Publicación Reseña (Review)

Breaking the boundaries in spectrometry. Molecular analysis with atomic spectrometric techniques

  • Resano, M.
  • Aramendía, M.
  • Nakadi, F.V.
  • García-Ruiz, E.
  • Alvarez-Llamas, C.
  • Bordel, N.
  • Pisonero, J.
  • Bolea-Fernández, E.
  • Liu, T.
  • Vanhaecke, F.
Since the development of atomic spectrometry, trace element and isotopic analysis has been mainly based on the monitoring of atomic spectra and monoionic species. However, according to the literature and considering the current instrumental developments, it seems that some of the remaining challenges in this field can be mitigated via the measurement of molecular spectra or of polyatomic ions. This review discusses recent advances in three of the most important atomic techniques (laser-induced breakdown spectrometry, high-resolution continuum source atomic absorption spectrometry and inductively coupled plasma mass spectrometry) and how the monitoring of such molecules or polyatomic ions containing the target analyte enables attaining better selectivity and opens new ways to determine non-metals and to obtain isotopic information.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination: Via high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study

  • Garde, Raúl
  • Venancio Nakadi, Flávio
  • García-Ruiz, Esperanza
  • Resano, Martín
This manuscript explores the advantages of using multi-signal calibration approaches for the determination of non-metals via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS), targeting Br as an example. Besides multi-energy calibration (MEC), a novel approach deriving from it, multi-energy ratios (MER), is introduced and compared under different conditions. This approach makes use of the same data but in a different way, such that no linear regression is performed; instead, ratios are calculated. This article investigates the potential errors deriving from the use of amounts of spike dissimilar from the sample content, leading to too high (close to 1) or too low (close to 0) slopes/ratios, setting the best conditions in terms of precision and accuracy for the intended determination in the range of approx. 0.5 to 0.6. Also, situations where the use of MER could be recommended over MEC are identified: namely when only a few transitions of sufficient sensitivity and free from overlaps are available or else, many transitions but of similar sensitivity, which may occur when HR CS GFMAS is deployed. Otherwise, for multiple transitions covering a wider sensitivity range, use of linear regression and thus, of MEC, seems favoured, as a better precision can be achieved. The calculation of limits of detection and quantification for both approaches is also discussed. It is finally further demonstrated that these multi-signal strategies help in solving chemical interferences, which very often hamper the determination of non-metals with HR CS GFMAS, and they do so in a simple way, without the need for laborious work or for the preparation of several standards and sample aliquots, therefore making them a very intriguing option when this technique is deployed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events

  • Resano, M.
  • Aramendia, M.
  • Garcia-Ruiz, E.
  • Bazo, A.
  • Bolea-Fernandez, E.
  • Vanhaecke, F.
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Determination of Cu in blood: Via direct analysis of dried blood spots using high-resolution continuum source graphite furnace atomic absorption spectrometry

  • García-Poyo M.C.
  • Pécheyran C.
  • Rello L.
  • García-González E.
  • Alonso Rodríguez S.
  • Venancio Nakadi F.
  • Aramendía M.
  • Resano M.
The performance of state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) instrumentation and four novel devices to produce dried blood spots of perfectly defined volumes is evaluated with the aim of developing a simple, direct method for the determination of Cu in blood samples. In all cases, it is feasible to obtain accurate quantitative information using any of the four devices tested (Mitra, HemaXis DB10, Capitainer qDBS and HemaPEN) via simple external calibration with aqueous standards. One of the main differences in the performance of such devices is related to the blanks obtained, such that HemaXis DB10 and HemaPEN are preferred when abnormally low Cu levels (500 µg L-1 or lower), associated with some diseases, need to be determined. The results prove that accurate values with RSD values below 10% can be achieved for these devices even for such Cu levels, while for Capitainer qDBS and, to a higher extent, for Mitra, blank variations will ultimately increase the uncertainty. It is important to stress that analysis of four real samples using both venipuncture and all the DBS specimens showed a very good agreement. Thus, the approach proposed could be readily applied, such that patients with disorders requiring Cu control can prepare their own samples and submit them via postal mail to labs for HR CS GFAAS direct and fast analysis. © The Royal Society of Chemistry.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cu fractionation, isotopic analysis, and data processing via machine learning: new approaches for the diagnosis and follow up of Wilson's disease via ICP-MS

  • García-Poyo, M. Carmen
  • Bérail, Sylvain
  • Ronzani, Anne Laure
  • Rello, Luis
  • García-González, Elena
  • Nakadi, Flávio V.
  • Aramendía, Maite
  • Resano, Javier
  • Resano, Martín
  • Pécheyran, Christophe
Information about Cu fractionation and Cu isotopic composition can be paramount when investigating Wilson's disease (WD). This information can provide a better understanding of the metabolism of Cu. Most importantly, it may provide an easy way to diagnose and to follow the evolution of WD patients. For such purposes, protocols for Cu determination and Cu isotopic analysis via inductively coupled plasma mass spectrometry were investigated in this work, both in bulk serum and in the exchangeable copper (CuEXC) fractions. The CuEXC protocol provided satisfactory recovery values. Also, no significant mass fractionation during the whole analytical procedure (CuEXC production and/or Cu isolation) was detected. Analyses were carried out in controls (healthy persons), newborns, patients with hepatic disorders, and WD patients. While the results for Cu isotopic analysis are relevant (e.g., δ65Cu values were lower for both WD patients under chelating treatment and patients with hepatic problems in comparison with those values obtained for WD patients under Zn treatments, controls, and newborns) to comprehend Cu metabolism and to follow up the disease, the parameter that can help to better discern between WD patients and the rest of the patients tested (non-WD) was found to be the REC (relative exchangeable Cu). In this study, all the WD patients showed a REC higher than 17%, while the rest showed lower values. However, since establishing a universal threshold is complicated, machine learning was investigated to produce a model that can differentiate between WD and non-WD samples with excellent results (100% accuracy, albeit for a limited sample set). Most importantly, unlike other ML approaches, our model can also provide an uncertainty metric to indicate the reliability of the prediction, overall opening new ways to diagnose WD.