Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Territorial inequalities, ecological and material footprints of the energy transition: case study of the Cantabrian-Mediterranean Bioregion

  • Felipe-Andreu, Javier
  • Valero, Antonio
  • Valero, Alicia
This study develops a methodology to assess the energy transition’s territorial, ecological and material impacts on regions. As a case study, the methodology is applied to the Cantabrian-Mediterranean Bioregion, a geographical area constituting eight autonomous communities located in the north of Spain. Two energy demand scenarios for 2030 and 2050 were assessed. The 2030 scenario is based on the Spanish government’s planning, and the 2050 scenario constitutes a net-zero emission economy based on electrification. Energy dependence between autonomous communities, energy and raw material needs, and availability are obtained for both scenarios. Results show a high imbalance between energy producer–consumer autonomous communities and an ecological and critical material deficit for the Bioregion. Two alternative scenarios are proposed, one based on self-sufficiency to ensure a balanced energy transition and another based on energy and material efficiency seeking that the ecological and critical material footprints do not surpass the planet’s carrying capacity. The indicators and methodology proposed can be easily replicated elsewhere and help develop more equitable and sustainable territorial planning strategies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Energy and carbon footprint of metals through physical allocation. Implications for energy transition

  • Torrubia, Jorge
  • Valero, Alicia
  • Valero, Antonio
The increasing metal demand driven by energy and digital transition has led to more complex mining operations. To allocate environmental impacts in cases of mining co-production, this study proposes a physical method based on the relative geological scarcity of elements, which provides the basis for an exergy cost allocation. It focuses on calculating the energy and carbon footprint of 51 metals, including 28 co-products, based on available databases. The analysis considers the fuel type, main production stages and the energy footprint of up to 25 chemicals. This study provides new insights into 39 infrequently studied metals. Results show that by using renewable electricity in production, 41 metals can reduce their carbon footprint by up to 50 %. However, key metals such as Fe or Li require additional decarbonization efforts beyond electricity. Only by decarbonizing metal production is possible a renewable infrastructure that can achieve the energy transition goals.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Comparison of Different Numerical Models for Solidification of Paraffin-Based PCMs and Evaluation of the Effect of Variable Mushy Zone Constant

  • Tajik Jamalabad, Milad
  • Cortes, Cristobal
  • Pallarés, Javier
  • Gil, Antonia
  • Arauzo, Inmaculada
The impact of the mushy zone parameter (Amushy) and the chosen numerical model during the solidification of a commercial paraffin-type phase change material (PCM) in a vertical cylinder under T-history conditions was examined through numerical simulations. The cooling process was modeled using three methods implemented in the CFD software ANSYS Fluent 2020 R2: the enthalpy–porosity method, the apparent heat capacity (AHC) method, and a new model proposed by the authors which incorporates heat capacity directly into ANSYS Fluent. To accurately define the boundary conditions, radiative heat transfer between surfaces was taken into account. Furthermore, the influence of the mushy zone parameter on the simulation accuracy and solidification rate was investigated, with the parameter being treated as a function of the liquid fraction. The results indicate that the proposed model aligns closely with experimental data regarding cooling temperature, offering better predictions compared to the other models. It was observed that temperature varies with time but not with position, suggesting that this model more effectively satisfies the lumped system condition—an essential characteristic of the T-history experiment—compared to the other methods. Additionally, the analysis showed that a higher mushy zone parameter enhances the accuracy of simulations and predicts a shorter solidification time; approximately 11% for the E-p and 7% for the AHC model. Using a variable mushy zone parameter based on the liquid fraction also produced similar results, resulting in an increased solidification rate.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Integrated model of a biomass boiler coupled with a Stirling engine

  • Uche, Javier
  • Usón, Sergio
  • Gómez, Juan-Anat
Integration of a Stirling engine in a biomass boiler can be an interesting renewable alternative for the supply of heat and electricity in isolated homes located in areas where local biomass is available and during months when sunlight is low. Since this integration requires a careful coupling of the engine and boiler, an integrated model of these two devices is a relevant issue. In this case, a modular integrated model of a 25 kWth biomass pellet boiler, fire-tube with a cylindrical water jacket, coupled to a 1 kWe free piston Stirling engine is presented. To model the boiler, and take into account the location of the Stirling head, the zonal method was chosen, which allows estimating this temperature from an additional set of surrounding temperatures. For the Stirling engin, a model widely used to evaluate those engines was used. Various software tools have been used to integrate the model sequentially. The integrated model predicts the thermal and electrical production based on different opera-tion parameters, such as the boiler load in 5% fractions of its load from 50 to 100%. The obtained results, which will be validated with the experimental setup, show a maximum output of approximately 600 W for the engine and a decreasing tem-perature profile in the combustion chamber, as a function of the partial load.