Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A dual colorimetric-electrochemical microfluidic paper-based analytical device for point-of-care testing of ischemic strokes

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Pacheco Jerez, Marta|||0000-0001-9546-9108
  • Gasull Dalmau, Teresa|||0000-0002-9321-1741
  • Crevillen, Agustín G.|||0000-0002-4470-6502
  • Escarpa, Alberto|||0000-0002-7302-0948
A novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual μPAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated from the ratio between transferrin-bound iron, which was colorimetrically measured, and the total iron-binding capacity, which was electrochemically measured. To this end, a μPAD was smartly designed, which integrated both colorimetric and electrochemical detection reservoirs, communicating via a microchannel acting as a chemical reactor, and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability of the results due to an independent signal principle and processing. The μPADs were validated by analyzing a certified reference material, showing excellent accuracy (E ≤ 5%) and precision (RSD ≤ 2%). Then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05) and no significant differences were found between them (slope 1.0 ± 0.1 and the intercept 1 ± 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 μL of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical μPAD is a promising ready to use reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic strokes, where the decision-time is crucial for the patient's survival.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Near infrared-light responsive WS2 microengines with high-performance electro- And photo-catalytic activities

  • Asunción-Nadal, Víctor de la
  • Jurado-Sánchez, Beatriz
  • Vázquez Burgos, Luis
  • Escarpa, Alberto
[EN] Tungsten disulfide (WS)-based micromotors with enhanced electrochemical and photo-catalytic activities are synthesized using a greatly simplified electrochemical deposition protocol at room temperature involving exclusively tungstic acid and sulfate as metal and sulfur sources without further building chemistry. The WS-based micromotors exhibit dual electrochemical and photo-catalytic behavior in the inner and outer layers, respectively, due to the combination of the unique properties of the sp hybridized WS outer layer with highly reactive WS-induced inner catalytic layers, accounting for this material's exclusive enhanced performances. A rough inner Pt-Ni layer allows tailoring the micromotor propulsion, with a speed increase of up to 1.6 times after external control of the micromotor with a magnetic field due to enhanced fuel accessibility. Such a coupling of the attractive capabilities of WS with enhanced micromotor movement holds considerable promise to address the growing energy crisis and environmental pollution concerns., V. de la Asunción-Nadal acknowledges the FPI fellowship received from the University of Alcalá. B. J.-S. acknowledges support from the Spanish Ministry of Science, Innovation and Universities (RYC-2015-17558, co-financed by EU) and the University of Alcalá (CCG2018/EXP-018). AE acknowledges Financial support from the Spanish Ministry of Science, Innovation and Universities (CTQ2017-86441-C2-1-R) and theTRANSNANOAVANSENS program (S2018/NMT-4349) from the Community of Madrid. LV acknowledges Financial support from the Spanish Ministry of Science, Innovation and Universities (MAT2017-85089-C2-1-R).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of nanocellulose polymorphism on electrochemical analytical performance in hybrid nanocomposites with non-oxidized single-walled carbon nanotubes

  • Dortez, Silvia
  • Sierra, Tania
  • Álvarez Sánchez, Miguel Ángel
  • González Domínguez, José Miguel
  • Benito, Ana M.
  • Maser, Wolfgang K.
  • Crevillén, Agustín G.
  • Escarpa, Alberto
4 figures, 2 tables., Two cellulose nanocrystals/single-walled carbon nanotube (CNC/SW) hybrids, using two cellulose polymorphs, were evaluated as electrochemical transducers: CNC type I (CNC-I/SW) and CNC type II (CNC-II/SW). They were synthesized and fully characterized, and their analytical performance as electrochemical sensors was carefully studied. In comparison with SWCNT-based and screen-printed carbon electrodes, CNC/SW sensors showed superior electroanalytical performance in terms of sensitivity and selectivity, not only in the detection of small metabolites (uric acid, dopamine, and tyrosine) but also in the detection of complex glycoproteins (alpha-1-acid glycoprotein (AGP)). More importantly, CNC-II/SW exhibited 20 times higher sensitivity than CNC-I/SW for AGP determination, yielding a LOD of 7 mg L−1.These results demonstrate the critical role played by nanocellulose polymorphism in the electrochemical performance of CNC/SW hybrid materials, opening new directions in the electrochemical sensing of these complex molecules. In general, these high-active-surface hybrids smartly exploited the preserved non-oxidized SW conductivity with the high aqueous dispersibility of the CNC, avoiding the use of organic solvents or the incorporation of toxic surfactants during their processing, making the CNC/SW hybrids promising nanomaterials for electrochemical detection following greener approaches., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been financially supported by the TRANSNANOAVANSENS program from the Community of Madrid (P2018/NMT-4349), and the Spanish Ministry of Economy and Competitiveness (CTQ2017-86441-C2-1-R). Additional funding support was from Spanish MINEICO/MICINN under project with references ENE2016-79282-C5-1-R (AEI/FEDER/UE), PID2019-104272RB-C51/AEI/10.13039/501100011033, and PID2020-120439RA-I00. Funding support from Gobierno de Aragón (Grupo Reconocido T03_20R) is also acknowledged., Peer reviewed
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Gregorio-Rocasolano Barbany, Núria de|||0000-0001-5248-7525
  • Millán Torné, Mònica|||0000-0002-4692-5936
  • Gasull Dalmau, Teresa|||0000-0002-9321-1741
  • Crevillen, Agustín G.|||0000-0002-4470-6502
  • Escarpa, Alberto|||0000-0002-7302-0948
For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (E < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Visible light driven Janus microvehicles in biological media

  • Pacheco Jerez, Marta|||0000-0001-9546-9108
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
A light-driven multifunctional Janus micromotor for the removal of bacterial endotoxins and heavy metals is described. The micromotor was assembled by using the biocompatible polymer polycaprolactone for the encapsulation of CdTe or CdSe@ZnS quantum dots (QDs) as photoactive materials and an asymmetric Fe3O4 patch for propulsion. The micromotors can be activated with visible light (470-490 nm) to propel in peroxide or glucose media by a diffusiophoretic mechanism. Efficient propulsion was observed for the first time in complex samples such as human blood serum. These properties were exploited for efficient endotoxin removal using lipopolysaccharides from Escherichia coli O111:B4 as a model toxin. The micromotors were also used for mercury removal by cationic exchange with the CdSe@ZnS core-shell QDs. Cytotoxicity assays in HeLa cell lines demonstrated the high biocompatibility of the micromotors for future detoxification applications., Ministerio de Ciencia e Innovación, European Commission, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Gold-nanostructure related non-plasmon resonance absorption band as a fingerprint of ortho-alkyl substituted phenolic compounds

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • González Martín, María Cristina
  • González Crevillén, Agustín
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
6 p., A systematic study for correlating the chemical structure of phenolic compounds with their capacity to form gold nanoparticles was carried out. Two groups of phenolic compounds were selected: one group with a substituent with different size at ortho position respect to hydroxyl group (phenol, o-cresol, 2-ethylphenol, 2-isopropylphenol, 2-tert-butylphenol and 2-methoxyphenol); and the second group consists of phenolic compounds with the same substituent (methyl) at different positions respect to hydroxyl group (o-cresol, m-cresol and pcresol). In addition to the characteristic gold nanoparticles (AuNPs) formation band at 550 nm obtained for all the structures of phenolic compounds studied, ortho-alkyl substituted yielded selectively a metastable band at 400 nm, due to gold nanoclusters (AuNCs) formation. We hypothesized that these specific phenolic compounds can temporally stabilize AuNCs with number of Au atoms ranging from 3 to 41. This new band was proposed for rapid screening of these phenolics with promising results, paving the way to new and more selective colorimetric assay for phenolic compounds determination., Comunidad de Madrid, Ministerio de Economía y Competitividad
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Integrated calibration and serum iron in situ analysis into an array microfluidic paper-based analytical device with smartphone readout

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
7 p., In this work, a colorimetric microfluidic paper-based analytical device (mu PAD) combined with a smartphone readout was proposed for the determination of serum iron (Fe3+), which is linked to transferrin. Firstly, Fe3+ was selectively isolated and preconcentrated from serum by using anti-transferrin immunomagnetic beads (anti-Tf-MBs). Secondly, Fe3+ is reduced to Fe2+ by a hydroxylamine solution (pH 4.8) and then measured in the mu PAD, which contains the colorimetric reagent ferrozine. Finally, the intensity of the purple color formed in the mu PAD was measured by a smartphone. The approach exhibited an excellent linear correlation (r = 0.996) and good limit of detection (0.3 mu g mL(-1)). Moreover, a certified reference material (human serum) was analyzed by this approach, showing an excellent accuracy (Er < 4%) and inter-device reproducibility (RSD = 1%, n = 3). Interestingly, the mu PAD array-design allowed the simultaneous analysis of different samples, improving the sample throughput (up to 5 samples in 130 min, using 100 mu L each), and the integration of calibration and analysis into the same device, simplifying the analysis without losing accuracy or sensitivity, and avoiding inter -device variability, which constituted an added value to this approach. These disposable mu PADs meet several requirements of point-of-care testing (POCT) because it is cheap, portable, easy-to-use, sensitive, and specific. Therefore, it may be an interesting way for measuring patients' serum iron levels in situ with reliability, especially, in developing countries, where the prevalence of iron deficiency and iron-deficiency anemia is higher and there are lower health resources than in developed countries., Comunidad de Madrid, Ministerio de Economía y Competitividad, Ministerio de Ciencia e Innovación
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Smartphone-based Janus micromotors strategy for motion-based detection of glutathione

  • Kaisong, Yuan
  • Cuntín Abal, Carmen|||0000-0001-5713-0971
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Herein, we describe a Janus micromotor smartphone platform for the motion-based detection of glutathione. The system compromises a universal three-dimensional (3D)-printed platform to hold a commercial smartphone, which is equipped with an external magnification optical lens (20-400x) directly attached to the camera, an adjustable sample holder to accommodate a glass slide, and a light-emitting diode (LED) source. The presence of glutathione in peroxide-rich sample media results in the decrease in the speed of 20 mu m graphene-wrapped/PtNPs Janus micromotors due to poisoning of the catalytic layer by a thiol bond formation. The speed can be correlated with the concentration of glutathione, achieving a limit of detection of 0.90 mu M, with percent recoveries and excellent selectivity under the presence of interfering amino acids and proteins. Naked-eye visualization of the speed decrease allows for the design of a test strip for fast glutathione detection (30 s), avoiding previous amplification strategies or sample preparation steps. The concept can be extended to other micromotor approaches relying on fluorescence or colorimetric detection for future multiplexed schemes., Ministerio de Ciencia e Innovación, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Dual-Propelled Lanbiotic Based Janus Micromotors for Selective Inactivation of Bacterial Biofilms

  • Kaisong, Yuan
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Graphene oxide/PtNPs/Fe2O3 "dual-propelled" catalytic and fuel-free rotary actuated magnetic Janus micromotors modified with the lanbiotic Nisin are used for highly selective capture/inactivation of gram-positive bacteria units and biofilms. Specific interaction of Nisin with the Lipid II unit of Staphylococcus Aureus bacteria in connection with the enhanced micromotor movement and generated fluid flow result in a 2-fold increase of the capture/killing ability (both in bubble and magnetic propulsion modes) as compared with free peptide and static counterparts. The high stability of Nisin along with the high towing force of the micromotors allow for efficient operation in untreated raw media (tap water, juice and serum) and even in blood and in flowing blood in magnetic mode. The high selectivity of the approach is illustrated by the dramatically lower interaction with gram-negative bacteria (Escherichia Coli). The double-propulsion (catalytic or fuel-free magnetic) mode of the micromotors and the high biocompatibility holds considerable promise to design micromotors with tailored lanbiotics that can response to the changes that make the bacteria resistant in a myriad of clinical, environmental remediation or food safety applications., Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Electroanalytical paper-based device for reliable detection and quantification of sugars in milk

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Cinti, Stefano
7 p., Knowing the level of sugars in food and beverages is essential because they are related to diseases such as diabetes, and obesity, among others. In this regard, an approach has been designed, characterized, and applied to develop the first all-in-one paper-based microfluidic analytical device for the quantification of sugars in milk samples. In particular, the powerful combination of the paper-based platform, the facile manufacturing, and the on-demand customization, allowed to obtain a stand-alone platform that was capable to store all the reagents necessary for the assay, to treating the sample by removing major interferences due to lipids and proteins, and to visualize the results in minutes. A wax-patterned chromatographic paper was finely designed to provide a reagent-free platform for the use of non-specialists applied towards the analysis of sugars? content (lactose as the main sugar). Sugars were electrochemically quantified down to 0.16 g L-1 with a repeatability of 5%. To strengthen the efficacy of the novel platform, the electrochemical paper-based analytical device has been applied to commercial milk, including skimmed, semi-skimmed, whole, and lactose-free, confirming satisfactory performance with analytical reliability. This paper-based architecture opens novel avenues for portable (bio)sensing of other relevant species, not only in the agri-food field., Comunidad de Madrid, Ministerio de Economía y Competitividad, Universidad de Nápoles Federico II
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

An on-chip microfluidic-based electrochemical magneto-immunoassay for procalcitonin determination in plasma from sepsis diagnosed preterm neonates

  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Molinero Fernández, Águeda
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
A novel on-chip electrochemical magneto-immunoassay for Procalcitonin (PCT) determination is proposed. The strategy implies the on-line performing of the biorecognition event and the detection onto thin film microfluidic gold electrodes chamber operating at E= ?0.20 V (vs Au). The complete assay was performed in less than 15 minutes using only 25 ?L of sample, covering the entire spectrum of relevant clinically PCT concentrations in sepsis diagnosis and with a limit of detection and quantification of 0.02 ng/mL and 0.05 ng/mL, respectively (sepsis diagnosis threshold: 0.5 ng/mL). The onchip electrochemical magneto-immunoassay provided excellent results in the analysis of very unique samples coming from preterm neonates with sepsis suspicion, in which sample volume is hardly available. These characteristics fulfill the POCT requirements for PCT determination in the whole relevant clinical concentrations. Because of the high clinical relevance and the important role of PCT in sepsis, this approach opens new perspectives for the sepsis diagnosis and therapy guidance using low volume samples., La Caixa, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

2D Nanomaterials wrapped Janus micromotors with built-in multiengines for bubble, magnetic, and light driven propulsion

  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Kaisong, Yuan
  • Asunción Nadal, Víctor de la
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
Graphene oxide, graphdyine oxide, and blackphosphorus coated micromotors integrating "three engines" for motion control using different stimuli such as chemical fuel, light, and magnetic fields are described. Micromotors can be massproduced by wrapping gold-sputtered polystyrene microspheres with the 2D nanomaterials, followed by simultaneous assembly of Pt or MnO2 nanoparticles (NPs) as bubble (catalytic)-engines, Fe2O3 NPs as magnetic engines, and quantum dots (QDs) as light engines. The design and composition of micromotors are key to get the desired propulsion performance. In bubble-magnetic and bubble-light mode, a built-in acceleration system allows micromotor speed to be increased up to 3.0 and 1.5 times after application of the magnetic field or light irradiation, respectively. In the bubble-magnetic-light mode, such speed increase can be combined in a single unit for on-demand braking and accelerating systems. Fluid dynamics simulations illustrate that such adaptative behavior and improved propulsion efficiency is produced by a better distribution of the fuel and thus energy propelling the micromotor by activation of the magnetic and/or light engines. The new micromotors described here, which combine multiple engines with functional nanomaterials, hold considerable promise to develop novel nanovehicles with adaptative behavior to perform complex tasks in lab-on-a-chips or dynamic micropatterning applications., Ministerio de Ciencia e Innovación, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

A dual colorimetric-electrochemical microfluidic paper-based analytical device for point-of-care testing of ischemic strokes

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Pacheco Jerez, Marta
  • Gasull, Teresa
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
11 p., A novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual mu PAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated from the ratio between transferrin-bound iron, which was colorimetrically measured, and the total iron-binding capacity, which was electrochemically measured. To this end, a mu PAD was smartly designed, which integrated both colorimetric and electrochemical detection reservoirs, communicating via a microchannel acting as a chemical reactor, and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability of the results due to an independent signal principle and processing. The mu PADs were validated by analyzing a certified reference material, showing excellent accuracy (E-r <= 5%) and precision (RSD <= 2%). Then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05) and no significant differences were found between them (slope 1.0 +/- 0.1 and the intercept 1 +/- 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 mu L of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical mu PAD is a promising ready to use reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic strokes, where the decision-time is crucial for the patient's survival., Comunidad de Madrid, Ministerio de Economía y Competitividad, Agencia de Gestión de Ayudas Universitarias y de Investigación de Cataluña, Unión Europea
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Effect of nanocellulose polymorphism on electrochemical analytical performance in hybrid nanocomposites with non-oxidized single-walled carbon nanotubes

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Sierra Gómez, Tania|||0000-0003-3019-2026
  • Álvarez Sánchez, Miguel A.
  • González Domínguez, José L.
  • Benito, Ana M.
  • Maser, Wolfgang K.
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
10 p., Two cellulose nanocrystals/single-walled carbon nanotube (CNC/SW) hybrids, using two cellulose polymorphs, were evaluated as electrochemical transducers: CNC type I (CNC-I/SW) and CNC type II (CNC-II/SW). They were synthesized and fully characterized, and their analytical performance as electrochemical sensors was carefully studied. In comparison with SWCNT-based and screen-printed carbon electrodes, CNC/SW sensors showed superior electroanalytical performance in terms of sensitivity and selectivity, not only in the detection of small metabolites (uric acid, dopamine, and tyrosine) but also in the detection of complex glycoproteins (alpha-1-acid glycoprotein (AGP)). More importantly, CNC-II/SW exhibited 20 times higher sensitivity than CNC-I/SW for AGP determination, yielding a LOD of 7 mg L?1.These results demonstrate the critical role played by nanocellulose polymorphism in the electrochemical performance of CNC/SW hybrid materials, opening new directions in the electrochemical sensing of these complex molecules. In general, these high-active-surface hybrids smartly exploited the preserved non-oxidized SW conductivity with the high aqueous dispersibility of the CNC, avoiding the use of organic solvents or the incorporation of toxic surfactants during their processing, making the CNC/SW hybrids promising nanomaterials for electrochemical detection following greener approaches., Comunidad de Madrid; Ministerio de Economía y Competitividad de España; CRUE-CSIC; Gobierno de Aragon, Comunidad de Madrid, Ministerio de Economía y Competitividad, Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación, Gobierno de Aragón
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Prussian Blue/Chitosan Micromotors with Intrinsic Enzyme-like Activity for (bio)-Sensing Assays

  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Molinero Fernández, Águeda
  • María Hormigos, Roberto|||0000-0001-8002-3998
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
Prussian Blue (PB)/chitosan enzyme mimetic tubular micromotors are used here for on-the-fly (bio)-sensing assays. The micromotors are easily prepared by direct deposition of chitosan into the pores of a membrane template and in situ PB synthesis during hydrogel deposition. Under judicious pH control, PB micromotors display enzyme mimetic capabilities with three key functions on board: the autonomous oxygen bubble propulsion (with PB acting as a catalase mimic for hydrogen peroxide decomposition), 3,3',5,5'-tetramethylbenzidine (TMB) oxidation (with PB acting as a peroxidase mimic for analyte detection), and as a magnetic material (to simplify the (bio)-sensing steps). In connection with chitosan capabilities, these unique enzyme mimetic micromotors are further functionalized with acetylthiocholinesterase enzyme (ATChE) to be explored in fast inhibition assays (20 min) for the colorimetric determination of the nerve agent neostigmine, with excellent analytical performance in terms of quantification limit (0.30 mu M) and concentration linear range (up to 500 mu M), without compromising efficient micromotor propulsion. The new concept illustrated holds considerable potential for a myriad of (bio)-sensing applications, including forensics, where this conceptual approach remains to be explored. Micromotor-based tests to be used in crime scenes are also envisioned due to the reliable neostigmine determination in unpretreated samples., Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Sensitive monitoring of enterobacterial contamination of food using self-propelled Janus microsensors

  • Pacheco Jerez, Marta|||0000-0001-9546-9108
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Food poisoning caused by bacteria is a major cause of disease and death worldwide. Herein we describe the use of Janus micromotors as mobile sensors for the detection of toxins released by enterobacteria as indicators of food contamination. The micromotors are prepared by a Pickering emulsion approach and rely on the simultaneous encapsulation of platinum nanoparticles for enhanced bubble-propulsion and receptor-functionalized quantum dots (QDs) for selective binding with the 3-deoxy-o-manno-oct-2-ulosonic acid target in the endotoxin molecule. Lipopolysaccharides (LPS) from Salmonella enterica were used as target endotoxins, which upon interaction with the QDs induce a rapid quenching of the native fluorescence of the micromotors in a concentration-dependent manner. The micromotor assay can readily detect concentrations as low as 0.07 ng mL(-1) of endotoxin, which is far below the level considered toxic to humans (275 mu g mL(-1)). Micromotors have been successfully applied for the detection of Salmonella toxin in food samples in 15 min compared with several hours required by the existing Gold Standard method. Such ultrafast and reliable approach holds considerable promise for food contamination screening while awaiting the results of bacterial cultures in a myriad of food safety and security defense applications., Ministerio de Economía y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis

  • Molinero Fernández, Águeda
  • Moreno Guzmán, María
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Procalcitonin (PCT) is a known protein biomarker clinically used for the early stages of sepsis diagnosis and therapy guidance. For its reliable determination, sandwich format magnetic bead-based immunoassays with two di erent electrochemical detection approaches are described: (i) disposable screen-printed carbon electrodes (SPE-C, on-drop detection); (ii) electro-kinetically driven microfluidic chips with integrated Au electrodes (EMC-Au, on-chip detection). Both approaches exhibited enough sensitivity (limit of detection (LOD) of 0.1 and 0.04 ng mL?1 for SPE-C and EMC-Au, respectively; cuto 0.5 ng mL?1), an adequate working range for the clinically relevant concentrations (0.5?1000 and 0.1?20 ng mL?1 for SPE-C and EMC-Au, respectively), and good precision (RSD < 9%), using low sample volumes (25 L) with total assay times less than 20 min. The suitability of both approaches was successfully demonstrated by the analysis of human serum and plasma samples, for which good recoveries were obtained (89?120%). Furthermore, the EMC-Au approach enabled the easy automation of the process, constituting a reliable alternative diagnostic tool for on-site/bed-site clinical analysis., La Caixa, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Paper-based analytical devices for accurate assessment of transferrin saturation in diagnosed clinical samples from ischemic stroke patients

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • DeGregorio Rocasolano, Núria
  • Millán, Mònica
  • Gasull, Teresa
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
7 p., For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ? 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited., Comunidad de Madrid, Ministerio de Economía y Competitividad, Ministerio de Ciencia e Innovación, Agencia de Gestión de Ayudas Universitarias y de Investigación de Cataluña, Unión Europea
e_Buah Biblioteca Digital Universidad de Alcalá
Publicación Artículo científico (JournalArticle)

Electrochemical Microfluidic Micromotors-Based Immunoassay for C-Reactive Protein Determination in Preterm Neonatal Samples with Sepsis Suspicion

  • Molinero Fernández, Águeda
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Online coupling of a micromotor-based immunoassay and a microfluidic electrochemical detection was explored as a new approach for C-reactive protein (CRP) determination in serum and preterm neonatal plasma samples with sepsis suspicion. The approach combines the advantages of micromotors (self-fluid mixing capabilities leading to a faster assay in low sample olumes) and electrochemical microfluidic (flow-controlled ultraminiaturized electrochemical detection, high sensitivity, and low-cost) technologies. Both technologies elegantly meet the point of care testing or bed side device requirements such as low analysis times, miniaturization and simplification, and single use. Anti-CRP functionalized micromotors (anti-CRP-rGO(reduced graphene oxide)/Ni/PtNPs (platinum nanoparticles))-based immunoassay coupled to thin layer Au-based electrochemical microfluidics operating at ?0.20 V under controlled fluidic detection operations (30 ?L min?1) allowed the sensitive (LOD = 0.54 ?g/mL) and accurate CRP determination using very low volume preterm neonatal clinical samples (<10 ?L) in just 8 min of total assay time. These excellent analytical characteristics obtained linked to the full automatization of the immunoassay allowed the fast and accurate determination of CRP in hardly available clinical samples as those coming from preterm infants with suspected sepsis. These results demonstrated the usefulness of the approach which meets the clinical requirements as a future point-of-care device for clinical analysis., Ministerio de Economía y Competitividad, Comunidad Autónoma de Madrid, Fundación “La Caixa”