentrations, the instrumental characteristics of the smartphone and the spectroscopic properties of the absorbing product of the enzymatic reaction., This work was supported by the MINECO of Spain (projects CTQ2016-76846R and PID2019-105408 GB-I00) and by Research groups funded by DGA-FEDER (group E25_17R, N&SB)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gold nanoparticle formation as an indicator of enzymatic methods: colorimetric l-phenylalanine determination

  • Martín-Barreiro, Alba
  • Marcos, Susana de
  • Galbán, Javier
An enzymatic-colorimetric method has been developed based on the reaction between L-phenylalanine (L-Phe) and the L-amino acid oxidase (LAAO) in the presence of Au(III), which has led to the formation of gold nanoparticles. The intensity of the localized surface plasmon resonance (LSPR) band of the generated nanoparticles (550 nm) can be related to the concentration of L-Phe in the sample. The mechanism of the LAAO-L-Phe enzyme reaction in the presence of Au(III) has been studied through the evaluation and optimization of experimental conditions. These studies have reinforced the hypothesis that the catalytic center of the enzyme helps the Au(III) reduction and, thanks to the protein, the Au0 form is stabilized as gold nanoparticles (AuNPs). In the calibration study, a sigmoidal relationship between the concentration of the substrate and the LSPR of the nanoparticles was observed. The linearization of the signal has allowed the determination of L-Phe in the range from 17 to 500 µM with an RSD% (150 μM) of 4.8% (n = 3). The method is free of other amino acid interference normally found in blood plasma. These highly competitive results open the possibility of further development of a rapid method for L-Phe determination based on colorimetry., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., This work was supported by the projects CTQ2016-76846R (AEI/FEDER, UE) and PID2019-105408 GB-100 / AEI / 10.13039/501100011033 of the Government of Spain and funded by the Research Groups of DGA-FEDER (group E25_20R)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Analytical possibilities of Putrescine and Cadaverine enzymatic colorimetric determination in tuna based on diamine oxidase: A critical study of the use of ABTS

  • Navarro, Jesús
  • Sanz Vicente, Isabel
  • Lozano, Rebeca
  • Marcos, Susana de
  • Galbán, Javier
The joint determination of putrescine (Put) and cadaverine (Cad) in the presence of other biogenic amines is studied using their enzymatic reaction with diamine oxidase (DAO). Three alternative methods are studied based on the intrinsic colorimetric properties of DAO or horseradish peroxidase (HRP), and the use of 2,2′-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) colorimetric reagent, respectively. In this last case an in-depth study is carried out in order to explain and solve some drawbacks usually associated with the use of this reagent (especially interferences, interaction with enzymes and instability), and to propose new analytical methodologies which this reagent allows to achieve (transient signal and the use of the violet species). Finally, the method has been applied to Put + Cad determination in a tuna sample without interference of other biogenic amines. The result has been compared with that obtained using a method based on HPLC-MS, which has allowed the new methodology to be validated., This work was supported by the MINECO of Spain (project CTQ2016-76846R) and by Research groups funded by DGA-FEDER (group E25_17R). J Navarro thanks the Government of Aragon (DGA) for a grant. The authors are also very grateful to Dr. Francisco Palacios and MSc Cristina Asensio from the Laboratorio de Salud Pública de Aragón (LSPA, DGA) for their invaluable help., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gold nanoclusters as a quenchable fluorescent probe for sensing oxygen at high temperatures

  • Martín-Barreiro, Alba
  • Marcos, Susana de
  • Galbán, Javier
Gold nanoclusters (AuNCs) capped with lipoic acid (LA) or templated with bovine serum albumin (BSA) are shown to be viable fluorescent probes for oxygen (O2) which acts as a collisional quencher. Quenching of fluorescence, with its lifetimes in the order of 123 ± 9 ns (LA) and 153 ± 15 ns (BSA) (in aqueous solution), is best measured at excitation/emission wavelengths of 400/680 nm and 375/650 nm respectively. It follows the Stern-Volmer model, whose quenching constants (Ksv) and quenching efficiencies (γ) are 1400 M-1 and 0.52 for AuNC@LA and 4479 M-1 and 0.90 for AuNC@BSA. The probes were immobilized on a silica support and tested for response to O2 in gas phase using a commercial instrument. The effect of temperature on the fluorescence of AuNC@LA was studied in the range from 30 to 210 °C. Fluorescence intensity slightly decreases with temperature in the first heating cycle but remains constant in further cycles. The AuNC@LA were studied for their response to O2 in the temperature range from 30 to 100 °C, and even at 100 °C they respond to O2, with a Ksv that slightly drops with increasing temperature. Measuring in gas phase at 100 °C, the sensor has a detection limit of 3% (V/V) of O2 at a signal-to-noise ratio of 3. Graphical Abstract Gold-nanoclusters (AuNCs) fluorescence intensity (λexc = 400 nm, λem = 680 nm) remains constant from 30 to 210 °C and is quenched by O2 following a collisional mechanism. The Stern-Volmer constant (Ksv) slightly changes from 25 °C to 100 °C (at least)., The authors thank to MINECO of Spain (CTQ2016-76846R), DGA-FEDER funding to Research Groups (E74) and BSH (project “Smart Ovens III”) for financial support., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Smartphone-interrogated test supports for the enzymatic determination of putrescine and cadaverine in food

  • Sanz Vicente, Isabel
  • López-Molinero, Ángel
  • Marcos, Susana de
  • Navarro, Jesús
  • Cebrián, Pablo
  • Arruego, Chantal
  • Visiedo, Victor
  • Galbán, Javier
Diamino-oxidase (DAO), horseradish peroxidase (HRP), and tetramethylbenzidine (TMB) have been immobilized into cellulose to obtain circular cellulose test supports (CCTSs) for the determination of cadaverine (Cad) and putrescine (Put). During the enzymatic reaction, TMB is oxidized and a blue spot is obtained. This color (RGB coordinates) is measured with a smartphone and a commercial application. The highest sensitivity is provided by the component R and a linear response is observed for low biogenic amine (BA) concentrations, but a second-order polynomial response better fits the experimental results for a wider concentration range. This has been successfully explained with a model developed to explain the RGB values obtained in this type of analytical system. Optimization studies enable CCTSs to be obtained for Put and Cad determination, which could be used (kept at 4 °C) for at least 45 days if a stabilizer (StabilCoat™ or StabilGuard™) is added during its synthesis. In these conditions, the R coordinate follows the model up to at least 4 × 10-4 M Put and/or Cad (both analytes give the same response). The method permits the Put and Cad determination from 5 × 10-5 M up to 4 × 10-4 M (RSD = 3%, n = 3). The CCTSs have been applied to Put + Cad determination in a tuna sample without any interference by other biogenic amines. The concentration found statistically agrees with that obtained using a HPLC-MS-validated method., This work was supported by the MINECO of Spain (project CTQ2016-76846R) and by research groups funding DGA-FEDER (group E25_17R)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Hacia la determinacion in situ de aminas biogenas.

  • López Molinero, Ángel Javier
Las aminas biógenas (AB) son una familia muy amplia de biomoléculas de bajo peso molecular que poseen en su estructura al menos un grupo amino. Realizan múltiples funciones, especialmente neurotransmisoras y hormonales, por lo que el organismo dispone de una ruta para su síntesis a partir de los aminoácidos precursores (descarboxilación con Aminoácido Descarboxilasa, AAAD); sin embargo, su exceso puede provocar problemas de intolerancia o intoxicaciones, por lo que también tiene mecanismos para su regulación (oxidación metabólica con Diamino Oxidasa, (DAO), o la ruta de la Monoaminooxidasa (MAO)...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Gold nanoclusters as a quenchable fluorescent probe for sensing oxygen at high temperatures

  • Martín-Barreiro, A.
  • Marcos, S. de
  • Galbán, J.
Gold nanoclusters (AuNCs) capped with lipoic acid (LA) or templated with bovine serum albumin (BSA) are shown to be viable fluorescent probes for oxygen (O2) which acts as a collisional quencher. Quenching of fluorescence, with its lifetimes in the order of 123 ± 9 ns (LA) and 153 ± 15 ns (BSA) (in aqueous solution), is best measured at excitation/emission wavelengths of 400/680 nm and 375/650 nm respectively. It follows the Stern-Volmer model, whose quenching constants (Ksv) and quenching efficiencies (¿) are 1400 M-1 and 0.52 for AuNC@LA and 4479 M-1 and 0.90 for AuNC@BSA. The probes were immobilized on a silica support and tested for response to O2 in gas phase using a commercial instrument. The effect of temperature on the fluorescence of AuNC@LA was studied in the range from 30 to 210 °C. Fluorescence intensity slightly decreases with temperature in the first heating cycle but remains constant in further cycles. The AuNC@LA were studied for their response to O2 in the temperature range from 30 to 100 °C, and even at 100 °C they respond to O2, with a Ksv that slightly drops with increasing temperature. Measuring in gas phase at 100 °C, the sensor has a detection limit of 3% (V/V) of O2 at a signal-to-noise ratio of 3. [Figure not available: see fulltext.].
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Analytical possibilities of Putrescine and Cadaverine enzymatic colorimetric determination in tuna based on diamine oxidase: A critical study of the use of ABTS

  • Navarro, Jesús
  • Sanz-Vicente, Isabel
  • Lozano, Rebeca
  • de Marcos, Susana
  • Galbán, Javier
The joint determination of putrescine (Put) and cadaverine (Cad) in the presence of other biogenic amines is studied using their enzymatic reaction with diamine oxidase (DAO). Three alternative methods are studied based on the intrinsic colorimetric properties of DAO or horseradish peroxidase (HRP), and the use of 2, 2'-Azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) diammonium salt (ABTS) colorimetric reagent, respectively. In this last case an in-depth study is carried out in order to explain and solve some drawbacks usually associated with the use of this reagent (especially interferences, interaction with enzymes and instability), and to propose new analytical methodologies which this reagent allows to achieve (transient signal and the use of the violet species). Finally, the method has been applied to Put + Cad determination in a tuna sample without interference of other biogenic amines. The result has been compared with that obtained using a method based on HPLC-MS, which has allowed the new methodology to be validated.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Smartphone-interrogated test supports for the enzymatic determination of putrescine and cadaverine in food

  • Sanz-Vicente, I.
  • López-Molinero, Á.
  • de Marcos, S.
  • Navarro, J.
  • Cebrián, P.
  • Arruego, C.
  • Visiedo, V.
  • Galbán, J.
  • Navarro Domínguez, Jesús Mª.
Diamino-oxidase (DAO), horseradish peroxidase (HRP), and tetramethylbenzidine (TMB) have been immobilized into cellulose to obtain circular cellulose test supports (CCTSs) for the determination of cadaverine (Cad) and putrescine (Put). During the enzymatic reaction, TMB is oxidized and a blue spot is obtained. This color (RGB coordinates) is measured with a smartphone and a commercial application. The highest sensitivity is provided by the component R and a linear response is observed for low biogenic amine (BA) concentrations, but a second-order polynomial response better fits the experimental results for a wider concentration range. This has been successfully explained with a model developed to explain the RGB values obtained in this type of analytical system. Optimization studies enable CCTSs to be obtained for Put and Cad determination, which could be used (kept at 4 °C) for at least 45 days if a stabilizer (StabilCoat™ or StabilGuard™) is added during its synthesis. In these conditions, the R coordinate follows the model up to at least 4 × 10-4 M Put and/or Cad (both analytes give the same response). The method permits the Put and Cad determination from 5 × 10-5 M up to 4 × 10-4 M (RSD = 3%, n = 3). The CCTSs have been applied to Put + Cad determination in a tuna sample without any interference by other biogenic amines. The concentration found statistically agrees with that obtained using a HPLC-MS-validated method.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Direct minimally invasive enzymatic determination of tyramine in cheese using digital imaging

  • Oliver S.
  • Marcos S. de
  • Sanz-Vicente I.
  • Cebolla V.
  • Galbán J.
An enzymatic method for the direct (without pretreatment) minimally invasive tyramine determination in cheese is proposed. Colorimetric test strips containing tyramine oxidase (TAO), peroxidase and 3, 3', 5, 5'-tetramethylbenzidine (Q-TAO), allow tyramine determination through the RGB chromatic coordinates of the observed blue colour (LOD = 2.6·10-6 M, LOQ = 8.7·10-6 M, RSD% (n = 5; 1.8·10-4 M) = 3.2%). The strips are inserted in the sample for 2 min and then the RGB coordinates are measured using a smartphone. Previously, these Q-TAO strips have been also optimized for tyramine determination in cheese extract. To do that, a spectrophotometric method in solution for tyramine determination in cheese extracts has been developed, which included an in-depth study of the indicating reaction; this study has allowed to gain new information about the spectroscopic properties of different TMB species and, which it is more important, to detect cross-reactions between TAO and TMB species. A mathematical model has also been developed which relate the RGB signals obtained with the tyramine concentrations, the instrumental characteristics of the smartphone and the spectroscopic properties of the absorbing product of the enzymatic reaction. © 2021 Elsevier B.V.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Gold nanoparticle formation as an indicator of enzymatic methods: colorimetric L-phenylalanine determination

  • Martín-Barreiro, Alba
  • de Marcos, Susana
  • Galbán, Javier
An enzymatic-colorimetric method has been developed based on the reaction between l-phenylalanine (l-Phe) and the l-amino acid oxidase (LAAO) in the presence of Au(III), which has led to the formation of gold nanoparticles. The intensity of the localized surface plasmon resonance (LSPR) band of the generated nanoparticles (550 nm) can be related to the concentration of l-Phe in the sample. The mechanism of the LAAO-l-Phe enzyme reaction in the presence of Au(III) has been studied through the evaluation and optimization of experimental conditions. These studies have reinforced the hypothesis that the catalytic center of the enzyme helps the Au(III) reduction and, thanks to the protein, the Au0 form is stabilized as gold nanoparticles (AuNPs). In the calibration study, a sigmoidal relationship between the concentration of the substrate and the LSPR of the nanoparticles was observed. The linearization of the signal has allowed the determination of l-Phe in the range from 17 to 500 µM with an RSD% (150 μM) of 4.8% (n = 3). The method is free of other amino acid interference normally found in blood plasma. These highly competitive results open the possibility of further development of a rapid method for l-Phe determination based on colorimetry.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Globotriaosylceramide-related biomarkers of fabry disease identified in plasma by high-performance thin-layer chromatography - densitometry- mass spectrometry

  • Jarne, C.
  • Membrado, L.
  • Savirón, M.
  • Vela, J.
  • Orduna, J.
  • Garriga, R.
  • Galbán, J.
  • Cebolla, V.L.
Identification of 19 molecular species of globotriaosylceramides (Gb3) in extracts from a Fabry''s plasma patient and a healthy control was performed by High-Performance Thin-Layer Chromatography (HPTLC)-densitometry and online coupling to Mass Spectrometry (MS). Separation was carried out on LiChrospher plates using Automated Multiple Development (AMD). Densitometry was performed on twin plates by combining detection in the visible at 550 nm, through previous on-plate orcinol derivatization, and by Ultraviolet 190 nm, using a non-impregnated plate. The latter was directly coupled to an ion-trap mass spectrometer through an automated elution-based interface. Gb3 molecular species, which were identified by HPTLC- Electrospray Mass Spectrometry (+)-MS and confirmed by MS/MS or HPTLC-Atmospheric Pressure Chemical Ionization Mass Spectrometry (+)-MS, are: five isoforms of saturated Gb3; seven isoforms of methylated Gb3; and seven species with two additional double bonds. Twelve of these species were previously reported as biomarkers of Fabry''s lysosomal disorder using a Liquid Chromatography-MS-based method, and the other seven are structurally similar, closely related to them. Saturated Gb3 isoforms migrated on LiChrospher plate in one of the separated peaks corresponding to the migration zone of ceramide trihexosides standard. Instead, methylated and unsaturated Gb3 species co-migrated with sphingomyelin species. Ion intensity ESI-MS profiles show that saturated Gb3 species in Fabry''s plasma were in higher concentration than in control sample. Before applying the Thin-Layer Chromatography (TLC)-MS interface on HPTLC separated peaks, its positioning precision was first studied using ceramide tri-hexosides as model compound. This provided information on Gb3 peak broadening and splitting during its migration.