Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Real-time optimization of the key filtration parameters in an AnMBR: Urban wastewater mono-digestion vs. co-digestion with domestic food waste

  • Robles Martínez, Ángel
  • Capson-Tojo, G.
  • Ruano García, María Victoria
  • Seco Torrecillas, Aurora
  • FERRER, J.
[EN] This study describes a model-based method for real-time optimization of the key filtration parameters in a submerged anaerobic membrane bioreactor (AnMBR) treating urban wastewater (UWW) and UWW mixed with domestic food waste (FW). The method consists of an initial screening to find out adequate filtration conditions and a real-time optimizer applied to a periodically calibrated filtration model for minimizing the operating costs. The initial screening consists of two statistical analyses: (1) Morris screening method to identify the key filtration parameters; (2) Monte Carlo method to establish suitable initial control inputs values. The operating filtration cost after implementing the control methodology was (sic)0.047 per m(3) (59.6% corresponding to energy costs) when treating UWW and 0.067 per m(3) when adding FW due to higher fouling rates. However, FW increased the biogas productivities, reducing the total costs to (sic)0.035 per m(3). Average downtimes for reversible fouling removal of 0.4% and 1.6% were obtained, respectively. The results confirm the capability of the proposed control system for optimizing the AnMBR performance when treating both substrates. (C) 2018 Elsevier Ltd. All rights reserved., This research work was possible thanks to financial support from Generalitat Valenciana (project PROMETEO/2012/029) which is gratefully acknowledged. Besides, support from FCC Aqualia participation in INNPRONTA 2011 IISIS IPT-20111023 project (partially funded by The Centre for Industrial Technological Development (CDTI) and from the Spanish Ministry of Economy and Competitiveness) is gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A new strategy to maximize organic matter valorization in municipalities: combination of urban wastewater with kitchen food waste and its treatment with AnMBR technology

  • Moñino Amorós, Patricia
  • Jiménez, E.
  • Giménez, J.B.
  • Seco, A.
  • FERRER, J.
  • Aguado García, Daniel|||0000-0002-6417-366X
  • Barat, Ramón|||0000-0003-0484-3614
[EN] The aim of this study was to evaluate the feasibility of treating the kitchen food waste (FW) jointly with urban wastewater (WW) in a wastewater treatment plant (WWTP) by anaerobic membrane technology (AnMBR). The experience was carried out in six different periods in an AnMBR pilot-plant for a total of 536 days, varying the SRT, HRT and the food waste penetration factor (PF) of food waste disposers. The results showed increased methane production of up to 190% at 70 days SRT, 24 hours HRT and 80% PF, compared with WW treatment only. FW COD and biodegradability were higher than in WW, so that the incorporation of FW into the treatment increases the organic load and the methane production and reduces sludge production (0.142 vs 0.614 kg VSSkg removed COD-1, at 70 days SRT, 24 hours HRT and 80% PF, as compared to WW treatment only)., This research work was possible thanks to financial support from Generalitat Valenciana (project PROMETE0/2012/029) which is gratefully acknowledged. Besides, support from FCC Aqualia participation in INNPRONTA 2011 IISIS IPT-20111023 project (partially funded by The Centre for Industrial Technological Development (CDTI) and from the Spanish Ministry of Economy and Competitiveness) is gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Designing an AnMBR-based WWTP for energy recovery from urban wastewater: The role of primary settling and anaerobic digestion

  • Pretel, R.
  • Durán Pinzón, Freddy
  • Robles Martínez, Ángel
  • Ruano García, María Victoria
  • Ribes Bertomeu, Jose
  • FERRER, J.
  • Serralta Sevilla, Joaquín|||0000-0001-5015-0689
The main objective of this paper is to assess different treatment schemes for designing a submerged anaerobic membrane bioreactor (AnMBR) based WWTP. The economic impact of including a primary settling (PS) stage and further anaerobic digestion (AD) of the wasted sludge has been evaluated. The following operating scenarios were considered: sulphate-rich and low-sulphate urban wastewater (UWW) treatment at 15 and 30 ºC. To this aim, the optimum combination of design/operating parameters that resulted in minimum total cost (CAPEX plus OPEX) for the different schemes and scenarios was determined. The AnMBR design was based on both simulation and experimental results from an AnMBR plant featuring industrial-scale hollow-fibre membranes fed with UWW from the pre-treatment of a municipal WWTP located in Valencia (Spain). AnMBR without PS and AD was identified as the most economic option for an AnMBR-based WWTP treating low-sulphate UWW (minimum cost of 0.05 per m3 and a maximum surplus energy of 0.1 kW h per m3), whilst AnMBR with PS and AD was the optimum option when treating sulphate-rich UWW (minimum cost of 0.05 per m3 and a maximum surplus energy of 0.09 kW h per m3)., This research work was possible thanks to projects CTM2011-28595-C02-01/02 (funded by the Spanish Ministry of Economy and Competitiveness jointly with the European Regional Development Fund and Generalitat Valenciana GVA-ACOMP2013/203) and FCC Aqualia INNPRONTA IISIS IPT-20111023 (partially funded by the Centre for Industrial Technological Development (CDTI), and supported by the Spanish Ministry of Economy and Competitiveness).